manualshive.com logo in svg
background image

PREMIUM PORTRAIT WOOD HEATER

OPERATING INSTRUCTIONS

Содержание Form 2 Series

Страница 1: ...PREMIUM PORTRAIT WOOD HEATER OPERATING INSTRUCTIONS...

Страница 2: ...Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA VERSION 1 0 NECTRE FORM 2 NF2 22...

Страница 3: ...4 6 Burning Tips 4 6 1 Fuel Quality 4 6 2 Flue Draught 4 7 Ash Removal 5 8 Flue Chimney Fire 5 9 Cleaning Paintwork and Glass 5 10 Cleaning the Flue 5 11 Troubleshooting Tips 6 11 1 Glass in Door Bla...

Страница 4: ...ny way without the written approval of the manufacturer Extraction fans or rangehoods placed in the same room or space can cause appliance to emit smoke into the room unless outside air kit is install...

Страница 5: ...ldup of creosote soot in the flue which will then require regular cleaning and may result in a flue fire Do not burn painted impregnated treated wood manufactured board products or pallet wood 4 LIGHT...

Страница 6: ...resh wood to catch 6 After 10 or more minutes the air control can be adjusted to the desired heat output setting 6 BURNING TIPS 6 1 FUEL QUALITY Use wood with a moisture content of less than 20 Logs s...

Страница 7: ...e cleaner or scourer pads 10 CLEANING THE FLUE Check inside of flue prior to each season for any build up of creosote wood tar To do this 1 First remove the baffle refer to 2 Replacement of Baffle und...

Страница 8: ...flue draught Contact the installer should this happen 11 2 TROUBLE STARTING THE FIRE If all ash has been removed from the firebox it can upset the supply of air to the base of the fire When cleaning...

Страница 9: ...icks with two angled edges one on either corner of the firebox Ensure angled cut meets up neatly with side bricks 3 One large brick at the rear Once bricks are in fit the retainer over the top to hold...

Страница 10: ...door from the heater and lay it horizontally on a work bench 1 Six small stainless steel tabs hold the glass in place Remove the screws from the stainless steel strips with a 4mm hex key 2 Take out t...

Страница 11: ...h that fastens at two points highlghted in the diagram below These latch points can be adjusted forwards and backwards as needed To adjust the door latch 1 Using 8mm spanner hold the M5 hex nut tight...

Страница 12: ...3 x 285 x 25mm tapered vermiculite N111 041 Door seal 1810mm x 14mm round fibreglass rope N111 096 Glass replacement kit 1 x glass 5mm pyro ceramic curved 1 x glass seal 1630 x 8 x 3mm flat adhesive b...

Страница 13: ...rvice to maintain them Under the terms of this warranty Glen Dimplex Australia Pty Ltd assumes no responsibility for the labour costs involved in removing or replacing the stove Nor shall Glen Dimplex...

Страница 14: ...12...

Страница 15: ...13...

Страница 16: ...ustralia Pty Ltd 8 Lakeview Drive Scoresby Victoria 3179 Australia T 1300 556 816 F 1800 058 900 General and Sales Enquiries flame glendimplex com au Technical Service service glendimplex com au www g...

Отзывы: