![Neets 312-0003 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/neets/312-0003/312-0003_manual_3847356017.webp)
Doc. no: 312-0003-002-001 Rev 1.06
Page 16 of 19
Examples for use of the protocol
–
continued
Here we will try to set up the audio amplifier to have some default parameters, turn on, mute on, mute off, and
turn off again.
Default parameters:
x
Default input: Input 2
x
Default power: off
x
Default volume: 20
To set up above default parameters (and leave the rest factory default) send the following commands to the
audio amplifier (NOTE: <CR> is the 0x0D HEX value for
C
arriage
R
eturn):
x
Send:
NEAMP1,
FACTORYDEFAULT=ALL<CR>
x
Response:
NEAMP1,
OK <CR>
x
Send:
NEAMP1,
INPUT=2<CR>
x
Response:
NEAMP1,
OK <CR>
x
Send:
NEAMP1,
POWER=OFF<CR>
x
Response:
NEAMP1,
OK <CR>
x
Send:
NEAMP1,
VOL=20<CR>
x
Response:
NEAMP1,
OK <CR>
x
Send:
NEAMP1,
SAVE=TRUE<CR>
x
Response:
NEAMP1,
OK <CR>
Now we want to turn on the unit, send the following commands to the audio amplifier (NOTE: <CR> is the 0x0D
HEX value for
C
arriage
R
eturn):
x
Send:
NEAMP1,
POWER=ON<CR>
x
Response:
NEAMP1,
OK <CR>
Now we want to mute and on mute the audio amplifier, send the following commands to the audio amplifier
(NOTE: <CR> is the 0x0D HEX value for
C
arriage
R
eturn):
x
Send:
NEAMP1,
MUTE=ON<CR>
x
Response:
NEAMP1,
OK <CR>
To get out of mute send:
x
Send:
NEAMP1,
MUTE=OFF<CR>
x
Response:
NEAMP1,
OK <CR>
Now we want to turn off the unit, send the following commands to the audio amplifier (NOTE: <CR> is the 0x0D
HEX value for
C
arriage
R
eturn):
x
Send:
NEAMP1,
POWER=OFF<CR>
x
Response:
NEAMP1,
OK <CR>
Содержание 312-0003