background image

Installation instructions

 en

11

 12.4 Secure installation

Follow these safety instructions when in-

stalling the appliance.

WARNING ‒ Risk of poisoning!

Risk of poisoning from flue gases being

drawn back in. Room-air-dependent heat-pro-

ducing appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or

water heaters) obtain combustion air from the

room in which they are installed and dis-

charge the exhaust gases into the open

through an exhaust gas system (e.g. a chim-

ney). With the extractor hood switched on, air

is extracted from the kitchen and the adjacent

rooms. Without an adequate supply of air, the

air pressure falls below atmospheric pressure.

Toxic gases from the flue or the extraction

shaft are sucked back into the living space. 

Always ensure adequate fresh air in the

room if the appliance is being operated in

exhaust air mode at the same time as a

room-air-dependent heat-producing appli-

ance is being operated.

It is only possible to safely operate the ap-

pliance if the pressure in the room in which

the heating appliance is installed does not

drop more than 4 Pa (0.04 mbar) below at-

mospheric pressure. This can be achieved

whenever the air needed for combustion is

able to enter through openings that cannot

be sealed, for example in doors, windows,

incoming/exhaust air wall boxes or by

other technical means. An incoming/ex-

haust air wall box alone does not ensure

compliance with the limit.

In any case, consult your responsible chim-

ney sweep. They are able to assess the

house's entire ventilation setup and will

suggest the suitable ventilation measures

to you.

Unrestricted operation is possible if the ap-

pliance is operated exclusively in circulat-

ing-air mode.

Risk of poisoning from flue gases being

drawn back in.

If an extractor hood with an open-flued heat

production source is installed, the power

supply for the extractor hood must be

provided with a suitable safety switch.

Risk of poisoning from flue gases being

drawn back in.

Do not emit the exhaust air into a smoke or

exhaust gas flue that is in operation.

Do not emit the exhaust air into a shaft that

is used to ventilate installation rooms for

heat-producing appliances.

If the exhaust air is to be conveyed into a

smoke or exhaust gas flue, you must obtain

the consent of the heating engineer re-

sponsible.

WARNING ‒ Risk of suffocation!

Children may put packaging material over

their heads or wrap themselves up in it and

suffocate.

Keep packaging material away from chil-

dren.

Do not let children play with packaging ma-

terial.

WARNING ‒ Risk of fire!

Grease deposits in the grease filter may catch

fire.

The specified safety clearances must be

complied with in order to prevent a build-up

of heat.

Observe the specifications for your cooking

appliances. If the installation instructions for

the cooking appliances specify a different

clearance, the larger of the two must al-

ways be provided for. If gas hobs and elec-

tric hobs are operated together, the largest

specified clearance applies.

The grease deposits in the grease filter may

catch fire.

Never work with naked flames close to the

appliance (e.g. flambéing).

Do not install the appliance near a heat-

producing appliance for solid fuel (e.g.

wood or coal) unless a closed, non-remov-

able cover is present. There must be no fly-

ing sparks.

WARNING ‒ Risk of injury!

Components inside the appliance may have

sharp edges.

Wear protective gloves.

Содержание D55MH56N0B/01

Страница 1: ...Extractor hood User manual and installation instructions D55MH 6N0 D57MH56N0...

Страница 2: ...installation location Only use this appliance For extracting cooking vapour in private households and in enclosed spaces in a domestic environment up to an altitude of max 2000 m above sea level Do n...

Страница 3: ...rease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the appliance e g flamb ing Do not install the...

Страница 4: ...Service WARNING Risk of electric shock Penetrating moisture may cause an electric shock Do not use wet sponge cloths 2 Avoiding material damage ATTENTION Condensate may cause corrosion damage To preve...

Страница 5: ...The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room If t...

Страница 6: ...Note You can switch on the intensive mode directly in off mode Once the six minutes has elapsed the appli ance is switched off again 7 5 Switching on the lighting The lighting can be switched on and...

Страница 7: ...nts 2 Clean using a damp sponge cloth and hot soapy water 3 Dry with a soft cloth 8 4 Removing the grease filter WARNING Risk of injury The filter cover may swing out Open the filter cover slowly Take...

Страница 8: ...tting grease filters ATTENTION Falling grease filters may damage the hob below Grip below the grease filter with one hand 1 Fit the grease filters 2 Fold the grease filters upwards and engage the lock...

Страница 9: ...an only 9 2 Malfunctions Fault Cause and troubleshooting The appliance is not working The mains plug of the power cord is not plugged in Connect the appliance to the power supply The circuit breaker i...

Страница 10: ...be found in the enclosed Customer Service directory or on our website 11 1 Product number E Nr and production number FD You can find the product number E Nr and the pro duction number FD on the applia...

Страница 11: ...to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode Risk of poisoning from flue gases being drawn back in If an extractor hood with an open flu...

Страница 12: ...ion In order to safely connect the appliance to the elec trical system follow these instructions WARNING Risk of electric shock It must always be possible to disconnect the appliance from the electric...

Страница 13: ...air mode The appliance must only be operated when it is se curely installed and the pipework is connected 12 11 Installation Checking the unit 1 Check whether the fitted unit is level and has suffi ci...

Страница 14: ...1 Position the filter retainer correctly on the motor and turn it to the front until it clicks into place 2 Slide the odour filter into the filter retainer Installing the appliance 1 Insert the applia...

Страница 15: ...pe connector 2 Connect the pipe to the opening on the fitted unit 3 Screw the air guide grille to the fitted unit 4 Seal the joints Connecting to the power supply 1 Insert the mains plug into the prot...

Страница 16: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001604440 9001604440 030222 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...

Отзывы: