manualshive.com logo in svg
background image

 
 

 
 

© NEC Corporation 2016 

11 

0xa 

0x442 

Caution 

Scalable Persistent Memory backup media write error on Box %1 
Bay %2. Persistent data may have been lost. 

0xa 

0x443 

Caution 

Scalable Persistent Memory backup media read error on Box %1 
Bay %2. Persistent data may have been lost. 

0xa 

0x444 

Critical 

Scalable Persistent Memory arming error on %1, Logical 
NVDIMM %2.    The Logical NVDIMM could not be armed and 
future backups are not possible. 

0xa 

0x445 

Caution 

Scalable Persistent Memory backup device error on Box %1 
Bay %2. 

0xa 

0x449 

Caution 

Scalable Persistent Memory Address Range Scrub error threshold 
exceeded on %1, Logical NVDIMM %2. Logical NVDIMM 
Persistency is lost and future data backups are not possible. 

0xa 

0x452 

Critical 

%1 FW Communication Issue - Unable to communicate with %2 
FW. One or more configuration settings may be used from the 
last system boot. One or more configuration changes since the 
last boot may not have taken affect. 

0xa 

0x454 

Caution 

NVDIMM Error - Persistent Memory Address Range Scrub error 
threshold exceeded on Processor %1, DIMM %2 

(SN:%3

-%4-%5-

%6). NVDIMM Persistency is lost and future 

data backups are not possible. 

0xa 

0x455 

Caution 

IMPORTANT: The %1 in Bay %2 will soon be incapable of 
supporting the Scalable Persistent Memory backup. 

0xa 

0x456 

Critical 

IMPORTANT: The %1 in Bay %2 cannot support the Scalable 
Persistent Memory backup. Logical NVDIMM persistency has 
been lost. 

0xa 

0x460 

Caution 

Correctable Memory Error 

Threshold Exceeded (%1 %2, 

DIMM %3).

 

0xa 

0x461 

Caution 

High rate of corrected memory errors, performance may be 

degraded (%1 %2, DIMM %3).

 

0xa 

0x466 

Caution 

Memory Channel Error - Correctable Memory Error Threshold 

Exceeded (%1 %2, Channel %3).

 

0xa 

0x467 

Critical 

Uncorrectable Error was detected on Processor %1. 

0xa 

0x470 

Caution 

SATA device on Controller %1 Port %2 is unresponsive. 

0xa 

0x490 

Critical 

System Health Error.    A critical system health error requires the 

system to be shutdown. 

Содержание NEC Express5800 Series

Страница 1: ...NEC Express5800 iLO Embedded Server Notice for Express Report Service MG Revision 1 0 Nov 22 2017 NEC Corporation...

Страница 2: ...rence Sites 4 Words and Term 4 Revision History 4 1 Introduction 5 2 About NEC Express Report Service 6 3 NEC iLO IML SNMP Trap List 7 4 Precautions for Report Target Events 9 4 1 Events which doesn t...

Страница 3: ...er Corporation name and trade name are trademarks or registered trademarks Cautions Unauthorized copying of all or part of this manual is prohibited The contents of this manual may change in the futur...

Страница 4: ...service using the error information of the server from iLO using Express Report Service MG software NEC ESMPRO ServerManager Server management software It enables the integrative management of multip...

Страница 5: ...orporation 2016 5 1 Introduction This document describes the notice of NEC Express Report Service MG for NEC Express5800 Servers which has iLO on its mother board Please check the NEC iLO IML SNMP Tra...

Страница 6: ...ze NEC Express Report Service shown below NEC Express Report Service Agent software NEC ESMPRO ServerAgentService detects error information of the server and report to the Maintenance Company through...

Страница 7: ...Trap List NEC iLO IML SNMP Trap List is a list of IML and its SNMP trap information for NEC Express5800 iLO Embedded Servers Occurrence of each events is depends on the model or configuration of the...

Страница 8: ...e sent from NEC ESMPRO ServerAgentService to NEC Service Center or not SNMP Trap Information Express Report Service MG Shows the information whether the item will be sent to NEC Service Center with Ex...

Страница 9: ...Sensor 2 Location 3 Temperature 4 0x2 0x2a Critical 1 Storage System Overheating 2Slot 3 Temperature Sensor 4 Location 5 Temperature 6 0x2 0x2b Critical 1 Overheating Temperature Sensor 2 Location 3 T...

Страница 10: ...Failure Battery Shutdown Event Code 0x 3 0xa 0x315 Critical An uncorrectable memory error was detected prior to this system boot 0xa 0x323 Caution 1 Dual microSD Device Error The microSD card in Slot...

Страница 11: ...One or more configuration changes since the last boot may not have taken affect 0xa 0x454 Caution NVDIMM Error Persistent Memory Address Range Scrub error threshold exceeded on Processor 1 DIMM 2 SN 3...

Страница 12: ...te 0xa 0x2408 Caution Slot 1 Error Firmware image recovery not successful 0xa 0x2410 Caution Slot 1 Error Controller I O timeout failure 0xa 0x2416 Caution 1 Error Controller firmware not ready 0xb 0x...

Страница 13: ...al KTI initialization error has been detected 1 Major Code 2 Minor Code 3 0x32 0x221 Critical Unknown Initialization Error The system has experienced a fatal initialization error 1 Major Code 2 Minor...

Страница 14: ...image could not be authenticated 0x32 0x462 Critical Uncorrectable Memory Error Threshold Exceeded 1 2 DIMM 3 The DIMM is mapped out and is currently not available 0x32 0x3011 Critical MemBIST MEMTEST...

Страница 15: ...CODE 0x1a FAN Failure Report is required 6035 Report Target SNMP Trap ID 6035 became and report target of Express Report Service MG because FAN Failure IML is an report target of Express Report Servi...

Страница 16: ...NEC Corporation 2016 16 End...