6.5.1 Tightening torques for nuts and bolts
The tightening torques M, for bolts with ISO metric thread, given in the table are applicable in the following con-
ditions:
• Hexagonal head UNI 5737 type screws, cylindrical head UNI 5931 and UNI 6107 type screws, in normal condi-
tions in which they are supplied.
• Tightening torques must be applied slowly using a torque wrench.
While maintaining the same pre-load values, tightening torques must be modified as described below in the fol-
lowing cases:
• Increased by 5% for wide-head UNI 5712 screws.
• Reduced by 10% for zinc-plated oiled screws.
• Reduced by 20% for phosphor-coated oiled screws.
• Reduced by 10% if the screw is tightened with an impulse tightener.
d x pitch [mm]
S r [mm2]
8.8 M [Nm]
10.9 M [Nm]
12.9 M [Nm]
6 x 1
20,1
1. 10,4
2. 15,3
3. 17,9
7 x 1
28,9
17,2
25
30
8 x 1,25
36,6
25
37
44
10 x 1,5
58
50
73
86
12 x 1,75
84,3
84,3
127
148
14 x 2
115
115
115
115
16 x 2
157
214
314
368
18 x 2,5
192
306
435
509
20 x 2,5
245
432
615
719
22 x 2,5
303
592
843
987
24 x 3
353
744
1060
1240
27 x 3
459
1100
1570
1840
30 x 3,5
561
1500
2130
2500
30
Содержание NCF 120/15
Страница 1: ...User Manual Fans NCF NCF fan Original user manual EN USER MANUAL 2022 09 05 2130187 02 EN ...
Страница 3: ...NCF fan Declaration of Conformity 4 Figures 6 English 11 3 ...
Страница 8: ...NCF fan Example of lifting NCF fans 7 Minimum installa on distances with inlet duct 8 8 ...
Страница 10: ...NCF fan OUTDOOR INSTALLATIONS Leave a bend on the cable to prevent water from entering the motor 11 10 ...
Страница 34: ...www nederman com Individual Serial number ...