background image

TRANSIT Ultimate | installation guide 

 

12/40 

 

2.5

 

Installing a communication board 

The TRANSIT Ultimate features an on-board USB port and a Wiegand / Magstripe / Barcode interface. See chapter 4.3 
for more details. 
 
Other communication interfaces can modularly be installed in the reader by means of a communication interface board. 
There are various communication interface boards available for the TRANSIT Ultimate. See appendix C for available 
boards and their part numbers. 
 
Make sure to follow all safety precautions outlined in chapter 2.1 when installing or replacing a communication board. 
 

Communication board installation procedure: 

 
1.

 

Open the TRANSIT Ultimate. You can put the cover strut into place to keep the cover open. 

2.

 

Disconnect the power supply. 

3.

 

Place the communication interface board on the 14-pin header K5 as indicated in the picture below. 

4.

 

Make sure that the 4 plastic PCB supports are properly positioned and fixed into the communication board. 

5.

 

Read the communication board’s installation guide for additional notes like address setting, jumper settings and 
wiring details. 

6.

 

Test if the communication works correctly. 

7.

 

Close the cover of the TRANSIT Ultimate. 

 
 

PCC485/OSDP 

The PCC485/OSDP converter board is not installed as described above. 
Please refer to chapter 3 for more details. 
 

 

 

Содержание Transit Ultimate

Страница 1: ...www nedapidentification com installation guide 2020 05 13 v5 08 Doc no 5481104 TRANSIT Ultimate...

Страница 2: ...ling the security key pack 11 2 5 Installing a communication board 12 3 OSDP Interface Board 13 3 1 TRANSIT wiring 13 3 2 RS485 OSDP wiring 14 3 3 TRANSIT configuration 15 4 Connections 16 4 1 Overvie...

Страница 3: ...ation select 30 6 4 Frequency select 31 6 4 1 Frequency select display buttons 31 6 4 2 Frequency select dip switches 31 6 5 Read range control 32 6 6 Microwave time sharing 33 7 LED indications 34 7...

Страница 4: ...vicinity of each other without interference Read range adjustment The reader efficiently resolves typical multi lane entry and exit reader challenges The read range of the TRANSIT Ultimate can be adju...

Страница 5: ...crypted tag authentication is performed when both antennas 433MHz and 2 45GHz receive the same id number This ensures that the tag to be authenticated is located in the well defined directional beam i...

Страница 6: ...icated by NEDAP 2 2 Installation guidelines The TRANSIT Ultimate can be installed in any position The normally expected read range is up to 10 meters The hinges should be on top of the reader Landscap...

Страница 7: ...nting brackets and the locations of the mounting positions 2 3 1 TRANSIT Ultimate dimensions The picture below shows the dimensions of the TRANSIT Ultimate All dimensions are in mm Figure 2 Dimensions...

Страница 8: ...h the TRANSIT Ultimate reader When the Wall Mounting Set is assembled mount it to the wall or to the Pole Mounting Set based on the dimensions in Figure 3 The TRANSIT Ultimate can be aimed with the Wa...

Страница 9: ...with maximum diameter of 190 mm and square poles with maximum diameter of 150 mm using the Pole Mounting Kit The Pole Mounting Kit has to be ordered separately art no 5626595 The Wall Mounting Set wil...

Страница 10: ...3 4 Weather protection hood The Weather Protection hood is recommended when the reader is installed in direct sunlight The Weather Protection Hood has to be ordered separately art no 9218327 Figure 5...

Страница 11: ...ck installation procedure Insert the Security Key Pack SAM into the TAB board 1 Align the notch as indicated in Figure 6 and keep the metal contacts backwards 2 Push the SAM into the slot until it cli...

Страница 12: ...g or replacing a communication board Communication board installation procedure 1 Open the TRANSIT Ultimate You can put the cover strut into place to keep the cover open 2 Disconnect the power supply...

Страница 13: ...s Make sure to follow all safety precautions outlined in chapter 2 1 OSDP Interface Board installation procedure 1 Connect the OSDP Interface Board PCC485 with TRANSIT as described in chapter 3 1 2 Co...

Страница 14: ...8 RS485 OSDP point to point wiring For multi drop communication disable the termination resistor on the PCC485 on all devices except the last device The termination resistor should be enabled on the...

Страница 15: ...ettings P81 v3 35 P82 v3 08 P83 v3 04 P84 v3 06 P85 v3 01 Newer versions are also supported as they will be backwards compatible Configuration settings The relay activation and LED control must both b...

Страница 16: ...connections overview Power supply See chapter 4 2 Read disable input See chapter 4 4 2 General purpose inputs See chapter 4 4 4 Proximity antenna See chapter 4 5 1 Relay output See chapter 4 4 1 Tamp...

Страница 17: ...and VAC N The earth wire should be connected to the dedicated safety ground connection Input voltage 100 240 VAC Frequency 60 50 Hz Figure 12 AC mains connections 4 2 2 DC supply input Connect the DC...

Страница 18: ...4 2 3 DC output The DC output can be used to supply power to an additional device installed inside or near the TRANSIT Ultimate Figure 14 DC output connections DC output ratings Output voltage 23 4 VD...

Страница 19: ...t the USB cable Make sure the HID interface board is installed correctly Restart the TRANSIT Ultimate or press reset button Figure 15 USB connection USB driver installation Make sure your computer is...

Страница 20: ...rotocol output depends upon the reader firmware Please refer to the firmware manual for more details Connections Wiegand Magstripe Barcode O 1 Card Loaded O 2 Data 0 green Clock O 3 Data 1 white Data...

Страница 21: ...le when the RS422 485 interface board has been installed SW1 selects RS422 or RS485 SW2 enables the termination resistor It is recommended to keep this switch in ON position Figure 17 RS422 485 switch...

Страница 22: ...mate mode is enabled See chapter 6 1 for more details By default the front cover LED lights up simultaneously with the relay output This might be changed by enabling manual relay led activation mode S...

Страница 23: ...th a sensor e g inductive loop that detects the presence of a person or vehicle Use a potential free contact relay to connect the internal 5V to the RDIS input Leave open or unconnected when reading s...

Страница 24: ...system The contacts are normally closed when the cover is in place Tamper switches of multiple TRANSIT Ultimate readers may be connected in series Connections TAMPER Tamper switch contacts normally c...

Страница 25: ...unconnected when not used or inactive Depending upon the used firmware version these inputs optionally can be used to activate the relay or control the front cover 3 color LED See for more details th...

Страница 26: ...or a NEDAP reader with antenna modulation output e g NVITE or uPASS Access Connections HF Antenna HF Antenna cable shield UL Green LED output max 18mA GND Ground for LEDs NA Red LED output max 18 mA...

Страница 27: ...enna modulation interface can also be used to connect the TRANSIT Ultimate to NEDAP AEOS access control hardware such as the AP1001 Connections MHF Antenna modulation output connect to PCC485 HF or AP...

Страница 28: ...can be changed or updated using the TRANSIT Firmware Upgrade software tool Firmware update procedure Start TRANSIT Firmware Update PICLOAD software Select communication port e g COM1 Select the firmwa...

Страница 29: ...Ultimate mode The TRANSIT Ultimate can operate in the ULTIMATE mode or in the NORMAL mode In the ULTIMATE mode the TRANSIT will perform a secure mutual authentication on the tags This only works in c...

Страница 30: ...al communication select By default the USB or communication interface board connections will allow communication with the TRANSIT processor PIC The communication protocol is determined by the TRANSIT...

Страница 31: ...splay push buttons see chapter 6 4 1 or using dip switches see chapter 6 4 2 The TAB board operates at 433 MHz It uses 2 fixed frequency channels This cannot be changed 6 4 1 Frequency select display...

Страница 32: ...nge is done by enabling the squelch and setting the squelch level with its potentiometer For maximum read range disable the squelch function completely with the enable disable squelch switch LED SQ AC...

Страница 33: ...use the same frequency undisturbed The reader will be on for 300 milliseconds which is long enough for a reliable identification of a tag The off time is between 0 5 and 5 seconds This is configurabl...

Страница 34: ...ed INPUT 3 Input 3 status On when contact is closed Tx Transmit serial data USB I F board See chapter 4 3 Rx Receive serial data USB I F board STS LED TRANSIT firmware status LED PIC Slow blinking Hea...

Страница 35: ...ink 1 Programmer firmware 0 1s on 0 9s off Special blink 9 TAB stopped Hardware fault 0 9s on 0 1s off ERR Error LED SAM error not present not locked not supported etc TAB error authentication failed...

Страница 36: ...Air interface 433 MHz Encryption based upon diversified AES128 keys 300 kbps GFSK 75kHz dedicated antenna Duty cycle 1 LBT not applicable Relay output 1 relay output NO common NC 24 VDC 2A Inputs 3 dr...

Страница 37: ...68 ON OFF OFF OFF ON 5F 2 4474 OFF OFF OFF OFF ON CH8 60 2 4480 ON ON ON ON OFF 61 2 4486 OFF ON ON ON OFF 62 2 4492 ON OFF ON ON OFF 63 2 4498 OFF OFF ON ON OFF 64 2 4504 ON ON OFF ON OFF 65 2 4510 O...

Страница 38: ...ey Pack SAM 5626595 Pole Mounting Kit 9218327 Weather Protection Hood 9229078 OSDP Installation Board includes PCC485 7819102 HID interface board HIB 7817940 TCP IP interface board 7817347 RS422 485 i...

Страница 39: ...ly with FCC RF exposure requirements for mobile transmitting devices this transmitter should only be used or installed at locations where there is at least 20cm separation distance between the antenna...

Страница 40: ...20 04 10 HR added OSDP Kit 5 05 2019 05 08 HR updated antenna modulation 5 04 2018 07 12 HR removed profibus obsolete 5 03 2018 05 23 HR added remarks when using USB interface 5 02 2018 05 02 GSA Adde...