Imp
ort
Ap
plia
nce
s.c
om
THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.
General information
en
13
Electrical connection
:
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
The required connection data can be found on the
rating plate inside the appliance; to do this, remove the
metal mesh grease filter.
Length of the connecting cable: Approx. 1.20 m
This appliance complies with the EC interference
suppression regulations.
:
Warning – Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug of the mains power cable must be
easily accessible after installation of the appliance. If
this is not possible, an all-pole isolating switch must be
integrated into the permanent electrical installation
according to the conditions of overvoltage category III
and according to the installation regulations.
The permanent electrical installation must only be wired
by a professional electrician. We recommend installing
a residual-current circuit breaker (RCCB) in the
appliance's power supply circuit.
Preparing the housing
■
The extractor hood must be installed on the lower
edge so that it is flush with the housing.
■
The housing must cover the entire cooking area.
■
The max. weight of the extractor hood is 15 kg.
Appliance dimensions and safety clearances
■
Take the appliance's dimensions into account.
■
Comply with the safety clearances.
If the installation instructions for the gas cooking
appliances specify a different distance, the largest
distance must always be provided for.
The surround must still be sturdy after the cut-outs have
been made.
To install the extractor hood in a surround, the extractor
hood must be provided with the following dimensions:
Note:
All walls of the surround must be at least 15 mm
thick.
Extractor hood 53 cm wide, with one or two motors:
Extractor hood 73 cm wide, with one or two motors:
Width
500-3 mm (appliance width of 53 cm)
Width
700-3 mm (appliance width of 73 cm)
Depth
352-3 mm
Height
min. 160 mm (appliance with two motors)
Wall thickness
16 mm
PLQ
PLQ
PLQ