GB
GB
Adjustment of time and date
Choose Set Clock with
5
or
6
press
OK
.
1. The cursor shows the day of the week . The charac-
ter flashes when selected.
2. Change weekday with
5
or
6
.
3. Move the cursor to the next position with
3
or
4
.
4. Make any other necessary setting as in 2 and 3
above.
5. Confirm the change with
OK.
Adjustment of parameters
Choose parameter with
5
or
6
press
OK.
Adjustable parameter for the running time,
for more
information, see page 7
MI can be changed when another service interval is
required.
1. Press
OK.
2. Step with
3
or
4
to the character to be changed.
3. Select an appropriate value with
5
or
6
.
4. Confirm the change with
OK.
MN is the time remain-
ing until the service alarm is activated.
OT is the total running time since the system was
started.
The following WeekTim settings are example of
adjustments to the weekly timer´s default setting,
see page 7 for more information.
Setting weekly time 1, Monday - Friday mornings.
1. Press
OK.
2. D = MTWTF are the weekdays the setting is to apply
to. Move the cursor to the weekday to be changed
with
3
or
4
.
3. Activate the appropriate weekday with
5
or
6
.
4. Step forward with
4
to the next day to be changed.
5. Select an appropriate value with
5
or
6
.
6. Step forward with
4
to the time character to be
changed, to set the
ON
time.
7. Select an appropriate value with
5
or
6
.
8. Proceed until the time you want is shown.
9. Repeat the same procedure for the
OFF
time.
10. Confirm the changes with
OK.
Setting weekly timer time 2, Monday - Friday after-
noons.
The settings are made according to previous section.
Settting weekly timer time 3, Saturday - Sunday.
The settings are made according to previous section.
Setting the time before idling.
NOTE! Time should no be adjusted.
6
WeekTim 1
D = MTWTF- -
On = 07:00
Off = 12:00
ESC
OK
PLC-8
WeekTim 2
D = MTWTF- -
On = 13:00
Off = 16:00
ESC
OK
PLC-9
WeekTim 3
D = -----SS
On = --:--
Off = --:--
ESC
OK
PLC-10
DIR
T = 12:00s
Ta = 00:00
ESC
OK
PLC-11
Mo 09:00
2004-01-29
ESC
OK
PLC-2
Stop
Set Param
Setup..
Prg Name
ESC
OK
PLC-3
>
Set Clock
Mo 15:30
YYYY-MM-DD
2003-01-27
ESC
OK
PLC-4
>
Stop
Set Param
Set Clock
Prg Name
ESC
OK
PLC-5
>
H-Meater
MI = 2000h
MN = 2000h
OT = 0h
ESC
OK
PLC-6
>