Miscellaneous Machine info
Installation date
Machine code
Code operator
Initialising
EVADTS
Pass code
Security code
Connection
GSM
Pin code
setting the code
Pre-alarms
setting the thresholds
resetting the counters
No. in bank
number of a machine
in the bank
FAILURES
READING PRESENT FAILURES
When the “Failure” function is displayed, press the confirm
button “ ” to display the present failures.
If no failures are currently present, after pressing the
confirm button “ ” the message “End failures” will be
displayed.
The possible failures are indicated in the following cases:
No water
If the air-break micro-switch is closed for more than one
minute, the water inlet solenoid valve will remain energized
until the water flow is restored.
Boiler
The machine will lock if after 10 minutes of heating from the
machine start, or from the last selection, the boiler fails to
reach the operating temperature.
Mobile spouts
If the spouts do not reach the dispensing position, the
machine is disabled.
No cups
When the empty cup stack micro-switch opens, the stack
shift motor is activated. If after one full turn of the cup
dispenser the micro-switch is not closed the machine
locks.
Espresso unit
Due to mechanical blocking of the unit. The machine is not
locked, but all tea-based selections are disabled.
No coffee
If after a period of 15 seconds of grinding coffee a dose is
not obtained, all coffee-based selections are disabled.
Coffee release
If after releasing the ground coffee dose the micro-switch
of the coffee doser unit indicates the presence of coffee in
the dosing chamber, all coffee-based selections are disa-
bled.
Volumetric counter
Failed computation of the volumetric counter within a
maximum given time.
Waste container full
This occurs after the liquid waste container float is trig-
gered.
Air-break
The machine is locked if after 7 selections the micro-switch
has never signalled the lack of water.
Coin mechanism
The machine is locked if it receives a pulse longer than 2
seconds on a validator line or the communication with the
serial coin mechanism does not take place for more than
30 seconds (Executive protocol) or 75 seconds (BDV
protocol).
RAM Data
One or more areas of the RAM contain wrong data which
was corrected with the default values.
The machine will continue to function, but it would be
advisable to initialise as soon as possible.
Machine control board
Failed dialogue between C.P.U. board and machine con-
trol board.
RESET
By confirming this function all current failures will be reset.
Содержание KIKKO ES6
Страница 2: ......
Страница 4: ......
Страница 65: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 66: ...Sx372 01...
Страница 67: ...Kikko instant...
Страница 68: ...Sx374 02...
Страница 69: ...Kikko espresso...
Страница 70: ...Sx373 01...
Страница 71: ...Kikko...
Страница 72: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 73: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 74: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 76: ......