166 – Chapter 1
DRAFT 3
Automated Attendant First Digit PBR Release Timer Selection, 1-4-01
December 2004
NEC Business Solutions Ltd
Doc.
No.: 8194 -
Release 2.0
Dece
mber 2004
1-4-01
System Mode
1
Submode
4
Data No.
01
PC Programming
+ AU
Automated Attendant First
Digit PBR Release Timer
Selection
General Description
Use this Memory Block to specify the time a Push Button Receiver (PBR) circuit remains
connected after the Automated Attendant message is played when a calling party calls in through
an Automated Attendant trunk.
With IPK R2000 and above, this memory block allows flexible entry and four Classes.
For R2000 only.
For R2000 and above.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates
the default setting.
5 sec.
10 sec.
20 sec.
30 sec.
LK 5
LK 6
LK 7
LK 8
40 sec.
50 sec.
60 sec.
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4
+
KA
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4
+
KA
to access the Memory Block.
0 1 : A A
P B R T I M E 2 0 s
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data
0 1 : A A
P B R R L S
2 0 s
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data