4.4.

 

Connections using RS485 

Convexs/Invexs  connected  to  Nedap  AEpacks  using  RS485:  For  those 
AEpacks not having RS485 on board use the additional AX1012 (RS485 
to RS232 converter) 
 
 
 
 
 
 
 
 
 
 
 
 
Remarks: 

1

 

On AP1003 the RS485 is available on Upper Row connector points 13 - 16, only from PMS D or higher 

2

 

For AP1003 with PMS below D use the additional AX1012 to convert RS232 from AP1003 to RS485 for 

Convexs 

3

 

Power for Convexs can be supplied by 

-

 

External Power Supply 

-

 

AEpack, check correct voltage and current at given AEpack output 

4

 

Beeper on Convexs can be optional controlled 

-

 

on AP6003 this can be done by pin 16 

-

 

on other AEpacks use Relais output 

5

 

LED control is supplied over the RS485 communication, so no additional wiring is needed 

6

 

Cable  shield  must  be  connected  to  Power  GND  of  Convexs  (A2)  and  GND  of  external  device  or  metal 

case of the external device (at housing of AP6003, AP4x03x, AEbox) 

7

 

If Convexs replaces e.g. DC130 antenna the existing cabling of the DC130 antenna (4 x 0,25qmm) can be 

reused  for  RS485  and  Power  only  if  cable  length  not  exeeds  50  meters  and  cable  shield  is  correct 
connected. 

8

 

PIN code for the Invexs reader is transmitted using the RS485 communication. 

 

4.5.

 

Connections using RF output 

 
 
 
 
 
 
 
 
 
 
 
Remarks: 

1

 

For  Nedap  reader  AEpacks  the  AX1014  must  be  applied  to 

each AEpack 

2

 

For the Accessor III / SimpleXS / AC3/2TR the AB350 must be applied 

3

 

Existing cabling can be re-used when the Nedap antenna is replaced by the Convexs 

4

 

Power is supplied to the Convexs by the RF signals on A1 and A2, no additional Power Supply is needed. 

5

 

Beeper can be controlled optional by making the correct configuration settings or hardware connection. 

6

 

Cable  shield  must  be  connected  to  Power  GND  of  Convexs  (A2)  and  GND  of  external  device  or  metal 

case of the external device (at housing of Accessor, AP4x01, AEbox) 

7

 

PIN code for Invexs readers is NOT possible 

8

 

Invexs  190  to  AX1014  or  AB350  needs  additional  connection  between  GND  (for  UL  and  NA)  and 

Antenna GND 

on

 the AX1014 / AB350 (Invexs 190 has no separate cable for this connection) 

AX1014 

AX1014 

AX1014 

AX1014 

AX1014 

Accessor III / 

SimpleXS 

AC3/2TR 

AB350 

Convexs / Invexs 

AP6003 

AP4x03x 

AP1003 

1)

 

AX1012  

2)

 

A1 

Power / XSMOD 

Lower 1 

3)

 

     1  

3)

 

Upper 

    1 

3)

 

Upper 

    1 

3)

 

A2 

POWER GND/shield 

14 

14 

Lower 

Lower 

A3 

A (-) 

Upper 

13 

AX1012 

Rx+ 

A4 

B (+) 

10 

10 

Upper 

16 

AX1012 

Rx- 

A5 

D0 

 

-- 

-- 

 

-- 

 

A6 

D1 

 

-- 

-- 

 

-- 

 

A7 

BEEP 

16 

4)

 

-- 

-- 

 

-- 

 

A8 

UL* 

 

-- 

-- 

 

-- 

 

A9 

GND 

 

-- 

-- 

 

-- 

 

A10 

10 

NA* 

 

-- 

-- 

 

-- 

 

 

Convexs / Invexs 

AX1014 

AB350 

A1 

Power / XSMOD 

11 – ANT 

ANT 

A2 

POWER GND/shield 

12 – GND 

GND 

A3 

A (-) 

 

 

A4 

B (+) 

 

 

A5 

D0 

 

-- 

A6 

D1 

 

-- 

A7 

BEEP 

relay 

relay-- 

A8 

UL* 

13 – UL* 

UL* 

A9 

GND 

8

 

14 – GND 

GND 

A10 

10 

NA* 

15 – NA* 

NA* 

 

1 2 3

4 5 6

7 8 9

C 0 E

1 2 3

4 5 6

7 8 9

C 0 E

1 2 3

4 5 6

7 8 9

C 0 E

Содержание Invexs M190

Страница 1: ...ability for any consequence of its use specifica tions and availability of goods mentioned in it are subject to change without notice it is not to be reproduced in any way in whole or in part without the written consent of the publisher Nedap N V IDEAS P O Box 103 NL 7140 AC GROENLO The Netherlands Page 1 of 21 Nedap Readers Convexs Invexs Installation Guide and User Manual 1 2 3 4 5 6 7 8 9 C 0 E...

Страница 2: ...__________________________ 11 3 4 Serial RS485 RS485 Ascii _______________________________________________________ 12 3 4 1 Default settings __________________________________________________________ 12 3 4 2 Data format _____________________________________________________________ 12 3 5 USB Desktop reader _____________________________________________________________ 12 3 5 1 Default settings ___...

Страница 3: ...e Convexs Invexs _________________________________________________ 18 9 Default settings of the Convexs Invexs ___________________________________________________ 18 10 Available reader firmware _____________________________________________________________ 19 10 1 AEOS versions _________________________________________________________________ 19 11 Known problems __________________________________...

Страница 4: ...390 9895990 Mifare Nedap Convexs MND80xx 9896210 9896040 9896350 9896180 Mifare Nedap DESFire Gray Charcoal Flush Gray Flush Charcoal Gray Light Charcoal Dark For both Surface mounting and flush mounting rugged Protectors are available making the Convexs more vandal resistant 1 3 Availability Invexs 170 readers The Invexs can read Mifare DESFire and Nedap cards and is equipped with keypad and or a...

Страница 5: ...ed by the communication over RS485 No separate cables for the LED s are used Beeper also can be controlled by hardware or configuration Power must be supplied additionally to the Convexs Invexs Not all Nedap AEpacks have RS485 on board Check the used AEpacks Use the AX1012 to convert RS232 to RS485 RF output To be connected to o AEOS Nedap reader AEpacks e g AP1001 AP4001 using AX1014 All data Ned...

Страница 6: ...D s are controlled by the two separate connections between Convexs Invexs and the third party system Beeper controlled by hardware or configuration Power must be supplied additionally to the Convexs Invexs Serial RS485 RS485 Ascii To be used for connection to third party systems using a serial connection Requires special configuration in Convexs Invexs NR9002 cfg LED s can be controlled by the two...

Страница 7: ...ad Mifare Mifare Ultralight and DESFire including EV1 Card Serial Number CSN 7 bytes or 4 bytes Data direct from one of the sectors files Data from one of the sectors using MAD Mifare Application Directory All necessary settings MAD or sector number used security keys location of data interpretation of the data etc have to be made using AEreco If desired this can be done by the customer itself so ...

Страница 8: ... as RS485NR 3 2 RF output Using Convexs converters AX1014 AB350 enables re use of existing cabling both for antenna and LED s The RF output is to be used if the Convexs Invexs have to be connected to the former Nedap XS readers Accessor SimpleXS or the Nedap AEpacks Depending of the possibilities and firmware of the used Nedap readers following options are available Cabling distance Max 50 meters ...

Страница 9: ...for Nedap XS readers AB350 on Accessor SimpleXS to be connected to the WinXS system using e g LanBoXS or InterVisor or directly to the WinXS PC This option can be used if e g the existing Nedap RF antenna on the XS reader is replaced with the Convexs Invexs thus enabling that both Nedap and Mifare cards or Mifare cards replacing Nedap cards can be read For each XS reader one AB350 Convexs adapter ...

Страница 10: ...255 Label number 16 bits range 1 65535 Parity 2 bits 3 3 3 1 Wiegand 26 data definition The Wiegand 26 bit format consists of a parity bit followed by eight facility code bits followed by 16 label number code bits and a final parity bit The first parity bit shall create even parity when combined with the next twelve bits The last parity bit shall create odd parity when combined with the remaining ...

Страница 11: ...n hex first bit first 3 3 6 Wiegand 37 Format Label number 35 bits range 1 34359738368 3 3 6 1 Wiegand 37 data definition The Wiegand 37 bit format consists of one number no facility code There are 2 parity bits The data is sent in bits unsigned binary coded The complete message consists of the following Bit position 1 23456789 0123456789 0123456789 0123456 7 Bit contents P NNNNNNNN NNNNNNNNNN NNN...

Страница 12: ...f type of identifier and configuration file CR OD hex LF OA hex Remark If Mifare block data is used the block decoder must be used to interpret the data Using AEreco from version 2 00 user specific header trailer can be detemined Check AEreco user manual 3 5 USB Desktop reader Uses USB to communicate to other systems Inside the USB Desktop reader a Convexs reader is used with special configuration...

Страница 13: ... GND for UL and NA and Antenna GND on the AX1014 AB350 Invexs 190 has no separate cable for this connection Convexs Function A1 Power XSMOD Power in 10 30VDC XS modulator 120kHz A2 POWER GND shield Power Ground A3 A RS485 A4 B RS485 A5 D0 Wiegand Data 0 A6 D1 Wiegand Data 1 A7 BEEP Beep input A8 UL UL led input A9 GND Led Beep Common Ground A10 NA NA led input Convexs Rear view Invexs Function 1 P...

Страница 14: ...using RF output Remarks 1 For Nedap reader AEpacks the AX1014 must be applied to each AEpack 2 For the Accessor III SimpleXS AC3 2TR the AB350 must be applied 3 Existing cabling can be re used when the Nedap antenna is replaced by the Convexs 4 Power is supplied to the Convexs by the RF signals on A1 and A2 no additional Power Supply is needed 5 Beeper can be controlled optional by making the corr...

Страница 15: ...the third party system and optional from the used configuration 2Cable shield must be connected to Power GND of Convexs A2 and GND of external device or metal case of the external device 3PIN code is possible over Wiegand 1 2 3 4 5 6 7 8 9 C 0 Convexs Invexs Third party system A1 1 w1 Power XSMOD Power A2 2 w2 POWER GND shield Power GND A3 3 w3 A A4 4 w4 B A5 5 w5 D0 Data 0 A6 6 w6 D1 Data 1 A7 7 ...

Страница 16: ...volume of the beeper can also be controlled by AEreco valid for both hardware and software setting The beeper is also used for indicating the status of loading the configuration at the Convexs Invexs 5 3 Status LED s The blue LED at the front side is used to indicate if a configuration is loaded at the Convexs Invexs The blue status LED at the backside is used to indicate the status of the Convexs...

Страница 17: ...lable enabled If DESFire is enabled and this reader is suitable using DESFire can be checked with AEmon at the View Hardware only with the rs485NR protocols Select the Nedap reader and check with options are available OptionsAvailable and which are enabled OptionsEnabled A configuration of a Convexs Invexs can not be read back from the Convexs Invexs so when making changes to a configuration you a...

Страница 18: ...figuration cards with the same Reader read key can change the configuration of a Convexs Invexs This key is independent of the Mifare keys 8 Updating firmware of the Convexs Invexs If new firmware must be loading into the Convexs Invexs reader this can be done by Using AEmon the Convexs Invexs is connected to the AEOS reader AEpack APx003rs485NR or APx003rs485NR2 the Convexs Invexs must have the R...

Страница 19: ...rable to use always this protocol o rs485NR Convexs Invexs is not visible in AEmon only AEpack to it is connected is shown First implementation of rs485NR protocol Not available for AP4x03 The AP4x03 RS485NR is only available for the X version up from version v3 1x and must have at least Kernel version 3 10 Tamper switch and PIN not available at the AP4x03X only at the AP1003 with RS485 AP4003X rs...

Страница 20: ...least kernel 3 10 and corresponding firmware For the AP4x03 with kernel version 2 connecting the Convexs Invexs with RS485 using the rs485NR firmware is NOT possible This is solved with the rs485NR2 firmware This firmware is suitable for both AP4x03 and APx03X and AP1003 AP6003 Check always the version of firmware for the AEpu see Remarks at chapter 10 11 4 Convexs Invexs to AP4003 using RS485 Tam...

Страница 21: ...uiry information removed to separate doc 25 01 2010 5 REW Blue led only with RS485 communication available added 23 11 2009 5 REW MND added check DESFire in AEmon added 08 09 2009 4 REW Known problems extended with Nedap readers instead of AP4001 AM badge 16 07 2009 4 REW rs485NR2 added available also for AP4x03 LED Beeper control changed 28 05 2009 3 REW Invexs added 12 03 2009 REW Known problem ...

Отзывы: