CHAPTER 5
NDA-24299
Page 68
Revision 1.0
DATA PROGRAMMING
Assignment of FPC and MG and UNIT into Network
3. Assignment of FPC and MG and UNIT into Network
3.1 AFMU
Assign the module accommodation data by giving Module Group Number and Unit Number on an FPC
basis. This data is necessary to allocate unique Network ID (NID) to each MG/UNIT of the whole Fusion
network nodes.
Note:
This data can be set at the NCN only. A unique NID is assigned to each MG/UNIT automatically by entering
the AFMU data.
•
When the Fusion network is configured for the first time:
Enter the AFMU command data for all the Fusion network nodes (FPCs). Then, a unique NID is
assigned automatically to each MG/UNIT in the assigned order.
•
When the Fusion network is already configured and a module/unit is to be expanded:
Enter the AFMU command data related to the expanded module/unit. Then, a unique NID number, next
to the last existing NID number, is automatically assigned to the expanded module/unit.
shows an example data assignment for this particular network.
Figure 5-9 Assignment of Module Accommodation Data
The AFMU command display should look similar to
Figure 5-10 AFMU Command Display
M G =1
M G = 0
U 0
U 0
U 1
U 1
U 2
U 2
U 3
U 3
P B X
M G = 1
M G =0
U 0
U 0
U 1
U 1
U 2 U 3
P BX
M G = 0
U 0
U 1
U 2 U 3
P B X
M G =1
M G = 0
U 0
U 0
U 1
U 1
U 2
U 2
U 3
U 3
P B X
FP C = 1, M G = 0,
U N IT = 0
U NIT = 1
U NIT = 2
U NIT = 3
M G = 1 ,
U NIT = 0
U NIT = 1
U NIT = 2
U NIT = 3
FP C = 11 , M G = 0,
U N IT = 0
U NIT = 1
U NIT = 2
U NIT = 3
M G = 1 ,
U NIT = 0
U NIT = 1
U NIT = 2
U NIT = 3
FP C = 13 , M G = 0,
U N IT = 0
U NIT = 1
U NIT = 2
U NIT = 3
M G = 1 ,
U NIT = 0
U NIT = 1
FP C = 12 , M G = 0,
U N IT = 0
U NIT = 1
U NIT = 2
U NIT = 3
LN
N od e
B
LN
N od e
C
LN
No de
D
N od e A
N od e B
N od e C
N od e D
N C N
Data Assignm ent at N CN
FP C =1
FP C =12
FP C =11
FP C =13
N o de
A
M A T
M G (M o d u le G ro u p N u m b e r): 0 - 7
F P C (F u sio n P o in t C o d e ): 1 - 2 5 3
F P C
1
U N IT
1
M G
0
W R T?
Y
A FM U (A ssignm ent of F P C and M G and U N IT for N etw ork D ata M em ory)
M G (M o d u le G rou p N u m b er): 0 - 7
F P C (F u sio n P o in t C o d e ): 1 - 2 5 3
U (U n it N u m b e r): 0 - 3
Note:
For more information on each parameter, see the “Office Data Specification” manual.
Содержание NEAX 2400 IPX
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24299 ISSUE 1 STOCK 200776 Fusion Network System Manual ...
Страница 15: ...LIST OF TABLES NDA 24299 Page x Revision 1 0 This page is for your notes ...
Страница 73: ...CHAPTER 4 NDA 24299 Page 58 Revision 1 0 This page is for your notes ...
Страница 159: ...CHAPTER 5 NDA 24299 Page 144 Revision 1 0 DATA PROGRAMMING Office Data Sheets This page is for your notes ...