DATA01 Target
00H : Use Point on Signal Change
01H : Picture mute during lens shift
DATA02 Setting Value
00H : Inactive
01H : Active
Response: At the time of a success
22H 21H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 same values as DATA01 of the command
DATA02 Results
00H : Normal
01H : Error
Response: At the time of a failure
A2H 21H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)
060. GAIN PARAMETER REQUEST 2
**********************************************************************
Function:
This command acquires the adjustment values.
Command:
03H 04H 00H 00H 03H DATA01 .. DATA03 CKS
(*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 .. 02 Acquirement items (!)
DATA03 00H fixed
Response: At the time of a success
23H 04H 01H xxH 0DH DATA01 .. DATA13 CKS
(*1) (*2)
(*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 Adjustment status
00H : Displaying impossible
01H : Adjustment impossible
02H : Adjustment possible
FFH : Selected gain is not available.
DATA02 Maximum adjustment value (Lower ranking 8 bits)
DATA03 Maximum adjustment value (Upper ranking 8 bits)
DATA04 Minimum adjustment value (Lower ranking 8 bits)
DATA05 Minimum adjustment value (Upper ranking 8 bits)
DATA06 Default adjustment value (Lower ranking 8 bits)
DATA07 Default adjustment value (Upper ranking 8 bits)
DATA08 Current value (Lower ranking 8 bits)