Care and maintenance of the air conditioner

CAUTION: Before performing any maintenance, turn off the main power to the system.

Indoor Unit

Grille, Case, and Remote Control

Turn the system off before cleaning. To
clean, wipe with a soft, dry cloth. Do not
use bleach or abrasives.

NOTE:

Supply power must be disconnected before
cleaning the indoor unit.

Air Filters

The air filters behind the front grille should
be checked and cleaned once every 2
weeks or more often if neccessary.

Never use any of the followings:

• Water hotter than 40°C

Could cause deformation and/or discoloration.

• Volatile substances

Could damage the surfaces of the air
conditioner.

Lift the front access panel and pull the filter tab
slightly forward to remove the filter.

Clean the filter with a vacuum or warm, soapy
water.

• If dirt is conspicuous, wash with a solution of

detergent in lukewarm water.

• If hot water (40°C or more) is used, it may be

deformed.

After washing with water, dry well in the shade.

Re-install the air filter.

Vertical louver Horizontal louver

Air filters (behind front panel)

Remote control storage
(behind front panel)
:except 7k, 9k model

Air outlet vent

Air inlet vent

Gasoline

P owder

1

2

3

4

Air Purifying Filters(Option)

This filter consists of two filters. One is electrostatic filter to remove very fine dust as small as 0.1
micron such as tobacco smoke and pollen etc., the other is deodorant filter to remove unpleasant
smell such as food, sweat, and fungus.

Electrostatic filter

Deodorant filter

(Air Purifying System)

Air purifying filter

Air filter

(1) 

A30045A(w fl+) 

 

 

1994.10.12 

12:37 

PM 

 

’. 3 319

Содержание RSH2423S

Страница 1: ...3S OWNER S MANUAL Before using your air conditioner please read this manual carefully and keep it for future reference Prior to installation this air conditioning unit must be submitted for approval b...

Страница 2: ...eshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all Contact the authorized Service technician for repair or maintenance of this unit Contac...

Страница 3: ...atmosphere In case gas leaks the gas may accumulates the unit and it may cause fire ignition Confirm drainage piping is connected properly If it is not connected perfectly it may cause water leakage...

Страница 4: ...ll cause electrical shock or fire due to heat generation Do not operate with wet hand It may cause electrical shock Do not insert anything into the air inlet air outlet Since the fan rotates at high s...

Страница 5: ...ff and turn off the circuit breaker Since the fan rotates at high speed during operation it may cause an injury Do not put a pet or house plant where it will be exposed to direct air flow This could i...

Страница 6: ...taining the unit It may cause an injury etc by falling down Do not leave on installation stand which is damaged The unit may drop or fall down and cause an injury Do not insert hands through vanes whe...

Страница 7: ...TTING BUTTONS Used to adjust the time TIMER SET CANCEL BUTTONS Used to set the timer when the desired time is obtained and to cancel the Timer operation CHAOS SWING BUTTON Used to stop or start louver...

Страница 8: ...ect the operation mode ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low medium high or CHAOS JET COOL Used to s...

Страница 9: ...oor System Slide Switch Operation Refer to page 18 FORCED OPERATION Used for operation when the remote control cannot be used AUTO RESTART In case the power comes on again after a power failure the ai...

Страница 10: ...ation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow Close the door on the remote control Set the temperature low...

Страница 11: ...the door on the remote control and press the Room Temperature Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will then be...

Страница 12: ...f you select the dehumidification mode on the operation selection button the A C starts to run the dehumidification function automatically setting the room temp and airflow volume to the best conditio...

Страница 13: ...oor on the remote control Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in 1 C increments Set the fan speed again with the door of the rem...

Страница 14: ...rate in high fan speed on cooling mode NOTE During the JET COOL function at any moment the A C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp automatically to...

Страница 15: ...Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time Press the Time Setting buttons until the desire...

Страница 16: ...ight Horizontal Airflow direction Caution Ensure unit is turned off before adjusting the horizontal airflow direction control Carefully open vertical louver to allow access to the horizontal airflow d...

Страница 17: ...n speed is shifted from low to CHAOS and back to low again NOTE CHAOS Air economizes power consumption and prevents overcooling The fan speed is automatically changed from high to low or vice versa de...

Страница 18: ...n If you want to stop operation move the Slide Switch to the Auto Restart or the Remote Control position In case the power comes on again after power failure on the Forced Operation position the opera...

Страница 19: ...ner Lift the front access panel and pull the filter tab slightly forward to remove the filter Clean the filter with a vacuum or warm soapy water If dirt is conspicuous wash with a solution of detergen...

Страница 20: ...reducethe operatingefficiency of thesystem andcause higher operating costs Side Rear Piping Drain Hose Air intake vents Air outlet vents Side Rear Drain Hose Air intake vents Air outlet vents Piping S...

Страница 21: ...tioner is not going to be used for a long time When the air conditioner is to be used again Turn off the circuit breaker and disconnect the plug Remove the batteries from the remote control When the a...

Страница 22: ...let direct sunshine enter the room when the air conditioner is in operation Clean the air filter regularly Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects Cl...

Страница 23: ...oes not operate for about 3 minutes when restarted Does not cool or heat effectively The air conditioner operation is noisy Remote control display is faint or no display at all Crack sound is heard Is...

Страница 24: ...P No 3828A30045A Printed in Korea...

Отзывы: