Precautions for Handling of Internal Devices 

 

 

 

 

 

Do not  disassemble,  repair, or modify the  product 
yourself 

Do  not  disassemble,  repair,  or modify  this  product.  Doing so may 
cause an electrical shock or a fire. Do not put the product close to 
fire, or immerse it in water. Doing so may cause an explosion. If the 
product  does  not  function  normally,  contact  your  service 
representative. 

 

 

Unplug all power cords 

Turn  the  power  off  and  unplug  the  power  before  removing  the 
computer's  cover.  Failure  to  do  so  could  endanger  you  and  may 
damage the adapter or computer 

 

Precaution on disposing or transferring 

 

-  Follow  the  ordinances  by  your  local  government  when  you are 

disposing  the  product.  Contact  the  local  government  for  more 
information. 

-  If  you  are  transferring  this  product  to  other  people,  be  sure  to 

transfer all items that come with the product including this guide 
along with the product. 

 

 

 

Ground  yourself  to  dissipate  any  static  charge 
before handling the adapter. 

To prevent any damage on components due to static electricity, 
make sure to discharge static electricity from yourself before you 
touch the adapter.

 

 

Don

t touch uncoated metal parts on adapter.

 

Never touch the 

adapter’s LAN port, terminals of components or 

uncoated metal parts on adapter. Otherwise, taint, erosion or 
others may cause loose connection.    Do not touch this product 
with wet or dirty hands.

 

 

Excessive force could break the connector. 

On installing this adapter, do not insert it by force.    Otherwise, the 
adapter and the server may be damaged.

 

 

Don

t  touch  the  tip  of  bracket  to  other  parts  of 

server 

When you insert the 4 adapter into expansion slot, be careful not to 
touch the tip of bracket to other parts of server (such as other 
components or board).    Otherwise, they may be damaged.

 

 

Firmly connect the network cable

 

When connecting the cable, insert the cable connector until you 
hear a click sound.

 

 

Limitations 

 

Supported OS 

For  OS  that  support  will  depend  on  the  device.  Please  refer  to  the  support 
matrix. 

Functions (NOT supported) 

-  For NE3304-133 a Wake On LAN is not supported 

OutOfBox, from Standby, from Sleep, from Hibernation, from suspend or any 
type of WOL 

Cables (NOT supported) 

-  For NE3304-133 a cable with boots is not supported. 

 

Description 

Side B

Side A

NE3304-132

NE3304-133

NE3304-138

1

1

1

2

2

2

3

3

3

4

4

4

1000BASE-T

Adapter

Dual Port 
1000BASE-T

Adapter

Quad Port 
1000BASE-T

Adapter

Side B

Side A

Side B

Side A

1. Bracket 

This product has 2 type of bracket. By default, Low-profile type is attached. If 
need to mount on Full-height PCI-EXPRESS slot, you can change to another 
bracket. See 

“Bracket Replacement”. 

2. LAN Port 

A  connector  provides  to  access  a  network.  For  the  types  of  connectable 
cables and how to connect, see “Network Cables”. Port id is numbered from 
“PORT1” to “PORT4”. See the figure. 

 

3. PCI-EXPRESS connector 

This  product  conformed  to  PCI  EXPRESS  2.0.  Supported  speed  is  5GT/s 
only. Each product has x4 lane edge. The logical lane size is as follows, 
NE3304-132, NE3304-138                    x1 lane 
NE3304-133                                          x4 lane 
This product can be installed to a slot more than x4 lane (or higher), and is 
compliant with PCI-EXPRESS 2.0 (or higher) specifications. 
 

NOTE: 

Check the PCI-EXPRESS slot which can be attached with reference 
to User’s Guide of Express Server before attaching this product. 

 

4. MAC Address 

MAC address of port1 is printed on the label. For port 2 or later, you can get 
by incrementing one to the address of the port1. 

N8104-138

SPEED

10=OFF
100=GRN
1000=ORG

LINK/ACT

N8104-132

1

2

SPEED

LINK/ACT

10=OFF
100=GRN
1000=ORG

N8104-133

1

4

ACT/LINK

Lamp

SPEED

Lamp

PORT1

PORT2

PORT3

PORT4

PORT1

PORT2

ACT/LINK

Lamp

SPEED

Lamp

NE3304-132

NE3304-138

NE3304-133

Port ID

Port ID

 

Lamp 

Lamp 

Status (color) 

Meaning 

SPEED 

On (Orange) 

Link at 1000Mbps speed. 

On (Green) 

Link at 100Mbps speed 

Off 

Link at 10Mbps speed 

LINK / 

ACT 

On (Green) 

Link is up 

Brink (Green) 

Traffic 

Off 

Link is down 

 

NOTE: 

If  the  system  is  in  sleep  state,  the  lamp  may  does  not  display 
correctly. Communications are not affected. 

 

 
 

Network Cable 

 

Connector 

RJ45   

Type 

Twisted Pair Cable( UTP / STP )    Must    be 4pair wiring   
Make sure you use cable that complies with the TIA-568 wiring 
specification. 

Cable 

Category 

10BASE-T: Cat.3 or better, 
100BASETX : Cat.5 or better 
1000BASE-T Cat.5e or better 

Length 

100 m (max.) 

 

Limitation of NE3304-133 

  Refer  to  the  left 
figure  which  does 
get  used  to  use  for 
the cable with boots 
(with  a  connector 
cover).   
*  The  cable  with 
boots  causes  of 
contact 

and 

connector 

 
 

Hardware Installation / Uninstallation

 

 
For hardware installation/uninstallation, r

efer to the User’s Guide of the server. 

IMPORTANT: 

- When  the  system  is  up,  please  turn  the  power  off  after 

shutdown process on the OS. and then unplug the AC power 
cord 

- For  rack-type  server,  before  open  the  top  cover,  need  to 

disconnect the cable from this product. 

 

Bracket replacement 

Depending  on  the  type  of  system,  installation  of  this  product  requires  either  a 
standard  bracket  or  a  low-profile  bracket.  NEC  provides  both  of  these  brackets 
with  the  product.  By  default  low-profile  bracket  is  attached.  Please  replace  the 
bracket according to the following steps as necessary. 
 

NE3304-132, NE3304-138 

Replacement

Bracket

(Different)

1

Remove the screw using a Philips screwdriver.

2

Remove a bracket from the adapter, Attache the different bracket.

Note: Keep the bracket was removed.

3

Fasten the screw using a Philips screwdriver.

Bracket

Screw

10

=O

FF

10

0=

G

R

N

10

00

=O

R

G

N

8

1

0

4

- 133

1

2

SPEED

LIN

K/A

C

T

Side-B

 

NE3304-133

 

2

3

1

Remove the screw using a Philips 
screwdriver.

Slide the bracket upward until it 
get stuck. (approximately 5mm)

Pull the bracket to outside, and remove it.

To remove a bracket

Note:  Keep the bracket was removed

2

1

Align the projections on the connector with the holes in the bracket, attach the 
brackets in the direction of the arrow(Orange).

Slide the bracket until it clicks .

To attach a bracket

projection

projection

Click
sound

3

Fasten the screw using a Philips 
screwdriver.

hole

   
 

Driver Installation / Uninstallation

 

 
To  use  this  product,  the  appropriate  LAN  driver  for  your  operating 
system must be installed. For detailed information, please install a driver 
with reference to the 

ExpressBuilder

 attached to the server. 

11.58

11.79mm

based on ISO standard.

The width of the root portion of a plug should 

use the cable within 12mm.

less than12mm

cable boots

Содержание NE3304-132

Страница 1: ...れるかなどについて説明されています 本書では危険の程度を表す言葉として 警告 と 注意 という用語を使用しています それぞれの用語は次の意味を持つものとして 定義しています 1 重傷とは 失明やけが やけど 高温 低温 感電 骨折 中毒などで後遺症が残るものおよび治療に入院 長期の通院を要する ものをさします 2 傷害とは 治療に入院や長期の通院を要さない けが やけど 感電などをさします 3 物的損害とは 家屋 家財および家畜 ペット等にかかわる拡大損害をさします 危険に対する注意 表示は次の 3 種類の記号を使って表しています それぞれの記号は次のような意味を持つものとして定義しています 表示例 指定以 外の ACコ ンセ ントに 差し 込ま ない 指定の電圧で 指定のACコンセントをお使いください 指定以外の電源を使うと火災や漏電の原因となります 注意を促す記 号 危険に対する 注意...

Страница 2: ...ブルの上にものを載せない ケーブルの接続がゆるんだまま使用しない 破損したケーブルを使用しない 適合するケーブルについては ケーブルについて を参照してください 腐食性ガスの存在する環境で使用または保管しない 腐食性ガス 二酸化硫黄 硫化水素 二酸化窒素 塩素 アンモニア オゾンなど の存在する環境に設置し 使用しな いでください また ほこりや空気中に腐食を促進する成分 塩化ナトリウムや硫黄など や導電性の金属などが含まれている環境へも設 置しないでください 製品内部のプリント基板が腐食し 故障および発煙 発火の原因となるおそれがあります 取扱および取り付け時の注意事項 分解 修理 改造はしない 本製品を分解したり 修理 改造を行ったりしないでください 感電や火災の危険があります 本体装置の電源コードを抜く 本体装置への取り付け 取り外しをするときには 必ず電源プラグをACコンセントから...

Страница 3: ...se T 100Base TX 1000Base T に対応しています ネットワークに接続する際 には 以下の仕様のケーブルをお使いください コネクタ RJ45 オス ケーブルタイプ ツイストペアケーブル UTP STP 8芯 4 ペア 規格 EIA TIA 規格準拠 使用される通信速度により要求されるケー ブルの品質が異なります 10Base T 100Base TX 1000Base T Cat 3 以上 Cat 5 以上 Cat 5e 以上 ケーブル長 最大 100m NE3304 133 に関する注意事項 11 58 11 79mm プラグ根元部の幅が 12mm以内 のものをお使いください プラグ根元部 プラグ先端部 12mm以内 ブーツ付き コネクタカバーつき のケーブルはご使用にな れませんのでご注意ください 上図を参照してケーブルをお 選びください ブーツ付きのケーブルが接続...

Страница 4: ...したりする 本製品の接続には ツイストペアケーブルを使用してくだ さい 特に 1000Mbps でお使いになる場合はカテゴリ 5e 以上のツイストペアケーブルを使用してください ま た ケーブルがしっかりと固定されていることを確認して ください 本製品とリンクパートナーの通信モード 全二重 半二重 が一致していることを確認してください ツイストペアケーブルを交換してみてください リンクパートナー上 ハブ スイッチ等 の別のポートを使 用してみてください ケーブルの配線環境にノイズ源 蛍光灯 電源線等 が近接 していないことを確認してください リンク ACT LNK ランプが点灯しない OS が正常に起動していることを確認してください 本製品およびリンクパートナー上の接続状態をすべて確 認してください ツイストペアケーブルを交換してみてください リンクパートナー上 ハブ スイッチ等 の別のポ...

Страница 5: ... section The following includes information necessary for proper and safe operation of the product Safety Indication Follow the instructions in this Startup Guide for your safety to use this product The server contains components with possible danger hazards that maycause by ignoring warnings and preventive actions against such hazards The words WARNING and CAUTION are used to indicate the degrees...

Страница 6: ... than x4 lane or higher and is compliant with PCI EXPRESS 2 0 or higher specifications NOTE Check the PCI EXPRESS slot which can be attached with reference to User s Guide of Express Server before attaching this product 4 MAC Address MAC address of port1 is printed on the label For port 2 or later you can get by incrementing one to the address of the port1 N8104 138 SPEED 10 OFF 100 GRN 1000 ORG L...

Страница 7: ...ink partner switch hub etc Check a setting or configuration on the link partner Make sure the link partner setting is correct If the setting is mis configured correct the setting If the partner s port is disabled enable it If the adapter s communication mode is set to full duplex mode make sure that the link partner s communication mode is also set to full duplex mode If these are set differently ...

Отзывы: