background image

(!2) Only the M300 series is compatible. 

[P350X/P350W/P420X Series]

STANDBY MODE: "POWER-SAVING"

Control Command

Serial 

port

Wired 

LAN port

Wireless 
LAN unit

POWER ON

Yes

No

No

Yes:    Supported
No: Not supported

 

 
==================================================================== 
 3. Interface Conditions 
---------------------------------------------------------------------- 
Serial connection 
---------------------------------------------------------------------- 
The communications method conforms to the RS-232C standard. 

Содержание NP-PH1000U

Страница 1: ...00 Series NP3150 NP1150 NP2150 NP3150 NP3151W Series NP4000 NP4000 NP4001 Series NP905 NP905 NP901W VT800 Series NP600 NP300 NP400 NP500 NP500W NP500WS NP600 NP600S Series VT VT770 Series VT70 VT37 VT...

Страница 2: ...le is required 3 4 LAN connection using a wireless LAN unit A wireless LAN unit is required Status of supported connection A USB cable is supplied as standard with the MT860 1060 1065 1075 The GT5000...

Страница 3: ...P420X Series STANDBY MODE POWER SAVING Control Command Serial port Wired LAN port Wireless LAN unit POWER ON Yes No No Yes Supported No Not supported 3 Interface Conditions Serial connection The commu...

Страница 4: ...No No No VT49 VT490 VT590 VT595 VT695 VT700 Yes No No No No No VT700 Yes No No No No No VT800 Yes No No No Yes No WT600WT 610 WT615 Yes Yes Yes Yes No No NP4000 NP4001 Yes No No No Yes No NP1250 NP22...

Страница 5: ...ON Yes No No PA600X PA550W PA500U PA500X Series STANDBY MODE NETWORK STANDBY Control Command Serial port Wired LAN port Wireless LAN unit POWER ON Yes Yes Yes Yes Supported No Not supported Baud rate...

Страница 6: ...and as an reply is referred to as a response The response has two types Acknowledge hereafter referred to as ACK that recognizes a command and Negative Acknowledge hereafter referred to as NAK that fa...

Страница 7: ...s is convenient for controlling multiple projectors at the same time When the controller is connected with the projector on a one to one basis Broadcast notification is recommended When the controller...

Страница 8: ...of data length The lower ranking 4 bits becomes the upper bits of data length Data length 12 Bit This is data length of data portion unit byte Command This sets data length of data added to a command...

Страница 9: ...This model is not compatible with the Switcher 03H This model is not compatible with the PC Viewer When a parameter error occurs 00H Unvalid values specified 01H Specified terminal is unavailable or c...

Страница 10: ...personal computer the USB connection may fail to operate When using a USB hub please use a self powered type not a bus powered type When using a USB hub connection to the first stage of the USB hub i...

Страница 11: ...H 07H BBH 039 LAMP MODE SET 03H B1H 00H 00H 02H 07H 00H BDH 046 WXGA MODE SETTING REQUEST 03H B0H 00H 00H 01H DATA1 CKS 049 WXGA MODE SETTING SET 03H B1H 00H 00H 02H DATA1 DATA2 CKS 050 REMOTE KEY COD...

Страница 12: ...0 24 NP4000 NP4001 NP4000 Series 25 NP905 NP901W VT800 NP900 Series 26 NP41 NP61 NP62 NP62 Series 27 NP300 NP400 NP500 NP500W NP500WS NP600 NP600S NP600 Series 28 GT1150 GT2150 GT50 Series 29 NP4100 N...

Страница 13: ...REQUEST 037 2 LAMP INFORMATION REQUEST 2 037 4 LAMP INFORMATION REQUEST 3 037 7 LAMP INFORMATION REQUEST 4 038 LAMP MODE REQUEST 039 LAMP MODE SET 046 WXGA MODE SETTING REQUEST 049 WXGA MODE SETTING S...

Страница 14: ...RUNNING STATUS REQUEST 078 3 INPUT STATUS REQUEST 078 4 MUTE STATUS REQUEST 078 5 MODEL NAME REQUEST 078 6 MIRROR COVER STATUS REQUEST 079 FREEZE CONTROL 110 AUTO FUNCTIONS EXECUTE 111 AUTO ADJUST EXE...

Страница 15: ...ER On the HT1100 VT770 LT245 LT265 LT280 LT380 NP1000 NP2000 NP1150 NP2150 NP3150 NP3151W NP1250 NP2250 NP3250 NP3250W NP1200 NP2200 NP4000 NP4001 NP4100 NP4100W NP905 NP901W VT800 LT25 LT30 LT35 VT48...

Страница 16: ...eserved Bit 1 Projector status 0 Idling 1 Power On Bit 0 Reserved Response At the time of a failure A0H 81H 01H xxH 02H DATA1H DATA02 CKS 1 2 4 3 007 COMMON DATA REQUEST Function This command acquires...

Страница 17: ...IEWER 08H SLOT1 09H SLOT2 DATA09 Indication signal type Valid only when Type 2 of input terminal is 02H or 03H x0H NTSC3 58 x1H NTSC4 43 x2H PAL x3H PAL60 x4H SECAM x5H B W60 x6H B W50 x7H PALNM x8H N...

Страница 18: ...ster 10 18H RAMP WBRG 19H Blue Raster 60 1DH Cross Hatch 3 1 Supported Not supported 1 Only LT240K 260K Pattern ID Pattern Name PA600 01H Cross Hatch 02H Gray Bars 03H Raster 0 04H Raster 25 05H Raste...

Страница 19: ...ition 01H During execution DATA69 Status of operation 00H Idling 04H Power On 05H Cooling 06H Idling Error occurrence Other than above nondisclosure Internal use of code during a state transition peri...

Страница 20: ...9H NP400 10H 04H 09H NP300 10H 00H 10H NP610 10H 01H 10H NP510 10H 02H 10H NP510W 10H 03H 10H NP410 10H 05H 10H NP310 10H 07H 10H NP610S 10H 08H 10H NP510WS 10H 09H 10H NP410 10H 01H 11H NP2200 10H 02...

Страница 21: ...DATA01 DATA02 CKS 1 2 4 3 Selected input terminal Data 07 Data08 RGB or RGB1 5 1 01H RGB 01H RGB2 5 2 02H RGB 01H Video 1 01H VIDEO 02H S Video 1 01H S VIDEO 03H Component 2 02H COMPONENT 04H Compone...

Страница 22: ...ife DATA02 Error Status 2 bit0 Lamp or Lamp1 has been used beyond its limit bit1 Formatter error bit2 Lamp2 error bit3 None bit4 None bit5 None bit6 None bit7 None DATA03 Error Status 3 bit0 None bit1...

Страница 23: ...OFF Function This command switches off the main power of the projector Command 02H 01H 00H 00H 00H 03H Response At the time of a success 22H 01H 01H xxH 00H CKS 1 2 3 Response At the time of a failure...

Страница 24: ...9H SLOT2 1 2AH SLOT2 2 CURRENT MODELS Terminal Number Terminal Name MT LT LT180 LT80 HT GT WT VT NP1000 3150 HT10 LT30 NP40 01H RGB1 RGB 02H RGB2 1 02H DVI ANALOG 2 06H Video 0BH S Video 10H Component...

Страница 25: ...picture Command 02H 10H 00H 00H 00H 12H Response At the time of a success 22H 10H 01H xxH 00H CKS 1 2 3 Response At the time of a failure A2H 10H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Supplement Pict...

Страница 26: ...nction This command cancels the sound muting Command 02H 13H 00H 00H 00H 15H Response At the time of a success 22H 13H 01H xxH 00H CKS 1 2 3 Response At the time of a failure A2H 13H 01H xxH 02H DATA0...

Страница 27: ...t decrement direct setting of contrast contrast increment decrement direct setting of sharpness sharpness increment decrement direct setting of tint tint increment decrement brightness contrast color...

Страница 28: ...3 contrast decrement value 1 DATA01 01H Contrast DATA02 FFH except Volume DATA03 01H increment decrement DATA04 FFH lower data 1 FFFF Hex DATA05 FFH upper data 1 FFFF Hex 030 2 VOLUME ADJUST Function...

Страница 29: ...H 00H Aspect Ratio Input DATA03 Adjustment mode 00H Absolute value specification 01H Relative value specification DATA04 Adjustment value Lower ranking 8 bits DATA05 Adjustment value Upper ranking 8 b...

Страница 30: ...t Ratio Auto NP4000 NP4100 Series 05H 00H Aspect Ratio 15 9 NP600 NP610 NP2200 NP216 P420 U300 V300 Series 05H 00H Aspect Ratio Full 06H 00H Aspect Ratio 16 10 NP600 NP610 NP2200 NP216 P420 U300 V300...

Страница 31: ...ojector Command 03H 8CH 00H 00H 00H 8FH Response At the time of a success 23H 8CH 01H xxH 10H DATA01 DATA16 CKS 1 2 3 Data Portion Contents DATA01 04 Lamp Hour Meter Normal mode second DATA05 08 Reser...

Страница 32: ...e A3H 94H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 037 4 LAMP INFORMATION REQUEST 3 Function This command acquires the information on the projector lamp in Eco mode Command 03H 96H 00H 00H 02H DATA01 DAT...

Страница 33: ...00H 00H 18000 seconds Calculator Procedure 1 Set calculator to HEX 2 Punch in DATA06 DATA05 DATA04 DATA03 00004650 3 Change from HEX to Decimal value will change to 18000 seconds Lamp s use of hours 1...

Страница 34: ...emaining time until inhibition of lamp usage in terms of specified values 11H Remaining time until inhibition of lamp usage in terms of Normal mode values 12H Remaining time until inhibition of lamp u...

Страница 35: ...of projector Command 03H B0H 00H 00H 01H 07H BBH Response At the time of a success 23H B0H 01H xxH 02H DATA01 DATA02 CKS 1 2 3 Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H Normal 0...

Страница 36: ...KS 1 2 3 Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H OFF 01H ON Response At the time of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 049 WXGA MODE SETTING SET Function T...

Страница 37: ...le Power On Command 02H 00H 00H 00H 00H CKS Response A2H 00H 01H 40H 02H DATA01 DATA02 CKS 7 Table of Response Error Codes DATA01 DATA2 00H 00H Unknown command 00H 01H This current model does not supp...

Страница 38: ...H 00H ZOOM DOWN 30 1EH 00H STORE 31 1FH 00H MUTE ALL OFF 37 25H 00H R 38 26H 00H G 39 27H 00H B 40 28H 00H OSD MUTE 41 29H 00H PICTURE 42 2AH 00H WHITE BAL 43 2BH 00H IMAGE 44 2CH 00H TEST 45 2DH 00H...

Страница 39: ...00H AUTO SHORT 222 DEH 00H AUTO LONG 223 DFH 00H PICTURE MANAGEMENT 225 E1H 00H COMPONENT 226 E2H 00H ZOOM POS UP HT 227 E3H 00H ZOOM POS DOWN HT 228 E4H 00H DVI DVI DIGITAL 6 229 E5H 00H LAN 232 E8H...

Страница 40: ...00H 02H DATA01 DATA02 CKS Data Portion Contents DATA01 DATA02 12H 00H Volume mute DATA01 DATA02 11H 00H Picture mute DATA01 DATA02 8AH 00H Picture freeze cycle aspect ratio 02H 0FH 00H 00H 02H DATA01...

Страница 41: ...ts DATA01 Same as DATA01 of the transmit data DATA02 to 05 Carbon Savings Kilogram Maximum 99999 kg DATA06 to 09 Carbon Savings Milligram Maximum 999999 mg Response At the time of a failure A3H 9AH 01...

Страница 42: ...ustment possible FFH Selected gain is not available DATA02 Maximum adjustment value Lower ranking 8 bits DATA03 Maximum adjustment value Upper ranking 8 bits DATA04 Minimum adjustment value Lower rank...

Страница 43: ...Black Correct Position 2CH 01H Black Correct Gain 2CH 02H Black Correct Inv Gain 2DH 00H Lamp Output 2EH 00H Signal Level Auto Control 2FH 00H Signal Level R G B Gain R 2FH 01H Signal Level R G B Gain...

Страница 44: ...ce 62H 00H Digital Zoom Zoom 62H 01H Digital Zoom Horizontal Position 62H 02H Digital Zoom Vertical Position 63H 00H White Bal Dual Brightness R 63H 01H White Bal Dual Brightness G 63H 02H White Bal D...

Страница 45: ...2 3 Data Portion Contents DATA01 Results 00H Normal 01H Error Response At the time of a failure A2H 1AH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Supplement Sound mute is cancelled in the following cases...

Страница 46: ...10H NP610 10H 01H 10H NP510 10H 02H 10H NP510W 10H 03H 10H NP410 10H 05H 10H NP310 10H 07H 10H NP610S 10H 08H 10H NP510WS 10H 09H 10H NP410 10H 01H 11H NP2200 10H 02H 11H NP1200 11H 00H 00H NP41 61 11...

Страница 47: ...nse At the time of a success 20H 85H 01H xxH 10H DATA01 DATA16 CKS 1 2 3 Data Portion Contents DATA01 02 Reserved DATA03 Projector status 00H Idling 01H Power On DATA04 Cooling processing 00H No execu...

Страница 48: ...tents DATA01 Selecting signal processing 00H No execution Normal condition 01H During execution DATA02 Signal number Entry list number 1 0 199 DATA03 04 Selected input terminal Terminal name DATA03 DA...

Страница 49: ...078 4 MUTE STATUS REQUEST Function This command acquires the status of the mute of projector Command 00H 85H 00H 00H 01H 03H 89H Response At the time of a success 20H 85H 01H xxH 10H DATA01 DATA16 CKS...

Страница 50: ...not available 02H 00H Available memory reservation error 02H 02H Operating memory 02H 03H Setting not possible 02H 04H On Forced on screen mute mode 02H 06H 02H 07H No signal 02H 08H 02H 09H No PC car...

Страница 51: ...98H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 097 196 WXGA MODE SETTING REQUEST Function This command acquires the setting of the WXGA Mode of projector Command 03H B0H 00H 00H 01H C3H 77H Response At the...

Страница 52: ...E BY SIDE if DATA02 is POSITION 01H 00H TOP LEFT 01H TOP RIGHT 02H BOTTOM LEFT 03H BOTTOM RIGHT if DATA02 is SOURCE 02H 00H OFF 01H VIDEO 02H S VIDEO Response At the time of a failure A3H B0H 01H xxH...

Страница 53: ...A3H B1H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 110 AUTO FUNCTIONS EXECUTE Function This command executes the auto functions Command 03H B6H 00H 00H 01H DATA01 CKS 3 Data Portion Contents DATA01 Executi...

Страница 54: ...ilure A3H BAH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 305 1 BASE MODEL TYPE REQUEST Function This command acquires the projector type Command 00H BFH 00H 00H 01H 00H C0H Response At the time of a succes...

Страница 55: ...H 09H NP500W FFH 10H 03H 09H NP400 FFH 10H 04H 09H NP300 FFH 10H 00H 10H NP610 FFH 10H 01H 10H NP510 FFH 10H 02H 10H NP510W FFH 10H 03H 10H NP410 FFH 10H 05H 10H NP310 FFH 10H 07H 10H NP610S FFH 10H 0...

Страница 56: ...Idle 04H Power On 05H Cooling 06H Idle Error Standby Other Not Support Other than above nondisclosure Internal use of code during a state transition period DATA03 Indicate Contents 00H Picture signal...

Страница 57: ...x2H PAL x3H PAL60 x4H SECAM x5H B W60 x6H B W50 x7H PALNM x8H NTSC3 58 LBX x9H NTSC3 58 SQZ xAH COMPONENT 60Hz xBH COMPONENT 50Hz xCH Un known xDH NTSC xEH PAL M xFH PAL N FFH Not Video Input Other No...

Страница 58: ...and 00H 01H 01H 00H Unvalid values specified 01H 01H 01H 02H Selected language is not available 02H 00H Available memory reservation error 02H 02H Operating memory 02H 03H Setting not possible 02H 04H...

Отзывы: