2. Installation Procedure 

NEC Rack/Third Vendor Rack 

1. Verify the packed contents

3. Install a 5.25-inch devices in the Device Expansion Unit in the procedure below.

To install a 5.25-inch device in DEVICE1, use the latching rails (2) installed in the Device Expansion Unit 

(1) To install 5.25-inch devices in DEVICE2 - DEVICE4, 

remove the respective device bay covers.

(2) Install latching rails on the 5.25-inch device to be 

installed in the Device Expansion Unit. 

(3) Install the 5.25-inch device into the device bay. 

Push the device until a click occurs 

(7) Two or more workers hold the unit securely to mount it on the rack. 

(4) Fix the each of the outer rails by using M5 Millimeter screws(two at each of the front and rear, or four in 

total) and washers(two at each of the front and rear, or four in total).

Parts name 

Qty.

1

Device Expansion Unit

1

2

Latching Rail

4set

3

Rack Rail

2

4

M5 Millimeter Screw

8

5

M4 Millimeter Screw

6

6

Washer

8

7

Startup Guide(This manual)

1

8

CD

USER’S GUIDE

1

Verify the packed contents with the part list given below and ensure that all the 
components and parts are present. Also, check that each item is undamaged. If a 
component or part is missing or damaged, contact your dealer.

Do not touch the Device Expansion Unit during thunderstorms.

Do not touch any part of the Device Expansion Unit, including the 
cables, when a thunderstorm is approaching. Also, do not connect or 
disconnect any devices. There may be a risk of electric shock from 
lightning strike.

Do not place any object on top of the Device Expansion Unit.

The Device Expansion Unit may fall and cause property damage to the 
surroundings.

During Operation

Do not use a cellular phone or pager around the Device 
Expansion Unit.

Turn off the cellular phone or pager around the Device Expansion Unit.  
Radio interference may cause malfunctions of the Device Expansion 
Unit.

Keep any animal (pet) away from the Device Expansion Unit.

Pet's discharges or fur may enter the Device Expansion Unit and cause 
a fire or electric shock.

Do not pull out or remove the Device Expansion Unit from the 
rack.

Do not pull out or remove the device from the rack while the device is 
running. In addition to causing equipment to not function properly, 
separating the device from the rack may result in personal injury. 

(2) Loosen the eight screws fixing the slide bracket of each of the outer rails.

This is required to have the length of the outer rail be the same as the depth of the rack (or the distance 
between the front and rear supports).  If the screws are loosened, you can slide the slide bracket. 
If the depth of the rack is not enough, remove the two screws at the tip to extend the slide bracket.

Attach the screws which removed to the position of the figure.

Slide bracket

Stamp

Narrower distance 
between angle holes

Release lever

Plastic guide

Bearing rail

Inner rail

(3) Locate the outer rails on the frames of the rack.

(5) Fasten the screws loosened in step 1 to fix the slide bracket.

The contents of this document may be changed without notice. 

© NEC Corporation 2015 No copying or modifying without permission of NEC Corporation.

Printed on recycled paper. 

User’s guide in attached CD describe detailed explanation.

Do not attempt to lift the Device Expansion Unit only by yourself.

The Device Expansion Unit weighs max. 20 kg (depending on its 
hardware configuration). Always get more than one persons or use 
the lifter to install, disassembly, or carry the Device Expansion Unit. 
Carrying out these actions only by yourself may strain your back or 
drop the chassis to cause personal injury or damage of surrounding 
devices. Lift the Device Expansion Unit by firmly holding its bottom 
with other person.  

Do not install the Device Expansion Unit in any place other than 
specified.

Do not install the Device Expansion Unit in the following places or any 
place other than specified in this User's Guide.  Failure to follow this 
instruction may cause a fire.

a dusty place                                   

a place exposed to direct sunlight

a humid place such as near a boiler 

an unstable place

Installation, Relocation, Storage, and Connection

Do not install the Device Expansion Unit on rack with leaving 
covers removed.

Do not install the Device Expansion Unit on a rack with the cover being 
removed. Failure to follow this instruction not only may decrease the 
cooling effect in the Device Expansion Unit and result in some 
malfunction, but may also allow dusts to enter the Device Expansion 
Unit and result in a fire or electric shock. 

Be careful not to get your fingers caught in the rails or other 
components.

When mounting/removing the device onto/from the rack, be careful to 
avoid getting your fingers caught in the rails or cutting your fingers on 
the rails.

Do not use any unauthorized interface cable.

Use only interface cables provided by NEC and locate a proper 
device and a proper connector before connecting a cable. Using an 
authorized cable or connecting a cable to an improper destination 
may cause a short circuit, resulting in a fire.

Do not attempt to connect or disconnect the interface cable while 
the power cord is plugged into an outlet.

Make sure to power off the Device Expansion Unit and unplug the 
power cord from the power outlet before connecting/disconnecting the 
interface cable. If the Device Expansion Unit is powered off but its 
power cord is plugged to a power source, touching the cable may 
cause an electric shock or a fire resulted from a short circuit. Also, 
connect/disconnect the interface cable after turning off the power of 
the destination.

Also, observe the following notes on using and connecting an interface 
cable.
Do not use any damaged cable connector.  Before connecting an 
interface cable, confirm that any cable connector is not damaged and 
any connector pin is not bent or dirt.

Do not step on the cable.            

Do not place any object on the cable.

Do not use the Device Expansion Unit with loose cable connections.

Do not use the Device Expansion Unit with loose interface cable 

connections. After connecting the interface cable, secure it with a 
screwdriver or equivalent. To disconnect the interface cable, release the 
secured part and hold the connector and pull it straight out. 

Do not use the equipment in the place where corrosive gases exist.

Do not install the Device Expansion Unit in a place subject to corrosive 
gases including sulfur dioxide, hydrogen sulfide, nitrogen dioxide, 
chlorine, ammonia, and ozone. Do not install the Device Expansion Unit 
in an environment that contains dusts or chemicals that accelerate 
corrosion such as sodium chloride, sulfur, and conductive materials. 
Failure to follow this warning may cause the wires on the printed wiring 
board to short circuits, leading to fire. If you have any questions, 
contact the store where you purchased the product or a maintenance 
service company.

Do not close the ventilation hole.

Do not close fan or the front ventilation hole at the back of the Device 
Expansion Unit. Otherwise, its internal temperature will rise to cause 
malfunctions or a fire.

Do not apply any weight on the Device Expansion Unit when it is 
extended from the rack.

Do not apply any weight on the Device Expansion Unit when it is 
extended from the rack. Doing so may cause the frames to be bent, 
which makes it impossible to be mounted on the rack. It also may 
cause the Device Expansion Unit to fall, resulting in personal injury.

Do not work in the state installed to the rack.

Do not work in the state installed to the rack. Failure to follow this 
warning may cause an electric shock. Please work after removing from 
the rack. 

Do not carry or install the rack only by a single person.

More than one person is required to carry or install the rack.  Failure 
to follow this instruction may cause the rack fall to result in personal 
injury and/or breakage of surrounding devices.  In particular, a high 
rack is unstable if it is not fixed by stabilizers.  More than one person 
must always carry or install the rack while they support it.

Do not install with the load weight distributed unevenly

To avoid unevenly distributing the load of the rack and device, install a 
stabilizer or connect multiple racks to distribute the weight. Otherwise, 
the rack may fall, resulting in personal injury.

Notes on Installing and Accessing the Rack Cabinet 

Do not install components on the rack only by yourself.

Two or more people are required to install the rack components such 
as the door or rails. When installing the door, make sure that both 
upper and lower hinge pins are held in place. Failure to follow this 
instruction not only may cause some parts to fall but may also be 
broken and result in personal injury. .

Do not pull out a device from the rack if the rack is unstable.

Always pull out a device from the rack in the state that the rack is 
made stable (by the installation of stabilizers or earthquake-resistant 
construction).
Failure to follow this instruction may cause the rack to fall out and 
result in personal injury. 

Do not extend more than one device out of the rack.

Extending multiple devices from the rack may cause the rack to fall, 
resulting in personal injury. Extend only one device at one time.

When wiring for the rack, be sure not to exceed the rating of the 
power supply.

To prevent burns, fires, and device damages, the power supplied to 
the power supply in the rack shall not exceed the rating load of the 
power branch circuit.  Contact the local power company for the 
requirements on the wiring and installation of electric facilities.

Elevated Operating Ambient

If installed in a closed or multi-unit rack assembly, the operating 
ambient temperature of the rack environment may be greater than 
room ambient. Therefore, consideration should be given to installing 
the equipment in an environment compatible with the maximum 
ambient temperature (Tma) specified by the manufacturer.

Reduced Air Flow

Installation of the equipment in a rack should be such that the amount 
of air flow required for safe operation of the equipment is not 
compromised.

Mechanical Loading

Mounting of the equipment in the rack should be such that a 
hazardous condition is not achieved due to uneven mechanical loading.

Reliable Earthing

Reliable earthing of rack-mounted equipment should be maintained. 
Particular attention should be given to supply connections other than 
direct connections to the branch circuit (e.g., use of power strips).

Circuit Overloading

Consideration should be given to the connection of the equipment to 
the supply circuit and the effect that overloading of the circuits might 
have on overcurrent protection and supply wiring. Appropriate 
consideration of equipment nameplate ratings should be used when 
addressing this concern.

(1) Remove the inner rails from the rack rails, attach the inner rails to the Device Expansion Unit

with a M4 Millimeter Screws.

Two round stamps
(located at 5U position)

Outer rail

Inner rail

Rack rail

(6) Install another outer rail on the rack in the same way as described in steps 1 to 4 above. 