CHAPTER 8 STANDBY FUNCTION
216
User’s Manual U10676EJ3V0UM
8.1 Settings and Operating Statuses of Standby Mode
Table 8-1. Operating Statuses in Standby Mode
STOP Mode
HALT Mode
Instruction to be set
STOP instruction
HALT instruction
Operating status
Clock generator
Operation stopped
Only CPU clock
Φ
is stopped
(oscillation continues)
Basic interval timer/
Operation stopped
Operation possible
watchdog timer
BT mode: Sets IRQBT at reference
time intervals
WT mode: Generates reset signal
when BT overflows
Timer counter
Operation stopped
Operation possible
External interrupt
INT0 cannot operate
Note
INT2 can only operate at KRn fall.
CPU
Operation stopped
Release signal
• Reset signal
• Reset signal
• Interrupt request signal from hardware
• Interrupt request signal from hardware
in which interrupt is enabled
in which interrupt is enabled
• System reset signal (key return reset)
generated by KRn fall when KRREN
pin is 1
Note
Operation is possible only when the noise eliminator is not selected (when IM02 = 1) by bit 2 of the edge
detection mode register (IM0).
Содержание PD754144