Neets Control LiMa Скачать руководство пользователя страница 3

Page 3 of 12

Important Safety Instructions

Caution:

Read these instructions. 
Read and understand all safety and operating instructions before using the equipment. 
Keep these Instructions. 
The safety instructions should be kept for future reference.  
Heed all warnings. 
Follow all warnings and instructions marked on the equipment or in the user information.  
Avoid attachments. 
Do not use tools or attachments that are not recommended, as they may be hazardous.

Warning!:

• This equipment should be operated only from the included power supply. 
•  To remove power from the equipment safely, remove all power cords from the rear of the equipment, or the  

desktop power module (if detachable), or from the power source receptacle (wall plug). 

•  Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or 

against them. 

•  Do not defeat the safety purpose of a polarized or grounding-type plug. A polarized plug has two blades with one 

wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the 
third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet.

• Unplug this apparatus during lightning storms or when unused for long periods of time.
•  Refer all servicing to qualified service personnel. There are no user-serviceable parts inside. To prevent the risk of 

shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to 
dangerous voltage or other hazards. Contact your local Neets reseller or distributor.

•  If the equipment has slots or holes in the enclosure, these are provided to prevent overheating of sensitive  

components inside. These openings must never be blocked by other objects. 

• Do not use this equipment near water. 
•  To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled 

with liquids.

•  Unplug the product before cleaning. Clean only with a dry cloth and not cleaning fluid or aerosols. Such products 

could enter the unit and cause damage, fire, or electric shock. Some substances may also mar the finish of the 
product.

FCC Class A Notice:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. Operation is subject to the following two conditions: 

1. This device may not cause harmful interference. 
2.  This device must accept any interference received, including interference that may cause undesired operation. 

The Class A limits are designed to provide reasonable protection against harmful interference when the  
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference, in which case the user will be required to correct the interference at his own expense.

FCC regulations state that any unauthorized changes or modifications to this equipment, not expressly approved by 

the manufacturer, could void the user’s authority to operate this equipment.

The lightning bolt triangle is used to alert the user to the presence of uninsulated “dangerous  
voltages” within the unit’s chassis that may be of sufficient magnitude to constitute a risk of electric 
shock to humans.

The exclamation point triangle is used to alert the user to presence of important operating and  
service instructions in the literature accompanying the product.

!

Содержание LiMa

Страница 1: ...Neets Control LiMa Installation Manual ...

Страница 2: ...r notice Questions AFTER reading this manual can be addressed to your local distributor or Neets A S Langballe 4 8700 Horsens Denmark by E Mail Support Neets dk or you may use our contact form at www neets dk Revision list This document has the following revision changes Author Date Description Pages Rev TBB 09 08 2018 First release All 1 00 What is in the box When you open the box it will contain...

Страница 3: ...omponents inside These openings must never be blocked by other objects Do not use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture and objects filled with liquids Unplug the product before cleaning Clean only with a dry cloth and not cleaning fluid or aerosols Such products could enter the unit and cause damage fire or electric...

Страница 4: ...rs other AV devices with feedback functionality 2 General Purpose I O ports Used for input output control of relays switches and sensors 2 Built in low voltage relays Used for contolling external devices such as electrical screens Ethernet port Used for controlling 10 LAN and 8 Neets extension devices and connection to Central Control and Project Designer as well as access to graphical user interf...

Страница 5: ...output No Max voltage load 24 VDC Max current 0 5 A Connector 3 pin screw block Relay Output Voltage max 30 VDC Current max 0 5 A Connector 2 pin screw block Network LAN Speed 10 100 Mbit Duplex modes Half or Full DHCP Default off Default IP 192 168 254 252 Default gateway 192 168 1 1 Default subnet mask 255 255 255 0 PoE input Compliance 802 3af 802 3at 802 3af PD mode A B PD Class 0 802 3af 4 80...

Страница 6: ...on a ceiling with the included self tapping screws Unpack the unit place the unit on the surface where it is to be mounted and screw the two screws through the holes in the top as shown below The unit also can be mounted in a 19 inch standard rack using the Neets Rack Shelf Part number 306 0017 See separate manual for installation instructions designed in Denmark Neets Control LiMa control Config ...

Страница 7: ...the I Os When an IO is configured as input the yellow LED marked in will illuminate when the input is high and turn off when the input is low The green LED marked out will remain off When an IO is configured as output the green LED marked out will illuminate when the output is high and turn off when the output is low The yellow LED marked in will remain off Connection and Controls Front Number Des...

Страница 8: ...r about 1mm by using your finger tip Release again and it will slide out REMEMBER to remove power from unit power down before re moving uSD card Power and Error Indication The on LED will show the current status of the unit Green Neets Control LiMa is on and running normally Blue Neets Control LiMa is starting Flashing red The Neets Control LiMa is in error mode see section Error indication on pag...

Страница 9: ...plate R G T2 R2 G T1 R1 PoE IN When used as RS 232 transmit port Connect the device to T1 R1 and GND as shown here above When used as single IR port Connect the IR emitter to T1 white striped wire and GND as shown above When used as dual IR port Connect the IR1 emitter to T1 white striped wire and black wire on IR1 emitter to IR2 emitter white striped wire and black wire from IR2 emitter to GND as...

Страница 10: ...tionality The LAN connector is used to connect the LiMa to the local area network The LiMa has Power over Ethernet functionality built into the LAN interface connector You must connect the LiMa to your LAN if you are using any of the LAN features of the product The port features auto MDI X which means that you can connect the LAN port directly to other devices without the need for a LAN switch The...

Страница 11: ... REV1 G T2 R2 G T1 R1 PoE IN 310 0305 002 003 REV2 Silkscreen Bottom plate PN 310 0305 www neets dk Relays 1 2 3 4 G PWR NCL NDA NEB LAN I O ports G 1 2 4 3 G 5 6 8 7 G T2 R2 G T4 T5 G T1 R1 G T3 R3 PoE IN PoE OUT Relays 1 2 3 4 G PWR NCL NDA NEB LAN I O ports G 1 2 4 3 G 5 6 8 7 G T2 R2 G T4 T5 G T1 R1 G T3 R3 PoE IN PoE OUT 310 0305 002 003 REV2 Silkscreen Bottom plate PN 310 0305 www neets dk R...

Страница 12: ...efore reconnecting the power again Unexpected Error Turn off the power to the Control System for 20 seconds before turning the power on again If the error is not resolved contact Neets or your local distributor No contact to Neets network unit Check to confirm that the serial number used in Project Designer matches the Neets extension unit Check the network or RS 232 connection from the Control Sy...

Отзывы: