09-05-2022 13:00
User manual
https://cdn.nedis.com/manuals/html/WIFIACMB3WT9/?_gl=1*1fr8j43*_ga*MTA0ODQzOTI0OS4xNjMzMzU1MjI3*_ga_49LWESJ80M*MTY1Mj…
12/17
to switch between high and low fan speed
operation.
In DRY mode, it is not possible to switch between
fan speed operation.
Up button B6
Increase values.
Down button B7
Decrease values.
Sleep button B8
Activate sleep mode. Only works in COOL mode.
After one hour the set temperature increases 1 °C
and again after 2 hours.
Mode button B9
Repeatedly press the mode button the select the
mode: FAN / DRY (dehumidifying) / COOL.
Power button B10
Switch the product on or off.
Frost protection function
The product automatically enters the frost protection status if the temperature of the
exhaust pipe is too low (only works in COOL and DRY mode).
The product automatically reverts to the normal operation if the temperature of the exhaust
pipe rises to a certain temperature.
Protection function of the compressor
To increase the lifetime of the compressor, it has a 3 minute delay booting protection
function after the compressor is switched off.
The over ow protection function
If water exceeds the warning level, the product emits a tone, and the ‘water full’ indicator
starts ashing.
(See next paragraphs how to empty the water reservoir of the product.)
Manual drainage
The FULL indicator
B
2
ashes and the product emits an alarm sound to indicate that the
water reservoir is full.
EN