NED
UME-0069-03
NUCLi7370AT6
31
>OK
>tap1
4.2.5 Setting Output Signals (Setting Data Format)
Sets the data format of output signals.
Format 2
CMD VAL CR
CMD
v
VAL
0,1
<Example>
v0CR
(
8bit output
)
>OK
>v0
4.2.6 Setting Output Data Rate
Sets the data rate format of output signals.
Format 2
CMD VAL CR
CMD
clkcl
VAL
70,85
<Example>
clkcl
(
70MHz output
)
>OK
>clkcl70
4.2.7 Readout the Operation Status
Reads out the current camera settings.
Format 1
CMD CR
CMD
sta
<Example>
sta
>OK
>Type=NUCLi7370AT6
>Ver.=0.95
>r0
>g0
>b0
>grfo92
>grfe93
>grro91