3.1.3
Switch Settings
The following Table 5-1 CPUB( )-U13 ETU Default Switch
Settings indicates the default switch settings.
Table 5-1 CPUB( )-U13 ETU Default Switch Settings
SW1-1
SW1-2
Description
Off
Off
Normal Operation
On
Off
Flash ROM load from COM1 port
Off
On
Factory Test
On
On
Flash ROM load from EPROM
SW1-3
Description
Off
Not Used
SW2
Description
Momentary Switch
System Reset
SW3-1
Description
On
System boot by EPROM
Off
System boot by Flash ROM
SW3-2
Description
Off
Not Used
Pressing SW2 interrupts all service and causes
a second initialization. This switch should not
be used in an operating system unless
absolutely necessary.
!