The Nectre MK3 comes with 11 full size bricks (230(h)
x 115(w) x 38(d)mm).
Raise the brick retainer (supplied inside the firebox) and
start standing the bricks up against the rear and sides of
the firebox as shown in the diagram below.
Once bricks are in, fit the retainer over the top to hold
them in place.
The Nectre MK3 is supplied with two baffle plates:-
1)
Upper baffle plate
–
400(w) x 160(d) x 5(h) mm.
•
Fit the upper baffle plate first.
•
With the plate in a horizontal position, slide it up and
over the shorter of the two sets of support hooks
welded to the top of the firebox.
•
Slide the plate back so that it rests on the upper
support rod on rear wall of the firebox.
•
The upper baffle plate should be in a horizontal
orientation.
2)
Lower baffle plate
–
500(w) x 300(d) x 12(h) mm
•
Slide the lower baffle plate up and over the lower set
of support hooks welded to the top of the firebox.
•
Slide the plate back so that it rests on the lower
support rod on the rear wall of the firebox.
•
Unlike the upper baffle plate, the lower baffle plate
rests on a slight angle sloping down and back to the
rear of the firebox.
The ash plate acts to protect the front of the firebox below
the door opening from the hot coal bed and fire.
When positioning the ash plate, ensure that the front top
edge is flush against the inside edge of the firebox beneath
the door opening.
5. INSTALLING FIRE BRICKS
6. INSTALLING BAFFLE PLATES
7. INSTALLING ASH PLATE
Upper baffle plate
support lug
Lower baffle plate
Upper baffle plate
Lower baffle plate
support lug
Ash plate