20 AIT Data Cartridge
Operation, Storage and Transportation
Requirements
■
Operation requirement
Temperature
: 5 to 45
°
C
Humidity
: 20 to 80 % (The maximum temperature of wet bulb is 26
°
C.)
Shelf time
: If an AIT data cartridge is exposed to an environment other than
the operating or storage environment, expose it to the operating
environment for a longer time than the period when it is exposed to
other environment (for 8 hours at maximum) before use. The
temperature gradient is 10
°
C/hour.
■
Storage requirement
Temperature
: 5 to 32
°
C
Humidity
: 20 to 60 % (The maximum temperature of wet bulb is 26
°
C.)
Storage condition
: Store an AIT data cartridge in a protective case with cover. You
can place the case horizontally or vertically.
■
Transportation requirement
Temperature
: -40 to 45
°
C
Humidity
: 5 to 80 % (The maximum temperature of wet bulb is 26
°
C.)
Temperature gradient
: 10
°
C/hour
Transportation condition : Store an AIT data cartridge in a protective case. During transporta-
tion, pack the case so that force will not apply to the AIT data
cartridge.
Label
It is recommended that you should affix a label to each AIT cartridge to associate the AIT data
cartridge with the backup data for easier identification.