MTD-PL-028/141005
PASOLINK
+
155 MB 1+0/1+1 SYSTEM
- 25 -
7) Mechanical Dimension
ODU
: 240(W) x 243(H) x 124(D) : Approx. 5 Kg (Type 1)
: 260(W) x 410(H) x 190(D) : Approx. 10 Kg (Type 2)
IDU
1 + 0
: 482(W) x 44(H) x 292(D) : Approx. 5 Kg*
1 + 1
: 482(W) x 133(H) x 300(D) : Approx. 13 Kg*
Note*: Including option panel
Note : Salt damage
In case of operating in the sea or around the coast area (within 3 km from coastline),
measure must be taken for the ODU against salt damage. Please ask NEC for
countermeasure.
6.5
Events
Alarm Events for 1+0 system
Event
Event conditions
ALM indication
LED
LOS
Input signal lost (Input STM-1 signal)
LED on Module panel
LOF
Frame synchronization lost (Input STM-1 signal)
IDU ALM and LED on Module
panel
INTFC ALM
STM-1 interface unit failure, Loss of output STM-1 signal
IDU ALM and LED on Module
panel
BER (RX) ALM
Excessive BER
BER degraded worse than preset value (10e-3 to 10e-
5)
IDU ALM
MOD ALM
TX side alarm includes unit failure, IF output signal
degraded.
IDU ALM
DEM ALM
RX side alarm includes unit failure, IF signal input lost.
IDU ALM
WS ALM
Unit fail, WS input signal lost.
IDU ALM
TX PWR ALM
ODU transmitting power decreased
ODU ALM
TX IN ALM
Receiving TX IF signal level decreased
ODU ALM
RX IN ALM
Receiving signal level decreased
ODU ALM
APC ALM
ODU APC loop is out of lock
ODU ALM
MAINT ALM
LCT set to MAINT status
MAINT
6.6
Indication
LED Indication on the equipment front
Failure indication of the equipment unit to be replaced.
1+0 Equipment
LED indication
Condition
Color
MAINT
During Maintenance
Yellow
ODU ALM
ODU equipment failure
Red
IDU ALM
IDU equipment failure
Red
PWR
On power
Green
Содержание PASOLINK+
Страница 5: ...PASOLINK 155 MB 1 0 1 1 SYSTEM MTD PL 028 141005 iv This page is intentionally blank ...
Страница 11: ...PASOLINK 155 MB 1 0 1 1 SYSTEM MTD PL 028 141005 6 This page is intentionally blank ...
Страница 13: ...PASOLINK 155 MB 1 0 1 1 SYSTEM MTD PL 028 141005 8 This page is intentionally blank ...
Страница 25: ...PASOLINK 155 MB 1 0 1 1 SYSTEM MTD PL 028 141005 20 Figure 6 Interconnection of ODU and IDU 1 0 ...
Страница 34: ...MTD PL 032 1401005 NEC Coporation Tokyo Japan ...