Nedap Smart Deactivator Скачать руководство пользователя страница 5

5

System overview

SMART DEAC

Nedap Part.no. 9937676

Antenna

Model: SDA-265x265

Nedap Part.no.: 9564101

or

Model: DAPL-275x275

Nedap Part.no.: 9911537

Power Adapter

Nedap Part.no.: 9651802

LED

Nedap Part.no.: 9563652

Input

Output

RS485 communication

1

7

6

5

2

4

3

Figure 1 Functional system overview

The SMART DEAC system (Figure 1) consists of the following components:

1. 

AC/DC Power adapter Wall Mount 100 – 240 VAC / 12 VDC Nedap Part.no.: (9551802)

2. Smart Deactivator electronics  (9937676)
3. Antenna including cable - Model: SDA-265x265 (9564101) or Model: DAPL-275x275 (9911537)
4. 

RS485 connection to communicate with the SMART DEAC

5. 

Input for functionality to be defined

6. 

Output for functionality to be defined

7. LED for visual indication (9563652)

The SMART DEAC system is plug & play. You only have to follow the next steps: 

• 

Install the Smart Deactivator system according the instructions;

• 

Power up the Smart Deactivator system;

• 

Check the functionality; by deactivating a RF label above the antenna and check it for a audio signal.

• 

Call Nedap EAS Support for quick hands-on problem solution in case of unforeseen trouble  
(see Technical Support on page 2)

Содержание Smart Deactivator

Страница 1: ...Smart Deactivator Manual UL manual smart deactivator according to ul regulations SMART DEAC Mounting SMART DEAC Wiring Appendix 1 Quick Reference...

Страница 2: ...ctrical and electronic equipment falling under Annex IA of Directive 2002 96 EC provided the equipment concerned is not part of another type of equipment that does not fall within the scope of this Di...

Страница 3: ...3 Table of content 1 Introduction 4 2 System overview 5 3 Installation instructions 6 4 Regulatory declaration 7 5 Specifications SMART DEAC 8 6 Appendix 1 9...

Страница 4: ...ivator advantages are 1 Constant optimal deactivation distance independent of the tag frequency between 7 2 8 8 MHz 2 Deactivation behavior programmable with switches 3 Detect only Mode 4 Deactivation...

Страница 5: ...cs 9937676 3 Antenna including cable Model SDA 265x265 9564101 or Model DAPL 275x275 9911537 4 RS485 connection to communicate with the SMART DEAC 5 Input for functionality to be defined 6 Output for...

Страница 6: ...utput voltages will be 12Vdc or less The inputs may only be connected to class2 powered system The SMARTDEAC must be mounted on a solid nonflammable surface using all mounting holes and proper mountin...

Страница 7: ...equipment has been tested and found to comply with the limits for a class B digital devices pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harm...

Страница 8: ...0 35 A 0 7 A 264 VAC 90 VAC Line Frequency 47 Hz 50 60 Hz 63 Hz Operation Voltage Power 3 W 230 VAC 50Hz Regulations Safety approvals of the Power Adapter cULus according to UL CSA 60950 1 CB accordi...

Страница 9: ...rt of this drawing may be reproduced or distributed in any form or by any means or stored in a data base or retrieval system without the prior written permission of NEDAP article no date rev dsgn page...

Страница 10: ...ng T9937 676 1x Smart Deactivator including power supply Smart Deactivator 1x Antenna connector set 05 Beeper sound volume 04 Connect to power 100 240V deactivation detection 06 Beeper sound Standard...

Страница 11: ...itivity Software 6 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Standard mode Line Termination RS485 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Detect only mode 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Output after...

Страница 12: ...parallelweg 2d nl 7141 dc groenlo the netherlands t f e i 31 0 544 471555 31 0 544 465814 info rs nedap com www nedap retail com 2014 v1...

Отзывы: