NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 885
Data Interface - Automatic Answer - CCIS
D-65
D-65
Data Interface - Automatic Answer - CCIS
General Description
This feature allows a data terminal to automatically answer an incoming CCIS call without manual operation,
therefore, providing the capability of receiving electronic mail.
Operating Procedure
AUTOMATIC ANSWER for terminating data calls, Automatic Answer Mode can be set by the following
methods
1.
Set the Data Module DIP switch to the proper setting.
2.
Press the DISP/AUTO key of the D
term
to set the Data Adapter to Auto Answer ON.
3.
Set Automatic Answer when assigning attribute data via the D
term
/Data Adapter or MAT.
Service Conditions
1.
This feature can be cancelled at the data terminal by changing the DIP switch setting to Manual Answer
or by pressing the DISP/AUTO button of the D
term
again (the associated LED is extinguished).
2.
This feature can be activated even if the D
term
station is in the DO NOT DISTURB - CCIS [D-76] mode.
Interactions
1.
DATA INTERFACE-AUTOMATIC ANSWER for a Data Module is set via switch settings on the outside
of the Data Module.
2.
DATA INTERFACE-AUTOMATIC ANSWER may be programmed from the D
term
via attribute data,
thus saving a programmable line/feature key.
3.
When a Data Module is used between a Data Terminal and the PBX, certain character string sequences
relating to status are exchanged as call set up progresses.
4.
After a call connection is made, the Data Module looks for the ESC character followed by RELEASE as
a disconnect request from the DTE. The Data Module requests a disconnect from the PBX.
Programming
STEP 1:
ASDT
- Assign a Telephone Equipment Class (TEC) of 13 to an LEN associated with a DLC, Data
Adapter. An associated LEN will also be assigned as a TEC 12, D
term
. Assign a TEC of 16 to an LEN
associated with a DTL, Data Module.
STEP 2:
AKYD
- Assign the following data to an available key:
TN:
1
STN:
Station Number
TP:
Type of D
term
0/1:
RING:
0: No Ringing
1: Ringing All Lines
2: Ringing on Prime Line Only
3: Flexible Ring Assignment, enables RG parameter.
KYN: Key Number (1-40)
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...