NED
U M-0099-03
RMSL6K17GE
53
4.2.8.3
Setting Memory Saving
(Saving the camera setting data into the flash memory)
The current camera setting data is saved in the flash memory.
・
Register name
User Set Save
・
VAL
Execute()
(Example)
User Set Selector : User Set 1
(
Selecting User setting
)
User Set Save : Execute()
(
Saving User setting data
)
4.2.8.4
Resetting Factory camera setting
Follow the steps below to set the camera setting at the time of factory shipping.
①
Select “Default” on “User Set Selector”
User Set Selector: Default
②
Set the “Execute()” on “User Set Load “
User Set Load : Execute()
The camera setting data at the time of factory shipping is read from the flash
momory and is used to operate the camera.
* The camera setting data at factory shipping can be used to operate the camera
by the step
②
until the power for camera is off.
After the power is off and then on, the previous camera setting data is used
to operate the camera unless the step
③