Preface 

This manual is part of the service documentation for Nedap Velos. Reference is also made to other 
manuals that are part of the Nedap Velos documentation. For an overview of available Nedap Velos 
manuals see the manual “Nedap Velos General Description”, or visit the Nedap Agri website 
www.nedap-agri.com.   

Introduction 

The Velos VP1006 is used for identification of animals for feeding, weighing, milking, heat detection 
etc. The VP1006 must be connected to a computer (controller) and can communicate by a CAN, 
RS485 or RS232 protocol. The connected computer must give controlling commands to the VP1006 to 
operate inputs, outputs and identification.  
 
The VP1006 has the following main tasks: 

Identification of tags (ISO 134.2 kHz FDX/HDX) 

Controlling outputs - 6 outputs are available to activate e.g. lights, motors, valves, relays 

Reading inputs - 6 inputs available for e.g. sensors, switches 

 
Following antenna types can be used: 

V-sense antennas 

EWA transformer with stainless steel antenna strip 

HDPE antenna with HDPE antenna tuner 

 
The VP1006 must be installed in a housing suitable for farm conditions, for example in a V-box. 
 

 

 

 

Figure : V-box2 with a VP2002 power supply and a VP1006 reader 

 
Reference manuals : 
PS0000-200PM-00 Velos general description 
VP1002-200PM-00 ISO-Booster 
VP6001-200PM-00 V-sense 
 

FCC ID: CGDVELOS2 and IC: 1444A-VELOS2 

 

FCC_IC Statement 

This device complies with part 15 of the FCC Rules and 

with Industry Canada’s licence-exempt RSSs. 

Operation is subject to the following two conditions: 
(1) this device may not cause interference, and 
(2) this device must accept any interference, including interference that may cause undesired operation of the device. 

Warning (15.21)

  

Changes or modifications not expressly approved by the party responsible for compliance 

could void the user’s authority to 

operate the equipment. 
 
Cet appareil se conforme aux normes RSS exemptés de license du Industry Canada. L'opération est soumis aux deux 
conditions suivantes: 
(1) cet appareil ne doit causer aucune interférence, et  
(2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas voulu de 
cet appareil. 
 
Les changements ou modifications n’ayant pas été expressément approuvés par la partie responsable de la conformité peuvent 
faire perdre à l’utilisateur l’autorisation de faire fonctionner le matériel.

  

Содержание VP1006

Страница 1: ...Service manual For installation operation and service OEM ISO Reader VP1006 06 2017 Manual version 2 6...

Страница 2: ...I Neutrodynisation unit between two antennas Manual version 2 4 10 2013 Appendix C Display menu option ISO protocol added Manual version 2 5 06 2015 Appendix A Updated product specifications Manual v...

Страница 3: ...7 6 Advanced 8 6 1 Testing inputs and outputs 8 6 2 Advanced antenna adjustment 9 6 3 Identification test options 10 7 Trouble shooting 11 8 Maintenance cleaning and disposal 11 Appendix A Specificat...

Страница 4: ...VP1006 200PM 00 OEM ISO Reader Manual version 2 6...

Страница 5: ...installed in a housing suitable for farm conditions for example in a V box Figure V box2 with a VP2002 power supply and a VP1006 reader Reference manuals PS0000 200PM 00 Velos general description VP1...

Страница 6: ...hese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequent energy and if not inst...

Страница 7: ...reading tags normally on Inputs read continuously with status change sent to the controller Outputs switched on or off by commands from the controller LEDs switched on or off by the VP1006 according...

Страница 8: ...rmal output max 3A M Minus for motor output or normal output I Input of motor or normal input Minus for motor input or normal input I O 5 6 O Output max 250mA Minus for output O and minus input I I In...

Страница 9: ...r more details about the LED indicators see Appendix D If LED s are green continue with address settings 5 2 Communication bus termination jumper Termination is only used in case of RS485 communicatio...

Страница 10: ...ll now be 12 blinking on the display now If the address is accepted by the process unit the display goes blank How to check the address 1 Short press the button Ad will appear 2 Now hold the button un...

Страница 11: ...06 9 1 11 1 13 1 15 1 Use connection 9 1 to start Tuning Use a plastic screw driver to tune Tune the coil inside the EWA until the green LED of the antenna tuning is on When green the antenna tuning i...

Страница 12: ...pears 2 Now hold the button until the display starts blinking dE will appear 3 Short press on the button 2 times o1 will appear 4 Now hold the button until the display starts blinking Output 1 will be...

Страница 13: ...ion press the button until the display goes blank press about 4 seconds Antenna squelch Antenna squelch is a possibility to set a threshold for the ID level of a tag It means the antenna power is stil...

Страница 14: ...d to the same sync cable Antenna tuning visible by a light With HF menu option Adjust Antenna AA output 6 is also switched on By connecting a light to output 6 the status during tuning can be monitore...

Страница 15: ...hut off due to overload 16 Software switched off due to max current and time 17 CAN bus over voltage 18 Voltage to next module switched off Identification performance and disturbance Identification pe...

Страница 16: ...short circuiting protected Motor safe guard after 25 sec Antennas 800 H Different types possible Detection distance Varies per antenna Synchronisation Synchronisation according to ISO 11785 Environmen...

Страница 17: ...VP1006 200PM 00 OEM ISO Reader Manual version 2 6 Page 13...

Страница 18: ...tion to the VPU the address is shown It is also possible some program states of a behavior component are shown during operation Activate the menu short press on the button the display menu is shown Sc...

Страница 19: ...LEAR ERROR Shows error code and error clearing after showing TEST ALL OUTPUTS All outputs are switched on one by one Test results are shown on the display TEST MOTOR OUTPUT o1 o4 TEST OUTPUT L1 L6 TES...

Страница 20: ...p extended protocol 2400 Baud 21 RS485 Bias on no of breaks 0 41 Nedap extended protocol 9600 Baud 22 RS485 Bias off no of breaks 2 42 Nedap extended protocol 19200 Baud 23 RS485 Bias on no of breaks...

Страница 21: ...and Vout swapped Red Error plus and minus swapped V out Green on Output power off No power Orange blinking Low power Red blinking Error plus and minus swapped COM Green on V pack is last one on the b...

Страница 22: ...shield red black shield red black orange orange white shield To RS485 interface of computer Last VP1006 Jumper up RS485 cable specifications PC to first VP1006 Wires min 0 34 mm 2 twisted pair shielde...

Страница 23: ...range white red black blue blue white shield red black orange orange white blue blue white shield B A To RS485 interface of computer blue blue white shield B A shield blue blue white shield B A RS485...

Страница 24: ...version 2 6 Page 20 Appendix G RS232 connections RS 232 port of computer TxD pin3 RxD pin2 GND pin5 RS232 cable specifications Shielded cable Wires min 0 34 mm2 Max length between PC and VP1006 15 met...

Страница 25: ...white blue blue white shield shield red black orange orange white blue blue white shield red black orange orange white blue blue white shield red black orange orange white blue blue white red black or...

Страница 26: ...t Coax cable specification RG58 Cable between the readers to connect SYNC OUT and SYNC IN shield core shield core READER A READER B Display value 0 99 Turn to max display value Neutrodynisation adjust...

Страница 27: ......

Отзывы: