L-PAK 150/250 Advanced
EN
10
temperature has not gone below 90°C. The unit goes into Off mode. Correct
the problem and press ‘OK’ to reset the alarm.
NOTE!
When Alarm Fan Hi Temp is activated, Alarm output is also activated
until the temperature has gone below 90°C, see section
6.7. Alarm output
..
Alarm Fan Hi Temp
Unit Off
Time when
fault occured
Reset OK ==>
ESC
OK
5.3.2
Motor Protector Activated
The motor is overheated. Correct the problem, and press ‘OK’ to reset the
warning.
Motor Protector
Activated
Time when fault
occured
Reset OK ==>
ESC
OK
5.3.3
Low Pressure CAS
The compressed air level is low. When the accurate pressure is established,
press ‘OK’ to reset the warning.
This warning is only shown when the Compressed Air Switch (CAS) is installed.
Low Pressure
CAS < 3Bar
Time when fault
occured
Reset OK ==>
ESC
OK
6
PLC settings
6.1
Find a parameter and set its value
Do the following to find a parameter and set its value:
L-PAK
Off
TimeToService
2000Hour
ESC
OK
1.
From the PLC status screen, press to go to the unit’s date and time
screen.
Su 00:00
2012-01-01
ESC
OK