56
CHAPTER 5. PERIPHERAL HARDWARE FUNCTIONS
Fig. 5-11 Processor Clock Control Register Format
Note
When using a calue of f
XX
such that 4.19 MHz < f
XX
≤
5.0 MHz, if maximum speed mode :
Φ
f
XX
/4 (PCC1, PCC0
= 11) is set as CPU clock frequency, 1 machine cycle is less than 0.95
µ
s and the standard minimum value
0.95
µ
s is not kept.
Therefore, is this case, PCC1, PCC0 = 11 cannot be set, so it should be used with PCC1, PCC0 = 00 or 10.
As a result, the combination of “f
XX
= 4.19 MHz, PCC1, PCC0 = 11” is maximum speed selection (1 machin
cycle = 0.95
µ
s) as CPU clock.
3
2
1
0
Symbol
FB3H
PCC3
PCC2
PCC1
PCC0
PCC
CPU clock selection bits when f
XX
≤
4.19 MHz
( ) : When f
XX
= 4.19 MHz
CPU Clock Frequency
1 Machine Cycle
0
0
Φ
Output = f
XX
/64 (65.5 kHz)
15.3
µ
s
0
1
Setting prohibited
–
1
0
Φ
= f
XX
/8 (524 kHz)
19.1
µ
s
1
1
Φ
= f
XX
/4 (1.05 MHz)
0.95
µ
s
When 4.19 MHz < f
XX
≤
5.0 MHz
( ) : When f
XX
= 4.19 MHz
CPU Clock Frequency
1 Machine Cycle
0
0
Φ
Output = f
XX
/64 (76.7 kHz)
13
µ
s
0
1
Setting prohibited
–
1
0
Φ
= f
XX
/8 (614 kHz)
1.63
µ
s
1
1
Setting prohibited
–
f
XX
: Main system clock oscillation circuit output frequency
CPU operating mode control bit
Address
0
0
Normal operating mode
0
1
HALT mode
1
0
STOP mode
1
1