Chapter 2: Server Installation

 

 

 

 
 
 

 

 

 

Figure 2-5. Installing the Server into a Rack

 

 

Note: 

Figure is for illustrative purposes only. Always install servers to the bottom of a rack first.

 

 

Note:

 Confirmation of the installation of this equipment is confirmed with a universal pitch rack. 

(EIA-310D) 

 

Содержание SX-Aurora TSUBASA A300-2

Страница 1: ...SX Aurora TSUBASA A300 2 USER S GUIDE Revision 1 0b ...

Страница 2: ...LL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA The products sold by NEC are not intended for and will not be used in life support systems medical equipment nuclear facilities or systems aircraft aircraft devices aircraft emergency communication dev...

Страница 3: ...your system to work properly please follow the links below to download all necessary drivers utilities and the user s guide for your server NEC product manuals http www nec com en global prod hpc aurora document Product safety info http www nec com en global prod hpc aurora document safety_information pdf This Guide may be periodically updated without notice Please check the NEC website for possib...

Страница 4: ...2 2 Preparing for Setup 15 Choosing a Setup Location 15 Rack Precautions 15 Server Precautions 16 Rack Mounting Considerations 16 2 3 Installing the Rails 18 Identifying the Sections of the Rack Rails 18 Installing the Optional Inner Rail Extensions 19 Assembling the Outer Rails 19 Installing the Outer Rails onto the Rack 20 Sliding the Chassis onto the Rack Rails 21 Chapter 3 Maintenance and BIOS...

Страница 5: ...amaged in any way If any equipment appears damaged please file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated It will also require a grounded AC power outlet nearby Be sur...

Страница 6: ...hassis Supermicro SC118GTS 1K43BP CPU Supports single Intel Xeon 6148 6126 4108 Socket P0 LGA3647 processor Socket Type Socket P0 LGA3647 Memory 48GB or 96GB Chipset PCH C621 PCIe Cards Up to two Vector Engine 1 0 cards Up to one InfiniBand HCA card Hard Drives One 2 5 hard drive Power Single 1400W power supply Form Factor 1U rackmount Dimensions WxHxD 17 2 x 1 7 x 28 5 in 437 x 43 x 724 mm Host S...

Страница 7: ...operating 6 RESET Button HW reset 7 Power Button The main power button is used to apply or remove power from the power supply to the server Turning off system power with this button removes the main power but maintains standby power To perform many maintenance tasks you must also unplug system before servicing Information LED Status Description Continuously on and red An overheat condition has occ...

Страница 8: ...d on the front of the chassis 1 2 3 2 2 4 4 Figure 1 2 Chassis Front View Front Chassis Features Item Feature Description 1 Power Supply 1400W power supply 2 Drive Carriers Hot swap 2 5 hard disk drive carriers 3 Control Panel Front control panel with LEDs and buttons see preceding page 4 Rack Ear Brackets Attaches server chassis to the rack 4 4 ...

Страница 9: ... Chassis Features Item Feature Description 1 Vector Engine Card Slots Slots for Vector Engine Cards left side and right side 2 I O Backpanel Rear I O ports see Section 1 6 for full details 3 PCI Card Slot Slot for one expansion card requires pre installed riser card 4 Power Supply AC power connection 5 Rack Ear Brackets Attaches server chassis to the rack 4 5 5 2 ...

Страница 10: ...B3 0 3 4 USB2 0 8 9 USB3 0 6 USB2 0 10 USB3 0 1 2 USB2 0 13 14 SPI SPI USB 3 0 Front USB3 0 x 2 Type A USB3 0 Rear USB3 0 x 2 Figure 1 4 Intel PCH C621 Chipset System Block Diagram Note This is a general block diagram and may not exactly represent the features on your motherboard See the Setciton 1 3 System Features for the actual specifications of your motherboard A 1 VCCP0 SNB CORE PECI 30 DDR I...

Страница 11: ...LAN 4 LAN1 7 USB1 2 USB5 3 0 5 LAN2 8 VGA Port 3 USB4 3 0 6 USB0 9 UID Switch LED VGA Port A video VGA port is located next to USB1 on the I O back panel Refer to the board layout below for the location LAN Ports Two Gigabit Ethernet ports LAN1 LAN2 are located on the I O back panel In addition a dedicated IPMI LAN is located above USB4 5 All of these ports accept RJ45 cables Please refer to the L...

Страница 12: ...nel USB 0 1 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_N 6 USB_N 3 USB_P 7 USB_P 4 Ground 8 Ground Front Panel USB 2 3 4 5 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 2 5V 3 USB_N 4 USB_N 5 USB_P 6 USB_P 7 Ground 8 Ground 9 Key 10 NC Back Panel USB 6 7 3 0 Pin Definitions Pin Definition Pin Definition A1 VBUS B1 Power A2 D B2 USB_N A3 D B3 USB_P A4 GND B4 GND A5 S...

Страница 13: ... the back panel The UID LED is located next to the UID switch When you press the UID switch the UID LED will be turned on Press the UID switch again to turn off the LED indicator The UID Indicator provides easy identification of a system unit that may be in need of service UID Switch Pin Definitions Pin Definition 1 Ground 2 Ground 3 Button In 4 Button In UID LED Pin Definitions Color Status Blue ...

Страница 14: ...fication of a system unit that may need service UID LED LED Indicator LED Color Definition Blue On Unit Identified IPMI LAN LEDs In addition to LAN1 and LAN2 an IPMI LAN is also located on the I O back panel The amber LED on the right indicates activity while the green LED on the left indicates the speed of the connection Refer to the table below for more information Link LED IPMI LAN Activity LED...

Страница 15: ...here heat electrical noise and electromagnetic fields are generated Leave enough clearance in front of the rack so that you can open the front door completely 25 inches and approximately 30 inches of clearance in the back of the rack to allow sufficient space for airflow and access when servicing This product should be installed only in a Restricted Access Location dedicated equipment rooms servic...

Страница 16: ... in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers panels on the servers closed to maintain proper cooling Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment ma...

Страница 17: ...ttention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rac...

Страница 18: ...ackage includes two sets of rack rails one set for the right side of the chassis and one for the left Each set consists of an inner rail that is fixed directly to the chassis and an outer rail that attaches to the rack The inner rails are pre attached and do not interfere with normal use of the chassis if you decide not to install it into a rack Inner Rail pre attached to the chassis Inner Rail Ex...

Страница 19: ... the hooks until the quick release bracket snaps into place securing the extension to the chassis 3 If desired you can install a screw to further secure the extension to the chassis 4 Repeat for the other inner rail extension Figure 2 2 Installing the Optional Inner Rail Extensions Assembling the Outer Rails Each outer rail comes in two sections that must be assembled before mounting onto the rack...

Страница 20: ...removed and you must use screws to secure the rail to the rack Outer Rail Installation 1 Align the square pegs on the front end of the rail with the square holes on the front of the rack C Push the rail into the rack until the quick release bracket snaps into place securing the rail to the rack Keep the rail horizontal 2 Adjust the rail to reach just past the full depth of your rack 3 Align the sq...

Страница 21: ...you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over Sliding the Chassis onto the Rack Rails Installing the Chassis into a Rack 1 Align the chassis rails with the front of the rack rails 2 Slide the chassis rails into the rack rails keeping the pressure even on both sides The spring latch engages when the chassis is part way in Push the server completel...

Страница 22: ...2 5 Installing the Server into a Rack Note Figure is for illustrative purposes only Always install servers to the bottom of a rack first Note Confirmation of the installation of this equipment is confirmed with a universal pitch rack EIA 310D ...

Страница 23: ...A BIOS Codes Chapter 3 Maintenance and BIOS Setting 3 1 Overview About maintenance and BIOS setting only trained and qualified personnel of NEC system should be allowed to install replace or service this equipment ...

Страница 24: ...inue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The table shown below lists some common errors and their corresponding beep codes encountered by users BIOS Beep POST Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset R...

Страница 25: ...rning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents 警告の定義 この警告サインは危険を意味します 人身事故につながる可能性がありますので いずれの機器でも動作させる前に 電気回路に含まれる危険性に注意して 標準的な事故防止策に精通して下さい Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefa...

Страница 26: ...ruction situé à la fin de chaque avertissement CONSERVEZ CES INFORMATIONS Circuit Breaker Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 250 V 20 A サーキット ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないことを確認下さい Warnung Dieses Produkt ist darauf angewiesen dass im Gebäud...

Страница 27: ...tended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warning does not apply to workstations アクセス制限区域 このユニットは アクセス制限区域に設置されることを想定しています アクセス制限区域は 特別なツール 鍵と錠前 その他のセキュリティの手段を用いてのみ出入りが可能 です Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen ...

Страница 28: ...e Verbindungen entfernt werden Attention Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes 地方および国の電気規格に準拠 機器の取り付けはその地方および国の...

Страница 29: ...l laws and regulations 製品の廃棄 この製品を廃棄処分する場合 国の関係する全ての法律 条例に従い処理する必要があります Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et ou directives de respect de l environnement Renseignez vous auprès de l organisme compétent ...

Страница 30: ...stellten Verbindungskabeln Stromkabeln und oder Adapater die Ihre örtlichen Sicherheitsstandards einhalten Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Geräten oder Produkten die nicht mit NEC gekennzeichnet sind Attention Lors de l installation du pr...

Отзывы: