9
NECTRE 800 WALL HEATER – SUGGESTED FRAMING
The diagram on the next page shows a suggested wall enclosure for the Nectre
800 Wall Heater. Assuming a ceiling height of 2400mm, a timber frame has been
constructed using 90x35mm timber, 2400mm high, 1200mm wide, and 525mm
deep. With timber supports for the steel cross bearers at 390mm high, the base
of the heater will be 590mm above the floor.
A non-combustible material such as
Versalux
fibro cement sheeting is used on
the front wall, and standard gyprock or equivalent can be used on the side walls.
Vents have been positioned top and bottom on both side walls.
This construction complies with the minimum clearance requirements.
The height of the heater above the floor and/or the width of the enclosure may be
varied as long as it meets the clearances defined above.