background image

CONFIGURATION GUIDE

 

– 

NEC Express5800/A2040b, A2020b, A2010b, A1040b 

NEC Corporation 

Revision 7.0 

– December 2014

 

45 

7.4  Internal Flash Memory 

Product Name/Description 

Part Number 

Internal Flash Memory

 

With this kit, EXPRESSBUILDER can be started from POST. 

NE3315-07 

NOTE: 

 

When this flash memory is ordered and shipped with the server, the data in the EXPRESSBUILDER is 
copied into this kit.   

 

When  this  flash  memory  is  ordered  and  shipped  separately,  the  data  must  be  copied  from  the 
EXPRESSBUILDER DVD to the flash memory after installing it in the server for use.   

 

 

 

Содержание NEC Express5800 Series

Страница 1: ...and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server The available models depend on sales regi...

Страница 2: ...A2040b 14 1 2 A2020b 15 1 3 A2010b 16 1 4 A1040b 17 1 5 COPT 18 2 CPU 19 A2040b min 2CPU max 4CPU A1040b min 1CPU max 4CPU 19 3 Memory 21 3 1 Memory Riser Card 21 3 2 Memory Configuration 22 Memory C...

Страница 3: ...nt Bezel 48 8 4 Cable Arm 49 8 5 Management Console Specifications 50 REFERENCES 51 CPU 51 Memory 51 Internal Drive 57 Server Management 60 PCI Slot Available Slots and Installation Limitations 61 PCI...

Страница 4: ...194VA 2150W 2194VA 2150W 2092VA 2050W 2092VA 2050W 2092VA 2050W 2296VA 2250W 2296VA 2250W 2347VA 2300W 2245VA 2200W 2245VA 2200W 2143VA 2100W 2143VA 2100W 2143VA 2100W 2347VA 2300W 2347VA 2300W 1435VA...

Страница 5: ...42VA 1413W 1442VA 1413W 1442VA 1413W 1442VA 1413W 1442VA 1413W 2169VA 2126W 2088VA 2046W 2088VA 2046W 2006VA 1966W 2006VA 1966W 2006VA 1966W 2169VA 2126W 2169VA 2126W 2220VA 2176W 2139VA 2096W 2139VA...

Страница 6: ...1033VA 1012W 1033VA 1012W 1033VA 1012W 1033VA 1012W 1033VA 1012W 1370VA 1343W 1330VA 1303W 1330VA 1303W 1289VA 1263W 1289VA 1263W 1289VA 1263W 1370VA 1343W 1370VA 1343W 1421VA 1393W 1381VA 1353W 1381V...

Страница 7: ...2242W 2186VA 2142W 2186VA 2142W 2084VA 2042W 2084VA 2042W 2084VA 2042W 2288VA 2242W 2288VA 2242W 2339VA 2292W 2237VA 2192W 2237VA 2192W 2135VA 2092W 2135VA 2092W 2135VA 2092W 2339VA 2292W 2339VA 2292W...

Страница 8: ...U FAN LED N NMI Button C PCI LED O RESET Button D MEM LED P UID LED E CPU LED Q UID Button F VLT TMP LED Voltage Temperature R SYSTEM POWER LED G CNFG LED Configuration S SYSTEM POWER Button H MISC LE...

Страница 9: ...us LED 1 K MGB 2 Maintenance LAN Connector 1 D PCI Slots Low Profile L MGB 2 Management LAN Connector 1 E UID Button M SUVCable Connector 2 F MGB 1 RESET Button N Power Supply Unit G MGB 2 RESET Butto...

Страница 10: ...press5800 A2040b A2020b A2010b A1040b NEC Corporation Revision 7 0 December 2014 10 Dimensions mm A2040b A2020b A2010b A1040b In case of using slide rail attachment cable arm in use The above illustra...

Страница 11: ...ess5800 A2040b A2020b A2010b A1040b NEC Corporation Revision 7 0 December 2014 11 Configuration Diagram A2040b Legend Standard components Minimum required components A2020b Legend Standard components...

Страница 12: ...DE NEC Express5800 A2040b A2020b A2010b A1040b NEC Corporation Revision 7 0 December 2014 12 A2010b Legend Standard components Minimum required components A1040b Legend Standard components Minimum req...

Страница 13: ...8 socket Slot 15 PCI Express 3 0 x8 lane x8 socket Slot 16 PCI Express 3 0 x8 lane x8 socket NOTE Foa all PCI slot Low Profile 167 6mm in length PCI slot performance x4 lane for Slot 8 and 9 x8 lane f...

Страница 14: ...Supply Unit no OS NE3400 041F NOTE The base model must be ordered with processor kits memory riser cards memory kit power supply units and power cables Front Bezel and Cable Arm are not attached need...

Страница 15: ...4820v2 2 00 GHz 8C 16T 16 MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 025F NEC Express5800 A2020b 6C E7 4809v2 CTO 2x Intel Xeon Processor E7 4809v2 1 90 GHz 6C 12T 12 MB no RAM no HDD n...

Страница 16: ...sor E7 4820v2 2 00 GHz 8C 16T 16 MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 035F NEC Express5800 A2010b 6C E7 4809v2 CTO 1x Intel Xeon Processor E7 4809v2 1 90 GHz 6C 12T 12 MB no RAM n...

Страница 17: ...ocessor kits memory riser cards memory kit power supply units and power cables Front Bezel and Cable Arm are not attached need to be ordered separately if required Number of the available PCI Slots an...

Страница 18: ...d to the server NE3401 H011F NOTE Contact to our sales representative for software supporting COPT function When enabling CPU core or socket by Core Activation Key please purchase required software li...

Страница 19: ...GHz 12C 24T 30 MB NE3301 H003F Xeon E7 4830v2 Processor Kit 1x Intel Xeon Processor E7 4830v2 2 20 GHz 10C 20T 20 MB NE3301 H004F Xeon E7 4820v2 Processor Kit 1x Intel Xeon Processor E7 4820v2 2 00 GH...

Страница 20: ...cute Disable Technology to avoid the execution of malware utilizing buffer over flow error The maximum number of logical processors supported by OS See the table below for the maximum number of logica...

Страница 21: ...be mixed in one server For A1040b Product Name Description Part Number Memory Riser Card 16GB 32GB 64GB Memory Kit Module with 8x DIMM slots Hot plug not supported NE3302 H001 Memory Riser Card 16GB 3...

Страница 22: ...ry Mirroring Memory Configuration Feature Comparison See the table below for feature comparisons of memory configurations supported Independent Mode only Memory Rank Sparing under Independent Mode Mem...

Страница 23: ...MM 256GB 8GB RDIMM 512GB 16GB RDIMM 1024GB 32GB LRDIMM 2048GB 64GB LRDIMM Data Correction ECC DDDC Notes RDIMM and LRDIMM cannot be mixed RDIMM and LRDIMM cannot be mixed RDIMM and LRDIMM cannot be mi...

Страница 24: ...C NE3302 H010F 32GB MEM 2x16GB RDIMM 2x 16GB Registered DIMM DDR3L 1600 PC3L 12800 ECC NE3302 H011F Load Reduced DIMM LRDIMM 1600 MHz 64GB MEM 2x32GB LRDIMM 2x 32GB Load Reduced DIMM DDR3L 1600 PC3L 1...

Страница 25: ...NE3302 H010F 32GB MEM 2x16GB RDIMM 2x 16GB Registered DIMM DDR3L 1600 PC3L 12800 ECC NE3302 H011F Load Reduced DIMM LRDIMM 1600 MHz 64GB MEM 2x32GB LRDIMM 2x 32GB Load Reduced DIMM DDR3L 1600 PC3L 128...

Страница 26: ...Sparing 4 x 64GB LRDIMM 4x 32GB Load Reduced DIMM DDR3L 1333 PC3L 10600 ECC NE3302 H023F NOTE Not preinstalled Need to order at least 1 set 4x DIMM RDIMM and LRDIMM cannot be mixed in a server Logica...

Страница 27: ...istered DIMM DDR3L 1600 PC3L 12800 ECC NE3302 H030F 64GB MEM for Memory Mirroring 4 x 16GB RDIMM 4x 16GB Registered DIMM DDR3L 1600 PC3L 12800 ECC NE3302 H031F 128GB MEM for Memory Mirroring 4 x 32GB...

Страница 28: ...MHz Xeon E7 4830v2 E7 4820v2 Independent Mode RDIMM 8 16GB Up to 16 1066 MHz 1066 MHz LRDIMM 32GB Up to 16 1066 MHz 1066 MHz LRDIMM 64GB Up to 16 1066 MHz Lockstep Mode RDIMM 8 16GB Up to 16 1333 MHz...

Страница 29: ...Enterprise 1 Microsoft Windows Server 2008 R2 SP1 Datacenter 1 2 TB 2 TB Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard...

Страница 30: ...Drive Capacity x No of Drive 4 Y NOTE Needs to order RAID Controller to configure internal drives For RAID Configuration same type of internal drives need to be ordered within one RAID group pack Mult...

Страница 31: ...0b NEC Corporation Revision 7 0 December 2014 31 1x RAID Controller Configuration 2x RAID Controller Configuration 4 2 1 SAS HDD SSD 1GB Cache Flash 512MB Cache Battery 4 2 2 4 2 4 SAS HDD SSD 1GB Cac...

Страница 32: ...art Number Controller Need to order 1 RAID Controller 1GB RAID 0 1 5 6 10 50 60 LSI MegaRAID SAS 9270CV 8i with CV RAID0 1 5 6 10 50 60 1GB Cache Internal 8 port 4x2 connector PCIe 3 0 x8 SAS 6Gb s Fl...

Страница 33: ...ded Internal Drives Max 8 SAS HDD 300GB HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 512B sector NE3350 301 450GB HDD 1x450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 512B sector NE3350 322 600GB HDD 1x...

Страница 34: ...00 rpm 512B sector NE3350 304 900GB HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 512B sector NE3350 332 1 2TB HDD 1x1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm 512B sector NE3350 408 146 5GB HDD 1x 146...

Страница 35: ...HDD 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 512B sector NE3350 304 900GB HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 512B sector NE3350 332 1 2TB HDD 1x1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm...

Страница 36: ...luding writing software SATA NOTE Supported OS Windows Server 2008R2 and 2012 Included writing software supports the following OS Japanese ver Windows Server 2008 R2 SP1 Standard Windows Server 2008 R...

Страница 37: ...Performance PCIe 2 0 x1 Low Profile NE3304 138 1000BASE T Adapter 2 port Broadcom BCM5718 PCIe 2 0 x4 Performance PCIe 2 0 x1 Low Profile NE3304 132 1000BASE T Adapter 4 port Broadcom BCM5719 PCIe 2 0...

Страница 38: ...g and Failover without Standby Member feature Smart Load Balancing Auto Failback Disable with Standby Member feature FEC GEC Generic Trunking 2 ports in one card 2 ports among multiple cards Up to 2 p...

Страница 39: ...tween 1000BASE T card and 10GBASE SR card Not supported Concatct to our sales representative for other than Active backup Can mix 1000BASE T bonding and 10GBASE SR bonding within one system 6 2 Using...

Страница 40: ...or just below the server BTO configuration at the server delivery does NOT include RAID configuration Please do RAID configuration by using utility setting By using Flash Backup Unit Write Back is av...

Страница 41: ...site for the supported device and OS by iStorage series Please refer to the EXPRESSCLUSTER web site for cluster configuration The type and length of the cable depends on Fibre Channel FC link speed Pl...

Страница 42: ...contact to our sales representative for the delivery schedule 3GB main memory is required per one 1 1TB PCIe SSD This PCIe SSD is for NEC s solution set product Database Solution with Microsoft SQL Se...

Страница 43: ...3 4 3 4 Not available A2020b 1000W 2 3 4 Not available 800W 2 3 4 Not available A2010b 1000W 1 2 3 4 800W 1 2 3 4 A1040b 1000W 1 1 2 2 2 3 2 3 4 4 3 4 Not available 800W 1 2 2 3 4 3 4 3 4 Not availabl...

Страница 44: ...to the regulation in each geography 7 2 Redundant Fan Kit Product Name Description Part Number Redundant Fan 2x fan module standard NOTE 2 units are installed as standard no add on available Hot plug...

Страница 45: ...ernal Flash Memory With this kit EXPRESSBUILDER can be started from POST NE3315 07 NOTE When this flash memory is ordered and shipped with the server the data in the EXPRESSBUILDER is copied into this...

Страница 46: ...A K410 118 03 Switch Unit Connection Cable Set USB 5m 5 m 1 x 15 pin mini D sub to 1 x 15 pin mini D sub 1 x 4 pin USB A K410 118 05 Drawer w o KVM Drawer 17 inch LCD Console Unit 1U 17 inch LCD US 8...

Страница 47: ...nit Connection Cable Set USB 1 8m 1 8 m 1 x 15 pin mini D sub 1 x 15 pin mini D sub 1 x 4 pin USB A K410 118 1A Switch Unit Connection Cable Set USB 3m 3 m 1 x 15 pin mini D sub 1 x 15 pin mini D sub...

Страница 48: ...010b A1040b NEC Corporation Revision 7 0 December 2014 48 8 3 Front Bezel A2040b A2020b A2010b Product Name Description Part Number Front Bezel A2040b A2020b A2010b NE3446 H001 A1040b Product Name Des...

Страница 49: ...hown in the Dimensions For calculation considering LAN UTP without shield is 5mm in diameter at average 1x FC cable corresponds to 1x LAN cable 1x SAS cable corresponds to 2x LAN cables 1x SUV cable c...

Страница 50: ...t Explorer 10 0 Linux Firefox ESR17 Java Oracle Java JRE7 32bit version J2SE Runtime Environment Client OS Windows Windows Vista SP2 Windows 7 Windows 8 Windows Server 2003 R2 SP2 Windows Server 2008...

Страница 51: ...ing on the number of the installed CPU and the ordered Memory Riser Card Memory Riser Cards will be installed in the following priority order Need to install at least one Memory Riser Card of CPU Memo...

Страница 52: ...r Card Memory Riser Cards will be installed in the following priority order Need to install at least one Memory Riser Card of CPU Memory Riser Card Slot 1 2 3 4 5 6 7 8 2 1 3 2 4 5 7 6 8 1 3 A2010b Up...

Страница 53: ...er set NOTE Cannot mix RDIMM and LRDIMM in a server Lockstep Mode is a standard setting at the server delivery For DIMM installation priority order 1 to install larger DIMM first and 2 to install DIMM...

Страница 54: ...ockstep Mode Mirroring between memory pair on CH0 and CH1 AND memory pair on CH2 and CH3 NOTE Cannot mix RDIMM and LRDIMM in a server When using Memory Mirroring the available memory capacity becomes...

Страница 55: ...CH1 OR a memory pair on CH02 and CH03 is assigned as a spare memory rank NOTE Cannot mix RDIMM and LRDIMM in a server When using Memory Rank Sparing the available memory capacity reduces by the capac...

Страница 56: ...2 COPT Supported Model Standard BTO Configuration Centralized Mode Memory will be installed to the first younger 2 Memory Riser Cards Follows the same rule afterwards 3 COPT Supported Model With Cust...

Страница 57: ...ent capacity or mixing HDDs with the same rotation speed is supported in the BTO configuration Mixing HDDs with different rotation speed and mixing HDD and SSC is NOT supported in the BTO configuratio...

Страница 58: ...CONFIGURATION GUIDE NEC Express5800 A2040b A2020b A2010b A1040b NEC Corporation Revision 7 0 December 2014 58...

Страница 59: ...RAID 1 if the number of drive is odd will set one spare drive NE3303 168 or NE3303 173 Q ty 2 4 2 4 4 2 5 Up to 4 drives 1 RAID 0 Q ty 1 2 RAID 1 Q ty 2 3 4 RAID 1 if the number of drive is odd will...

Страница 60: ...te power capping BIOS BMC FW update Remote BIOS setup partial configuration only OS shutdown 1 Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Remote control via Web browser multi...

Страница 61: ...AN connection Need to separately order SFP Module NE3304 129 when necessary Fiber Channel Controller 2 port 16Gbps Optical Card Perf PCI Express 3 0 x8 1000BASE T Adapter 1 port Card Perf PCI Express...

Страница 62: ...to separately order SFP Module NE3304 129 when necessary Fibre Channel Controller 2 port 16Gbps Optical Card Perf PCI Express 3 0 x8 1000BASE T Adapter 1 port Card Perf PCI Express 2 0 x1 For LAN conn...

Страница 63: ...r 4 port can be installed When the number of available PCI slot is 13 up to 12x 1000BASE T Adapter 4 port can be installed AND PCI card requiring IO space should be 8 or less except RAID Controller Wh...

Страница 64: ...Slots PCI Slot Number of Available Slots per CPU configuration 4 9 13 16 1 Y Y Y Y 9 N Y Y Y 10 N N Y Y 14 N N N Y 3 Y Y Y Y 2 N Y Y Y 11 N N Y Y 15 N N N Y 4 Y Y Y Y 6 N Y Y Y 12 N N Y Y 16 N N N Y...

Страница 65: ...installed to Slot 9 or in case of 1CPU configuration Slot 5 External RAID Controller should be installed to Slot 5 8 12 or 16 Priority of PCI Cards Priority Product Number Product Name Description Sl...

Страница 66: ...Slots PCI Slot Number of Available Slots per CPU configuration 4 9 13 16 1 Y Y Y Y 9 N Y Y Y 8 N Y Y Y 16 N N N Y 12 N N Y Y 5 Y Y Y Y 2 N Y Y Y 14 N N N Y 10 N N Y Y 3 Y Y Y Y 11 N N Y Y 15 N N N Y...

Страница 67: ...Core De allocation EL6 4 x64 or later Y Y Y N 1 OL6 4x64 Y Y Y N 1 2012 R2 N N N N 2008R2 N N N N ESXi5 1u2 N N N N ESXi5 5 N N N N Dynamic Memory Page De allocation EL6 4 x64 or later Y Y Y N 1 OL6 4...

Страница 68: ...N N N 1 EL6 4x64 N N N N OL6 4x64 N N N N 2012 R2 TBD N N N 2008R2 N Y N N N 3 9 ESXi5 1u2 N N N N ESXi5 5 N N N N Dynamic COPT Core Sparing COPT Model EL6 5x64 Y N N N 1 EL6 4x64 N N N N OL6 4x64 N...

Страница 69: ...es are automatically installed 3 Please install the necessary module according to the documents Machine Check Monitoring Service User s Guide Capacity Optimization COPT User s Guide for Windows 4 inte...

Страница 70: ...countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a r...

Страница 71: ...71 Revision History Revision Date Description 1 0 February 2014 Initial Release 2 0 April 2014 Updates 3 0 June 2014 Updates RAS Feature Matrix 4 0 July 2014 Updates Windows Server 2012 R2 supported 5...

Отзывы: