117
CHAPTER 5 PERIPHERAL HARDWARE FUNCTIONS
(2) Timer/event counter time setting
[Timer setup time] (cycle) is found by dividing [modulo register co 1] by [count pulse (CP)
frequency] selected by setting the mode register.
n+1
T (sec) = = (n + 1) · (resolution)
f
CP
T (sec) : Timer setup time (seconds)
f
CP
(Hz) : Count pulse frequency (Hz)
n
: Modulo register content (n • 0)
Once the timer is set, interrupt request signal (IRQTn) is generated at the intervals set in the timer.
Table 5-6 lists the resolution and longest setup time (time when FFH is set in the modulo register) for each
count pulse to the timer/event counter.
Table 5-6. Resolution and Longest Setup Time
(a) When timer/event counter (channel 0)
Mode register
At 6.00 MHz
At 4.19 MHz
TM06
TM05
TM04
Resolution
Longest setup time
Resolution
Longest setup time
1
0
0
171 µs
43.7 ms
244 µs
62.5 ms
1
0
1
42.7 µs
10.9 ms
61.0 µs
15.6 ms
1
1
0
10.7 µs
2.73 ms
15.3 µs
3.91 ms
1
1
1
2.67 µs
683 µs
3.82 µs
977 µs
(b) When timer counter (channel 1)
Mode register
At 6.00 MHz
At 4.19 MHz
TM16
TM15
TM14
Resolution
Longest setup time
Resolution
Longest setup time
1
0
0
685 µs
175 ms
980 µs
250 ms
1
0
1
171 µs
43.7 ms
244 µs
62.5 ms
1
1
0
42.7 µs
10.9 ms
61.0 µs
15.6 ms
1
1
1
10.7 µs
2.73 ms
15.3 µs
3.91 ms
Содержание PD750004
Страница 8: ... MEMO ...
Страница 20: ... xii MEMO ...
Страница 234: ...214 µPD750008 USER S MANUAL MEMO ...
Страница 244: ...224 µPD750008 USER S MANUAL MEMO ...
Страница 248: ...228 µPD750008 USER S MANUAL MEMO ...
Страница 254: ...234 µPD75008 USER S MANUAL MEMO ...
Страница 328: ...308 µPD750008 USER S MANUAL MEMO ...
Страница 330: ...310 µPD750008 USER S MANUAL MEMO ...
Страница 342: ...322 µPD750008 USER S MANUAL MEMO ...