Connecting the
systems
After installing all of the required hardware on the voice messaging system,
perform the following procedure to connect the phone system to the messaging
system.
To install required voice messaging system hardware, such as D/82 boards, see the
Installation Guide.
System connections
To connect the phone system and
1
Connect the phone system digital lines 1-8 (or 1-4 on a 4-port system) to a
type 66 interconnect block. See the “D82 two-wire pinouts” table below for
cabling requirements.
2
Connect an 25-pair PBX station interface cable to an amphenol connection
on the type 66 interconnect block.
3
Connect the other end of the PBX station interface cable to a digital cable.
4
Connect the other end of the digital cable to a D82 board installed in the
UM8500 server.
5
Repeat steps
for each additional D82 board installed.
D82 Two-wire pinouts
Phone line
number
Type 66
Block pair
Pin
number
Pair color
Lead
designation
1
2
27
2
white-orange
orange-white
T1
R1
2
4
29
4
white-brown
brown-white
T2
R2
3
6
31
6
red-blue
blue-red
T3
R3
4
8
33
8
red-green
green-red
T4
R4
5
10
35
10
red-slate
slate-red
T5
R5
6
12
37
12
black-orange
orange-black
T6
R6
7
14
39
14
black-brown
brown-black
T7
R7
8
16
41
16
yellow-blue
blue-yellow
T8
R8
Содержание UNIVERGE UM8500
Страница 1: ......
Страница 28: ...UNIVERGE UM8500 INTEGRATION GUIDE 18 ...
Страница 62: ...UNIVERGE UM8500 INTEGRATION GUIDE 52 ...
Страница 68: ...UNIVERGE UM8500 INTEGRATION GUIDE 58 ...
Страница 94: ...UNIVERGE UM8500 INTEGRATION GUIDE 84 ...
Страница 104: ...UNIVERGE UM8500 INTEGRATION GUIDE 94 ...
Страница 114: ...UNIVERGE UM8500 INTEGRATION GUIDE 104 ...
Страница 120: ...UNIVERGE UM8500 INTEGRATION GUIDE 110 ...
Страница 126: ...UNIVERGE UM8500 INTEGRATION GUIDE 116 ...
Страница 146: ...UNIVERGE UM8500 INTEGRATION GUIDE 136 ...
Страница 164: ...UNIVERGE UM8500 INTEGRATION GUIDE 154 For a SPADLIC A trunk board ...
Страница 172: ...UNIVERGE UM8500 INTEGRATION GUIDE 162 ...
Страница 188: ...UNIVERGE UM8500 INTEGRATION GUIDE 178 ...
Страница 193: ...NEC NEAX 2400 OR NEC SV7000 WITH LAN MCI 183 For a SPADLIC A trunk board ...
Страница 222: ...UNIVERGE UM8500 INTEGRATION GUIDE 212 ...
Страница 230: ...UNIVERGE UM8500 INTEGRATION GUIDE 220 ...
Страница 276: ...UNIVERGE UM8500 INTEGRATION GUIDE 266 ...
Страница 290: ...UNIVERGE UM8500 INTEGRATION GUIDE 280 ...
Страница 302: ...UNIVERGE UM8500 INTEGRATION GUIDE 292 ...
Страница 312: ...UNIVERGE UM8500 INTEGRATION GUIDE 302 ...
Страница 336: ...UNIVERGE UM8500 INTEGRATION GUIDE 326 ...
Страница 342: ...UNIVERGE UM8500 INTEGRATION GUIDE 332 ...
Страница 346: ...UNIVERGE UM8500 INTEGRATION GUIDE 336 ...
Страница 352: ...UNIVERGE UM8500 INTEGRATION GUIDE 342 ...