background image

6

Operating the appliance

These instructions apply to several appliance variants. It is 

possible that individual features are described which do not 

apply to your appliance.

Note: 

Switch on the extractor hood when you start cooking and 

switch it off again several minutes after you have finished 

cooking. This is the most effective way of removing the kitchen 

fumes.

Control panel

Setting the fan

Switching on

Press the 

#

, 2

9

, 3

8

 or 

˜

 button.

Switching off

Press the 

#

 button.

Note: 

If fan level 2 or 3 is switched on, press the 

#

 button 

twice.

Intensive setting

You can use the intensive setting if there is a large build-up of 

odours and fumes/vapours.
Press the 

˜

 button.

Intensive mode is activated.

Notes

The intensive mode run time is limited to 6 minutes.

Once 6 minutes has elapsed, the appliance switches back to 

the fan level that was previously selected.

Intensive mode can be activated when the appliance is 

switched off; once 6 minutes has elapsed, the appliance 

switches itself off again.

Fan run-on

With the fan run-on, the appliance continues to run at the level 

that was previously set and switches off automatically after 

30 minutes.

1.

Set the fan level.

2.

Press and hold the 2

9

 button.

Fan run-on mode is activated. The button for this level flashes 

green.

Interval ventilation

With interval ventilation, the ventilation system switches on 

automatically at the lowest level for 10 minutes every hour. The 

interval ventilation switches off after 24 hours.

Switching on

Press and hold the 3

8

 button.

The interval ventilation is activated. The 

#

 button flashes.

Switching off

Press and hold the 3

8

 button or press the 

#

 button.

Lighting

The lighting can be switched on and off independently of the 

ventilation system.
Press the 

6

 button.

The lighting is switched on.

Setting the brightness

Press and hold the 

6

 button until the desired brightness is 

reached.

Saturation indicator

If F is lit, this means that the integrated filters are saturated:
Lit permanently: clean the metal grease filter
For instructions on how to clean metal grease filters, refer to the 

section 

Cleaning and maintenance

.

Resetting the saturation indicator

1.

Switch off the appliance.

2.

Press and hold the 

#

 button for 3 seconds.

The saturation indicator is reset. F goes out.

Explanation

6

Light on/off

#

Fan off/fan level 1

2

9

Fan level 2/fan run-on

3

8

Fan level 3/interval ventilation

˜

Intensive mode

F

Saturation indicator

)

Содержание D57ML6.N0

Страница 1: ...en Instruction manual Extractor hood D55ML6 N0 D57ML6 N0 D58ML6 N0...

Страница 2: ......

Страница 3: ...l This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they ar...

Страница 4: ...ickly Never leave hot fat or oil unattended Never use water to put out burning oil or fat Switch off the hotplate Extinguish flames carefully using a lid fire blanket or something similar Risk of fire...

Страница 5: ...require it Clean and if required replace the filter at regular intervals in order to increase the effectiveness of the ventilation system and to prevent the risk of fire Put the lid on to reduce cooki...

Страница 6: ...switches off automatically after 30 minutes 1 Set the fan level 2 Press and hold the 29 button Fan run on mode is activated The button for this level flashes green Interval ventilation With interval v...

Страница 7: ...etal mesh grease filters These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Risk of fire Grease deposits...

Страница 8: ...ut the activated charcoal filter 5 Clean the appliance Fitting the activated charcoal filter only in circulating air mode 1 Insert the activated charcoal filter into the extractor hood 2 Guide the act...

Страница 9: ...ppliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service LED lights Defective LED lights must only be replaced by the...

Страница 10: ...the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the wa...

Страница 11: ......

Страница 12: ...www neff international com Register your product online 9001018782 9001018782 980525 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen GERMANY...

Отзывы: