NEAX2000 IVS Retrofit System Guide
Page 30
ND-71075 (E), Issue 1.0
CHAPTER 3 LEN LAYOUT
LEN Layout for CP16 PIMABA-UA (2-PIM NEAX1000 IVS)
NOTE 1: Do not mount line/trunk circuit card with cabling in this slot; this slot has no connection
to the MDF via the backplane (LTC cables).
NOTE 2: When an 8-port line/trunk card, which requires cabling to MDF, is mounted in Slot 04,
Slot 05 must be left vacant or mounted with circuit cards
1
that do not interfere with the
8-port card mounted in LT04.
NOTE 3: When an 8-port line/trunk card, which requires cabling to MDF is mounted in Slot 06,
Slot 07 must be left vacant or mounted with circuit cards
1
that do not interfere with the
8-port card mounted in LT06.
NOTE 4: When using internal DTMF Receiver (4RST) on MP card, assign Card No. E200 to LEN
No. 0124.
NOTE 5: If single-line cards are mounted in LT or LT/AP slots, an external ring generator must
be connected to PWR0B. The system power supply does not provide these voltages.
It is recommended that the APR adapter be used in dual-port mode to provide for
single-line devices.
PIM 1
163
107
115
123
131
139
147
162
106
114
122
130
138
146
161
105
113
121
129
137
145
160
104
112
120
128
136
144
159
103
111
119
127
131
135
139
143
158
102
110
118
126
130
134
138
142
157
101
109
117
125
129
133
137
141
156
100
108
116
124
128
132
136
140
(LT00)
(LT01)
(LT02)
(LT03)
(LT04)
(LT05)
(LT06)
(LT07)
(LT08)
063
007
015
023
031
039
047
062
006
014
022
030
038
046
061
005
013
021
029
037
045
060
004
012
020
028
036
044
059
003
011
019
027
031
035
039
043
PIM 0
058
002
010
018
026
030
034
038
042
057
001
009
017
025
029
033
037
041
056
000
008
016
024
028
032
036
040
(LT00)
(LT01)
(LT02)
(LT03)
(LT04)
(LT05)
(LT06)
(LT07)
(LT08)
1. When an 8-port card is mounted in Slot 04/06, Slot 05/07 can only be mounted with the following cards:
SPN-AP00
SPN-AP01
SPN-ME00
SPN-SC01
SPN-SC02
SPN-4RSTB
SPN-4RSTB-911
SPN-4RSTC
SPN-CK00
SPN-CC00
PN-M03
SPN-SC03 (CSH)/(ICH)
Not Used
BS01
BS00