![NEC XEN IPK DIGITAL TELEPHONE Скачать руководство пользователя страница 208](http://html.mh-extra.com/html/nec/xen-ipk-digital-telephone/xen-ipk-digital-telephone_programming-manual_248366208.webp)
188 – Chapter 1
DRAFT 3
Automated Attendant Extension Number Assignment, 1-4-21
December 2004
NEC Business Solutions Ltd
Doc.
No.: 8194 -
Release 2.0
Dece
mber 2004
1-4-21
System Mode
1
Submode
4
Data No.
21
PC Programming
+ AU
Automated Attendant
Extension Number
Assignment
General Description
Use this Memory Block to assign the extension number of each AA message.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 +
BA
to access the Memory Block.
3
Use the dial pad to enter data.
Note:
Use the following to enter data:
A
~
H
to enter Automated Attendant message number
2-Digit Station Number: 10~99
3-Digit Station Number: 100~999
4-Digit Station Number: 1000~9999
U
to clear all data when cursor is at setting position (Depends what length the
extension number has been assigned in MB1-2-03.)
Default Values
Not assigned.
4
Press
N
to write the data, and advance to the next A.A.No.
5
After the last entry, press
N
to write the data.
6
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Refer to
Chapter 2, Guide to Feature Programming.
N
1. Extension number cannot be the same as the physical extension, CAR, ACD/UCD/SCD pilot number.
2 1 : A A M S G 1
=
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data
A.A. Msg.
No.
1~8