Chapter 1  General Description 
 
Chapter 2  Preparations 
 
Chapter 3  Setup 
 
Chapter 4  Appendix 

10.201.32-101.01

July 2020

© NEC Corporation 2020

Содержание N8100-2836F

Страница 1: ...erver Express5800 Series Express5800 R120h 2M 3rd Gen EXP805 N8100 2836F 2837F 2838F 2839F Chapter 1 General Description Chapter 2 Preparations Chapter 3 Setup Chapter 4 Appendix 10 201 32 101 01 July...

Страница 2: ...f additional options connection of peripheral devices and suitable location for this server Chapter 3 Setup System utility configurations and summary of EXPRESSBUILDER Chapter 4 Appendix Specification...

Страница 3: ...oper operations 16 Chapter 1 General Description 18 1 Introduction 19 2 Accessories 20 3 Features 21 4 Names and Functions of Parts 25 4 1 Front View With Front Bezel 25 4 2 Front View Without Front B...

Страница 4: ...ink 70 Handling precautions 70 Installation 70 Identifying processor type 74 Removal 74 1 11 DIMM 75 Maximum supported memory size 75 DIMM installation order 76 Memory processor compatibility informat...

Страница 5: ...er Drive Cage N8154 98 164 Installing the Tertiary Riser Drive Cage N8154 95 167 Removal 171 1 28 3x 3 5 inch Rear Drive Cage N8154 99 172 Installation 172 Removal 174 1 29 4x 3 5 inch Mid plane Drive...

Страница 6: ...Items and Key Usage 235 2 4 Cases that Require Configuration 239 2 5 Management of RBSU Settings of System Utilities via Networks 243 Overview 243 How to Backup RBSU 244 How to Restore RBSU 245 Notes...

Страница 7: ...s symbol indicates the presence of a hazard if the instruction is ignored An image in the symbol illustrates the hazard type Prohibited Action This symbol indicates prohibited actions An image in the...

Страница 8: ...is server Optical disk drive This server is equipped with one of the following drives These drives are referred to as optical disk drive in this document DVD ROM drive DVD Super MULTI drive Hard disk...

Страница 9: ...7 Server Red Hat Enterprise Linux 7 Server x86_64 Abbreviations of Operating Systems VMware VMware Operating Systems are referred to as follows Notations in this document Official names of VMware ESXi...

Страница 10: ...Intel Corporation of the United States Linux is a trademark or registered trademark of Linus Torvalds in Japan and other countries Red Hat and Red Hat Enterprise Linux are trademarks or registered tr...

Страница 11: ...NESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BU...

Страница 12: ...nd or the Unified Extensible Firmware Interface UEFI Forum s UEFI Specifications v 2 0 and later together the UEFI Specifications only as necessary to emulate an implementation of the UEFI Specificati...

Страница 13: ...roduct includes software developed by Greg Roelofs and contributors for the book PNG The Definitive Guide published by O Reilly and Associates zlib End User License Agreement zlib License zlib h inter...

Страница 14: ...es no responsibility for effects resulting from your operations The sample values used in this document are not actual values Keep this document for future use Latest editions This document was create...

Страница 15: ...arning label Warning label are attached on or near the components with potential hazards This label is either attached or printed on the component Do not remove or black out this label and keep it cle...

Страница 16: ...disconnect the power cord before POST completes Turn off the server and unplug the power cord before moving it Regularly clean the server to prevent various types of failure See Chapter 1 Maintenance...

Страница 17: ...screen from reflecting bright lights and to make the display contents easy to see Working without adjusting the display to a comfortable angle makes it difficult for you to maintain a proper posture a...

Страница 18: ...This chapter introduces the features of this server and the name of each part 1 Introduction 2 Accessories Describes the accessories of the server 3 Features Describes the features of the server and t...

Страница 19: ...y the latest microprocessor Intel Xeon processor With our latest technology and architecture we offer high performance and high reliability that could not be accomplished by conventional servers Furth...

Страница 20: ...hed to Front Bezel Safety Precautions and Regulatory Notices Getting Started In addition to these enclosed items the following extra items may be required Operating system or application software Hard...

Страница 21: ...DP 125W DDR4 2933 1TB Xeon Gold 6230 Processor 2 10 GHz 20C 40T TDP 125W DDR4 2933 1TB Xeon Gold 6234 Processor 3 30 GHz 8C 16T TDP 130W DDR4 2933 1TB Xeon Gold 6238 Processor 2 10GHz 22C 44T TDP 140W...

Страница 22: ...essor 3 10GHz 20C 40T TDP 205W DDR4 2933 1TB Xeon Gold 6246R Processor 3 40GHz 16C 32T TDP 205W DDR4 2933 1TB Xeon Gold 6248R Processor 3 00GHz 24C 48T TDP 205W DDR4 2933 1TB Xeon Gold 6256 Processor...

Страница 23: ...configuration Silent sound design Enhanced Intel SpeedStep Technology supported Expandability Various option slots PCI Express 3 0 x16 lanes 5 slot Full height 7 PCI Express 3 0 x8 lanes 8 slots Full...

Страница 24: ...ies is not supported 5 Operating frequency can vary depending on the type or the number of boards of processor or memory installed 6 Power supply unit N8181 161 acquired 80 PLUS Titanium Power supply...

Страница 25: ...Names and Functions of Parts This section describes the names of the server parts 4 1 Front View With Front Bezel 1 Front Bezel A cover for protecting the front of the server This cover can be locked...

Страница 26: ...2 5 inch drive model Universal media bay 24 x 2 5 inch drive model 8 x 3 5 inch drive model 1 3 4 1 9 2 2 2 1 2 3 2 7 2 5 2 4 2 6 2 8 5 6 7 8 3 4 9 2 18 2 17 2 19 2 23 2 21 2 20 2 22 2 24 5 6 7 8 2 1...

Страница 27: ...remote management of iLO or firmware update the UID LED lights up or flashes if iLO is restarted via UID switch 7 iLO service port USB connector A USB connector used for connecting to iLO such as for...

Страница 28: ...arranged 8 USB 3 0 Connectors Connectors for connecting USB 3 0 interface devices 9 LINK LED LEDs for showing the status of LAN See page 41 10 ACT LED LEDs for showing the transfer speed of LAN ports...

Страница 29: ...4 Names and Functions of Parts Express5800 R120h 2M 3rd Gen User s Guide 29 Chapter 1 General Description 4 4 External View 1 Top cover 2 Hood latch 1 2...

Страница 30: ...d under the heat sink 1 CPU1 required option 2 CPU2 option 4 DIMM option 5 Slot for RAID Controller 6 Motherboard 7 Primary Riser Card Standard riser is standard installed Changeable by option 8 Secon...

Страница 31: ...or for optical disk drive 12 Power supply SW USB 3 0 connector 13 Battery connector for RAID controller 14 Power Connector for Expander Board 15 Power Connector for Expander Board 16 Power connector f...

Страница 32: ...f Reserved Important Do not change the system maintenance switch that says Reserved unless it is instructed by the document It may cause the trouble or malfunction of the device 1 Set the SW1 to ON wh...

Страница 33: ...recommended to let is operate without the necessary fans installed and running The following displays the structure for installing cooling fans Configuration Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 F...

Страница 34: ...fan setting to Increased Cooling in System Utilities Maintenance Guide Common Chapter 1 Useful Features 1 System Utilities 1 2 2 BIOS Platform Configuration RBSU 12 Advanced Options Menu a Fan and The...

Страница 35: ...ng Lights off The network is not working 4 UID switch LED 1 Do not reboot the iLO from the boot of the server until the completion of the OS boot and during using the System Utilities Lights in blue W...

Страница 36: ...s not working 4 UID Switch LED 1 Do not reboot the iLO from the boot of the server until the completion of the OS boot and during using the System Utilities Lights in blue Working in operation Flashes...

Страница 37: ...ng Lights off The network is not working 3 STATUS LED 1 Lights in green Normal state Flashes in green once per second Restarting iLO Flashes in amber The function of the system is deteriorating 3 Flas...

Страница 38: ...LED The following table shows a list on power failure LEDs and affected subsystems Not all power failures are applied on all servers Subsystem LED status Motherboard Flashes once Processor Flashes tw...

Страница 39: ...Lights off Normal state Lights in amber The power subsystem is degraded the power supply unit has failed or the input power is disconnected Riser Card LED Lights off Normal state Amber Riser card unit...

Страница 40: ...r card unit is not properly installed Cooling Fan LED Amber Amber Green One cooling fan has failed or has been removed Amber Red Green Two or more cooling fans have failed or have been removed Power S...

Страница 41: ...ights in green Working in operation Flashes in green Working in operation Lights off Not working 4 left AC POWER2 LED Lights in green Normal state Lights off One or more of the following situations ar...

Страница 42: ...US LED Lights in green A drive is a member of one or more logical drives Flashes in green Rebuilding the drive migrating RAID on the drive migrating or expanding the capacity of the strip size expandi...

Страница 43: ...0 R120h 2M 3rd Gen User s Guide 43 Chapter 1 General Description Optical Disk Drive Access LED optional The LED for optical disk drive at the front of the server flashes when a CD or DVD is being acce...

Страница 44: ...h 2M 3rd Gen User s Guide 44 Chapter 1 General Description 4 9 Identification of Drive Boxes Front BOX Chart number BOX number 1 BOX1 2 BOX2 3 BOX3 Chart number BOX number 1 BOX1 2 BOX2 3 BOX3 Rear BO...

Страница 45: ...4 Names and Functions of Parts Express5800 R120h 2M 3rd Gen User s Guide 45 Chapter 1 General Description Chart number BOX number 1 BOX4 2 BOX6 Mid BOX Chart number BOX number 1 BOX7...

Страница 46: ...er Controller Connection to a on board SATA port Connection to a PCI board AROC Type a to be installed on a dedicated connector for RAID controller Connection to a RAID controller PCI board Type p to...

Страница 47: ...4 Names and Functions of Parts Express5800 R120h 2M 3rd Gen User s Guide 47 Chapter 1 General Description Front Mid...

Страница 48: ...number 5 8 SAS Expander Port 5 connection Drive bay number 9 12 SAS Expander Port 6 connection Drive bay number 13 16 SAS Expander Port 7 connection Drive bay number 17 20 SAS Expander Port 8 connect...

Страница 49: ...nctions of Parts Express5800 R120h 2M 3rd Gen User s Guide 49 Chapter 1 General Description In the case of 12x 3 5 inch drive middle 4x 3 5 inch drive rear 2x2 5 inch drive cages x3 Mid Rear 2 5 inch...

Страница 50: ...eparations This chapter describes preparations for using this server 1 Installing Internal Optional Devices You can skip this section if you did not purchase any optional devices 2 Installation and Co...

Страница 51: ...and safely WARNING Be sure to observe the following precautions to use the server safety Failure to observe the precautions may cause death or serious injury For details see Safety Precautions and Re...

Страница 52: ...nents Beware of high temperatures Do not get your fingers caught when installing components If the server is mounted on a rack use the UID switch to identify the target server See Chapter 2 1 3 Identi...

Страница 53: ...k Drives in the RAID System Attach the air baffle See Chapter 2 1 33 Attaching the air baffle Attach Top Cover See Chapter 2 1 34 Installing Top Cover Mount the server onto the rack See Chapter 2 2 1...

Страница 54: ...When the server is working be sure to identify the target server by using UID Switch first before you turn off the server or disconnect a cable from the server To turn UID LED on press UID Switch When...

Страница 55: ...he right and unlock the lever seen on the left when you face the front bezel and pull only the left side of bezel by about 10 cm toward you Then as shown in the diagram pull the bezel to the left forw...

Страница 56: ...hexalobular driver T 10 or flathead driver See steps 1 to 5 in Chapter 2 1 2 Overview of Installation and Removal for preparations Unscrew the security screw with the hexalobular driver or flathead dr...

Страница 57: ...hs of time with the top cover air baffle expansion slot cover or the blank cover removed If the server operates under these conditions it will not be properly ventilated and the cooling mechanism will...

Страница 58: ...ed the TPM is bound to the Motherboard If an OS is configured to use the TPM and it is removed the OS may go into recovery mode data loss can occur or both When installing or replacing hardware our se...

Страница 59: ...shut off system power Portions of the power supply and some internal circuitry remain active until AC power is removed Important To reduce the risk of personal injury from hot surfaces allow the drive...

Страница 60: ...ent device the data including the key stored in TPM are deleted when the power is turned on The TPM that has been removed from the original server and installed on another server 5 Installing the TPM...

Страница 61: ...The recovery key password is generated during BitLocker setup and can be saved and printed after BitLocker is enabled When using BitLocker always retain the recovery key password The recovery key pas...

Страница 62: ...umber Important To avoid static electricity see Chapter 1 1 8 Anti static Measures in Safety Precautions and Regulatory Notices Make sure to use the CPU authorized by NEC Installing a third party CPU...

Страница 63: ...ESXi 6 7 768 112 1 When Hyper V is used the maximum number of logical processors is as shown below Windows Server 2012 R2 320 Windows Server 2016 512 Windows Server 2019 512 Installation Please prepar...

Страница 64: ...hten each heatsink nut in the order indicated on the heatsink label 1 2 3 4 until it no longer turns 4 If installing a second processor install fans in bays 1 and 2 These fans are provided with the pr...

Страница 65: ...6 Install an additional fan unit provided with additional CPU kit Remove the fan blank cover from the fan bay 7 Attach the fan to bay 1 and 2 Fan connection conditions are shown in the table below Fan...

Страница 66: ...on the POST To view this information and additional processor specifications follow the directions below 1 Reboot the server The server restarts and the POST screen is displayed 2 Press F9 key System...

Страница 67: ...server operate for extended lengths of time with the top cover open or removed When operating under these conditions poorly controlled airflow and cooling will make it to overheat and cause damage No...

Страница 68: ...tach the top cover of the server Note In order to prevent damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any o...

Страница 69: ...required for redundancy If the cooling fan fails or lacks the redundancy will fail High performance fans may be necessary in 8 x 2 5 inch configuration and 8 x 3 5 inch configuration for the following...

Страница 70: ...lling the option Parts included in the optional processor heat sink kit T 30 hexalobular driver 1 4 flat blade screwdriver or nonconductive tool To install the components follow these steps 1 Please f...

Страница 71: ...processor socket contact 3 Lift the processor heat sink module up and remove 4 Turn over the heat sink module and position the contact surface of the processor at the top 5 Install the protective cove...

Страница 72: ...ch the point of contact of the processor 7 Remove the dust cover of the high performance heat sink 8 Align the pin mark 1 on the processor frame with the pin mark 1 on the high performance heat sink g...

Страница 73: ...e to tighten each heatsink nut fully in the order indicated Otherwise boot failure or intermittent shutdowns might occur 11 Make sure that the heat sink is installed on a level with the motherboard No...

Страница 74: ...ed simply on the POST To view this information and additional processor specifications follow the directions below 1 Reboot the server The server restarts and the POST screen is displayed 2 Press F9 k...

Страница 75: ...information corresponding to all the types all the types are referred to as DIMM If you specify LRDIMM or RDIMM the information is applicable only to the type It is necessary that the type of all of...

Страница 76: ...2 CPU PROC1 PROC2 configuration When only CPU1 is mounted DIMM slot number 1 2 3 4 5 6 7 8 9 10 11 12 DIMM Mounted number and installation 1 DIMM 1 2 DIMM 1 2 3 DIMM 1 2 3 4 DIMM 4 3 1 2 5 DIMM 5 4 1...

Страница 77: ...2 10 22 8 20 14 2 16 4 18 6 11 9 21 7 19 13 1 15 3 17 5 23 DIMM 12 10 22 8 20 14 2 16 4 18 6 11 23 9 21 7 19 13 1 15 3 17 5 24 DIMM 12 24 10 22 8 20 14 2 16 4 18 6 11 23 9 21 7 19 13 1 15 3 17 5 Impor...

Страница 78: ...nel processor model and speed selected on System Utility The maximum memory capacity Maximum memory capacity depends on DIMM capacity the number of installed DIMM memory type and the number of process...

Страница 79: ...ion against uncorrectable memory errors than provided by Advanced ECC The Memory Mirroring function and Memory Sparing function create redundancy by monitoring and switching memory between memory chan...

Страница 80: ...1 Installing Internal Optional Devices Express5800 R120h 2M 3rd Gen User s Guide 80 Chapter 2 Preparations Memory Controller 1 Memory Controller 2 Memory Controller 1 Memory Controller 2 PROC1 PROC2...

Страница 81: ...Maintenance Guide Common Important Single rank DIMMs do not support the Memory Mirroring function The followings are the conditions to use this function Install 12 DIMMs per CPU Use DIMMs with the sam...

Страница 82: ...sor Notes for the setting of memory mirroring Even if Mirrored Memory with Advanced ECC Support is set in Advanced Memory Protection and Memory Mirroring Configuration is selected in case DIMM configu...

Страница 83: ...led is recognized it changes depending on the number of DIMM installed and the capacity per one For the physical memory capacity available from the operating system refer to the table below The number...

Страница 84: ...cted Mounting DIMMs with different product numbers on the spare set Memory sparing between different memory channels Note When using Memory Mirroring Function install 12 DIMMs per CPU Use memories wit...

Страница 85: ...DDC as long as it is available in the configuration Note Mount the memory so that the total number of RANK for each channel is 2 or higher This restriction will be removed in System ROM v2 10 or later...

Страница 86: ...tion Meaning 1 Capacity 8GB 16GB 32GB 64GB 128GB 2 Rank 1R Single rank 2R Dual rank 4R Quad rank 8R Octal rank 3 DRAM data width X4 4 bit X8 8 bit X16 16 bit 4 Memory generation DDR4 5 The maximum spe...

Страница 87: ...ally closes Important Make sure the orientation of the DIMM The DIMM has a notch preventing being incorrectly inserted Do not apply too much pressure when you push a DIMM into the slot Doing so can da...

Страница 88: ...he trouble shooting on a malfunctioning DIMM or the information on LEDs see 4 Status LED Panel combined LED descriptions Removal Replacement To replace or remove DIMM follow these steps To remove DIMM...

Страница 89: ...ure below For details see Chapter 1 1 8 Anti static Measures in Safety Precautions and Regulatory Notices Notes Read the following notes when installing or removing a riser card Do not touch the termi...

Страница 90: ...length Full height HL FH PCIe3 x16 16 8 4 2 1 6 3 Half length Full height HL FH PCIe3 x8 8 4 2 1 Riser Card 2xPCI N8116 64 No Slot PCIe type Description 1 Power cable connector for back up 2 1 Full l...

Страница 91: ...ndary Riser Card Riser Card 3xPCI N8116 62 No Slot PCIe type Description 1 GPU Power cable connector 2 Power cable connector for back up 3 4 Full length Full height FL FH PCIe3 x8 8 4 2 1 4 5 Half len...

Страница 92: ...on 1 GPU Power cable connector 2 Power cable connector for back up 3 5 Half length Full height HL FH PCIe3 x16 16 8 4 2 1 4 6 Half length Full height HL FH PCIe3 x16 16 8 4 2 1 Rear 2 5 Drive cage 1xP...

Страница 93: ...6 78 No Slot PCIe type Description 1 7 Full length Full height FL FH PCIe3 x16 16 8 4 2 1 2 Power cable connector for back up 3 GPU Power cable connector Riser Card 2xPCI N8116 81 No Slot PCIe type De...

Страница 94: ...handles located on the upper part of the riser card and turn it 180 to the left Then pull the riser card up to remove it 3 Adjust the position of the riser card edge of the riser card to the position...

Страница 95: ...move all the AC power cables before removing installing riser card To install the components follow these steps 1 See steps 1 to 6 in Chapter 2 1 2 Overview of Installation and Removal for preparation...

Страница 96: ...the power supply ON Installing Tertiary Riser Card Please prepare the following before installing the options Parts included in the option kit T 10 hexalobular driver Note In order to prevent the dama...

Страница 97: ...tiary riser card butterfly riser card and fasten with 3 screws After that proceed to step 6 5 Remove the 2 screws that fix the secondary riser blank cover in place and remove the cover by lifting it u...

Страница 98: ...card in place Then return the screw handles to their original positions 9 See Chapter 2 1 34 Installing Top Cover to attach the top cover of the server Note In order to prevent damage of the system du...

Страница 99: ...Please prepare the following before installing the options Parts included in the option kit M 2 media If expanding Phillips screwdriver To install the components follow these steps 1 See steps 1 to 6...

Страница 100: ...ing the riser card put down the screw handles as before 6 See Chapter 2 1 34 Installing Top Cover to attach the top cover of the server Note In order to prevent damage of the system due to improper co...

Страница 101: ...ion board please remove all the AC power cables before removing installing riser card All slots support full height PCI cards Use the PCI card length according to the table below Primary riser connect...

Страница 102: ...HL FL FL HL HL HL HL FL FL HL N8103 189 RAID Controller 0MB RAID 0 1 PCI Express 3 0 x8 N8103 190 RAID Controller 2GB RAID 0 1 5 6 PCI Express 3 0 x8 Maximum of up to 1 Flash Backup Unit per device N8...

Страница 103: ...ot be used N8104 181 Quad Port 1000BASE T Adapter PCI Express 2 0 x4 1 3 5 2 4 6 7 8 Network cables with RJ 45 plug covers cannot be used N8104 178 Dual Port 1000BASE T Adapter PCI Express 2 0 x1 1 3...

Страница 104: ...ce 1 Slot form 2 Slot size Slot performa nce 1 Slot form 2 Slot size M 2 SATA SSD slot GPU power connector N8116 56 x16 x16 FH FL x16 x16 FH HL N8116 62 x8 x8 FH FL x16 x16 FH HL x8 x8 FH HL Supported...

Страница 105: ...completely by the power button on the front panel Until the AC power cord is unplugged the power supply circuit is still active in some parts of the machine Note When running a server always ensure p...

Страница 106: ...lectric parts installed on the board Installing boards with dirt or oil can cause malfunction Note Make sure that the edge of a PCI card bracket is seated into the fixed slot of the riser card unit De...

Страница 107: ...right 180 degrees to fix the cage Then put down the screw handle as before 7 See Chapter 2 1 34 Installing Top Cover to attach the top cover of the server Note In order to prevent damage of the system...

Страница 108: ...ver baffle expansion slot cover and blank If the server supports components with hot plug support minimize the amount of time the top cover is open Please prepare the following before installing the o...

Страница 109: ...t 7 Fit the terminal of riser card to the slot on the mother board and insert the terminal firmly into the slot Then fix the riser card Next raise the screw handle at the top of cage and turn the hand...

Страница 110: ...wire treatment is not conducted Installing RAID Controller Please prepare the following before installing the option Parts included in the option kit To install the components follow these steps 1 Mak...

Страница 111: ...ser card to direction 1 and remove the blank cover by pulling it out to direction 2 Note Keep each removed blank covers 5 Fit properly the terminal parts of PCI board to the connector of riser card an...

Страница 112: ...to the slot on the mother board and insert the terminal firmly into the slot Then fix the riser card Next raise the screw handle at the top of cage and turn the handle to the right 180 degrees to fix...

Страница 113: ...improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bays 11 Please see Chapter 2 2 In...

Страница 114: ...ssibility of causing electrostatic discharge if appropriate grounding wire treatment is not conducted Installation Please prepare the following before installing the option Parts included in the optio...

Страница 115: ...ling Top Cover to attach the top cover of the server Note In order to prevent damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure withou...

Страница 116: ...9803 001 X4 Mini SAS cable Port 1 Port 1 Group B From SAS Expander to front 2 5 inch drive cage Cable Description Connection to SAS Expander Connection to Drive BOX 776402 001 X4 Mini SAS cable Port 3...

Страница 117: ...the options Parts included in the option kit To install the components follow these steps 1 See steps 1 to 7 in Chapter 2 1 2 Overview of Installation and Removal for preparations 2 Remove the fan cag...

Страница 118: ...he cover to direction 2 Then remove the blank cover of Slot 3 Note Keep each removed blank covers 5 Properly insert the SAS Expander Card port component into the riser card connector and close it by s...

Страница 119: ...y into the slot Then fix the riser card Next raise the screw handle at the top of cage and turn the handle to the right 180 degrees to fix the cage Then put down the screw handle as before 7 Confirm i...

Страница 120: ...onnecting the PCI board Type p exclusively for the RAID controller and the SAS expander 8 Connect the SAS expander and the backplanes of the various drive cages Connecting the backplane of the 2 5 inc...

Страница 121: ...Chapter 2 Preparations Connecting the backplane of the 2 5 inch drive BOX 1 BOX 2 BOX 3 and the SAS expander Connecting the backplane of the rear primary 2 5 inch drive cage and the SAS expander Conn...

Страница 122: ...e 122 Chapter 2 Preparations Connecting the backplane of the rear tertiary 2 5 inch drive cage and the SAS expander Connecting the backplane of the rear 3x3 5 inch drive cage and the SAS expander Conn...

Страница 123: ...rations 9 Remove all the fans from the fan cage to the state where only the fan cage is left Next align the fan cage with the device push the cage slowly from the above direction and tilt both sides o...

Страница 124: ...damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bays...

Страница 125: ...d depending on the number of installed GPUs 3 Options with restrictions on mounting CPU The following CPUs cannot be mounted Platinum 8280 8280M 8280L 8268 8260 8260M Gold 6254 No restriction Internal...

Страница 126: ...units that can be mounted 8 or less Middle Rear Drive Cage Cannot be mounted PCI Board 4 No restriction Dustproof Filter Kit None Up to 3 Up to 1 Operation Temperature N8100 2836F 8x2 5 inch Drive Mod...

Страница 127: ...ir baffle The locations of primary secondary and tertiary are shown in the figure Attach the clip parts according to each configuration 4 Install the high performance heat sink See Chapter 2 1 10 High...

Страница 128: ...rts fixing the blank cover to direction 1 and remove the blank cover by pulling it out to direction 2 8 Align and insert the terminal part of the GPU board correctly into the connector of the riser ca...

Страница 129: ...e 13 See Chapter 2 1 34 Installing Top Cover to attach the top cover of the server Note In order to prevent damage of the system due to improper cooling or elevated temperature please do not activate...

Страница 130: ...1 1 8 Anti static Measures in Safety Precautions and Regulatory Notices Installation Please prepare the following before installing the option Parts included in the option kit T 10 hexalobular driver...

Страница 131: ...dles as before 7 See Chapter 2 1 34 Installing Top Cover to attach the top cover of the server Note In order to prevent damage of the system due to improper cooling or elevated temperature please do n...

Страница 132: ...Flash Backup Unit is an extremely sensitive device Prior to installation avoid static electricity by touching the metal frame of the unit or similar Do not drop or otherwise damage Flash Backup Unit F...

Страница 133: ...1 Installing Internal Optional Devices Express5800 R120h 2M 3rd Gen User s Guide 133 Chapter 2 Preparations 3 Remove the fan cage 4 Install Flash Backup Unit 5 Connect the cable...

Страница 134: ...rations 6 Remove all the fans from the fan cage to the state where only the fan cage is left Next align the fan cage with the device push the cage slowly from the above direction and tilt both sides o...

Страница 135: ...system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bays 11 Please see...

Страница 136: ...B Two microSDs able to install and boot VMware ESXi and USB conversion kit Notes N8106 016 2x8GB microSD card installing kit USB and N8106 020 2x32GB microSD card installing kit USB are equipped with...

Страница 137: ...Insert USB flash memory into the connector Removal When removing practice the steps of installing reversely When you operate the device without components install the blank cover that was installed on...

Страница 138: ...please start to install the system after conducting the appropriate anti static treatment There is a possibility of causing electrostatic discharge if appropriate grounding wire treatment is not condu...

Страница 139: ...es from the front and insert the universal media bay unit and fix it in place using the 2 screws 6 If installing the optional optical disk drive remove the optical disk drive blank cover The blank cov...

Страница 140: ...the front to the universal media bay and fix it in place with a screw 8 Connect cables Connect the Displayport cable to the Displayport connector Connect the USB cable to the front dual internal USB 3...

Страница 141: ...rations 9 Remove all the fans from the fan cage to the state where only the fan cage is left Next align the fan cage with the device push the cage slowly from the above direction and tilt both sides o...

Страница 142: ...t damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bay...

Страница 143: ...per earth is not provided electrostatic discharge may occur Before installing the option prepare the followings Parts included in the option kit T 10 hexalobular driver DVD ROM drive N8151 137 or DVD...

Страница 144: ...by pushing out the right end of it from the inside to the outside or pulling it out 7 Insert the optical disk drive from the front and fix it with a screw 8 Insert the module attached with the optical...

Страница 145: ...uide 145 Chapter 2 Preparations Connect the power switch module cable to the connector Connect Displayport cable to the connector Connect the optical disk drive cable to the connector SATA5 Power swit...

Страница 146: ...2 Preparations 10 Install the fan cage Remove all the fans from the fan cage and confirm no fan is installed in the cage Next fit the fan cage to the device push the cage slowly from above and lower...

Страница 147: ...improper cooling or an elevated temperature do not operate the server or the enclosure without installing any of component or blank on all the drive bays and device bays 13 Execute the installation an...

Страница 148: ...install the system after conducting the appropriate anti static treatment There is a possibility of causing electrostatic discharge if appropriate grounding wire treatment is not conducted Please prep...

Страница 149: ...er s Guide 149 Chapter 2 Preparations 3 Unfasten the screws x2 of the bay blank cover and pull the blank cover forward to remove it BOX2 Note Keep each removed blank covers 4 Insert the 8x 2 5 inch dr...

Страница 150: ...press5800 R120h 2M 3rd Gen User s Guide 150 Chapter 2 Preparations 5 Connect the power cable of 8x 2 5 inch drive cage BOX2 Single power cable 6 The drive bay data cables are connected as follows BOX2...

Страница 151: ...rations 7 Remove all the fans from the fan cage to the state where only the fan cage is left Next align the fan cage with the device push the cage slowly from the above direction and tilt both sides o...

Страница 152: ...damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bays...

Страница 153: ...s a possibility of causing electrostatic discharge if appropriate grounding wire treatment is not conducted Please prepare the following before installing the options Parts included in the option kit...

Страница 154: ...k cover and remove the cover pulling it out forward Note Keep each removed blank covers 5 Unfasten the screws x3 securing the optical disk drive tray and draw out and remove the tray from the back of...

Страница 155: ...ach the 2x 2 5 inch drive bay to the universal media bay and secure it with the screws x4 8 Insert and attach the optical disc drive tray in the universal media bay from behind and secure it with the...

Страница 156: ...156 Chapter 2 Preparations 10 Connect the drive bay power cable to the power connector on the motherboard 11 Connect the drive bay data cables to the inputs below Connecting to the SAS expander for th...

Страница 157: ...ations 12 Remove all the fans from the fan cage to the state where only the fan cage is left Next align the fan cage with the device push the cage slowly from the above direction and tilt both sides o...

Страница 158: ...t damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bay...

Страница 159: ...parts start the installation of system after providing proper anti static treatment If a proper earth is not provided electrostatic discharge may occur Before installing the option prepare the followi...

Страница 160: ...ard you to dismantle it 5 Insert a front 2x 2 5 inch drive cage N8154 96 or N8118 317 from the front and fix them with two screws 6 Connect the power cable of a front 2x 2 5 inch drive cage N8154 96 o...

Страница 161: ...ting to SAS SATA drive cage N8154 96 and RAID controller Connecting to SAS SATA drive cage N8154 96 and SAS expander 8 Remove all the fans from the fan cage and confirm no fan is installed in the cage...

Страница 162: ...1 Installing Internal Optional Devices Express5800 R120h 2M 3rd Gen User s Guide 162 Chapter 2 Preparations 9 Push the fan from above to mount it on the fan cage 10 Reinstall all the fans you removed...

Страница 163: ...he drive bays and device bays 13 Execute the installation and connection referring to Chapter 2 2 Installation and Connection of this book and then turn the power on Removal When removing practice the...

Страница 164: ...nt damage unplug the power cord and ensure no power is supplied to the server You cannot turn off the system power supply completely by the power button on the front panel Until the AC power cord is u...

Страница 165: ...Raise the screw handles at the top of the primary riser card and turn them to the left 180 degrees Then hold both sides of cage and lift them upright to remove the cage 4 In case of secondary riser un...

Страница 166: ...nto the slot Then fix the riser card Next raise the screw handle at the top of the cage and turn the handle to the right 180 degrees to fix the cage Then put down the screw handle as before 7 Connect...

Страница 167: ...he Tertiary Riser Drive Cage N8154 95 Important To prevent personal injury electrical shock or equipment damage unplug the power cord and ensure no power is supplied to the server You cannot turn off...

Страница 168: ...raise the screw handle at the top of the riser card turn it 180 degrees to the left hold the both ends of the cage and lift it straight up to remove it 3 Unfasten the screws x3 securing the tertiary b...

Страница 169: ...ews x4 6 Attach a drive or a dummy tray to the drive cage 7 If you removed a riser card in the step2 fit the terminal of riser card to the slot on the mother board and insert the terminal firmly into...

Страница 170: ...d Gen User s Guide 170 Chapter 2 Preparations 8 Connect the power cord between drive backplane and motherboard In case of 12x 3 5 inch drive configuration and power single cable connection In case of...

Страница 171: ...der to prevent damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays a...

Страница 172: ...lling this option the 12x 3 5 inch drive must be fully installed in the front bay In addition a high performance fan should be installed To install the components follow these steps 1 Back up all data...

Страница 173: ...e screws x3 securing the tertiary riser blank cover and pull the cover upward to remove it 5 Attach a rubber bush on a slotted hole on the bottom of the 3 x 3 5 drive cage install the cage from the to...

Страница 174: ...ystem due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bays 10 Please see C...

Страница 175: ...re installing the options Parts included in the option kit The option must be attached under the following conditions A 1U heat sink is required to attach this option Attach the 1U heat sink before at...

Страница 176: ...he motherboard 4 Lift up the latch of the drive cage 5 Install the drive cage Note Do not drop the drive cage onto the motherboard Dropping the drive cage onto the motherboard may damage the motherboa...

Страница 177: ...e plunger pin on the back right of the mid plane drive cage and slowly lower the mid plane drive cage until it interlocks with the plunger pin The mid plane drive cage is attached in this manner 6 Mou...

Страница 178: ...erver Note In order to prevent damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all...

Страница 179: ...ponents please start to install the system after conducting the appropriate anti static treatment There is a possibility of causing electrostatic discharge if appropriate grounding wire treatment is n...

Страница 180: ...s connected to the cable and pull the module towards you to remove it Do not lose the T 10 screw as it necessary for attachment 4 Route the cables through the openings on the front side of the server...

Страница 181: ...rations 6 Remove all the fans from the fan cage to the state where only the fan cage is left Next align the fan cage with the device push the cage slowly from the above direction and tilt both sides o...

Страница 182: ...damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and device bays...

Страница 183: ...install the system after conducting the appropriate anti static treatment There is a possibility of causing electrostatic discharge if appropriate grounding wire treatment is not conducted Installati...

Страница 184: ...ial blank cover as shown below 3 Install the serial cable A If a tertiary riser is not attached 1 Position the serial cable as shown below 2 Attach the serial cable connector 3 Secure the external con...

Страница 185: ...prevent damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of component or blank on all of drive bays and dev...

Страница 186: ...hen building a RAID System The number of hard disk drives required varies in each RAID level If the optional RAID Controller N8103 189 195 is used the RAID System cannot be built in RAID5 RAID6 RAID50...

Страница 187: ...pter 2 Preparations 1 33 Attaching the air baffle The procedure for removal is the reverse of installation Important Keep the air baffle close to the device when attaching it so the cables are not pul...

Страница 188: ...thead driver Leave the hood latch open and place the top cover straight on the unit so that it is securely inserted in the frame Adjust the position of the top cover so that it protrudes approximately...

Страница 189: ...isk drives of different types and or rotational frequencies cannot be used together When performing RAID constructions use hard disk drives of the same capacity type and rotational frequency within th...

Страница 190: ...ve model SAS SATA HDD 8x 3 5 inch drive model SAS SATA HDD 2x2 5 SAS SATA HDD SSD PCIeSSD 12x 3 5 inch drive model SAS SATA HDD 4x 3 5 SAS SATA HDD 3 5 inch drive model rear 2x2 5 SAS SATA HDD SSD 3x3...

Страница 191: ...SSD 24x2 5 inch drive model rear 2x2 5 SAS SATA HDD SSD 12x 3 5 inch drive model SAS SATA HDD 12 x 3 5 inch drive model Mid plane Drive SAS SATA HDD 12x 3 5 inch drive model rear SAS SATA HDD SAS Exp...

Страница 192: ...each Disk Array 1 See Chapter 2 1 2 Overview of Installation and Removal for preparations Locate the slot where you install the hard disk drive Install hard disk drives in ascending order of port numb...

Страница 193: ...d blank should be installed for server operation If the server supports the hot pluggable components please minimize the opening time of the top cover 1 Check the drive status via definition of the dr...

Страница 194: ...same capacity Make sure that the two power supply units have the same part number and the same label color If the two power supply units are inappropriate the system may become unstable to be shut dow...

Страница 195: ...power cords When the power cord is connected the AC power LED on the power unit will turn green Power on the server Confirm by STATUS LED or on POST screen that there are no errors related to the pow...

Страница 196: ...e the LED AC power LED is off Power off the server Tips In the redundant power configuration with two power supply units and if either one of power supply units fails the failing power supply unit can...

Страница 197: ...ecome unstable to be shut down Note In order to prevent damage of the system due to improper cooling or elevated temperature please do not activate the server or enclosure without implementing any of...

Страница 198: ...tional Devices Express5800 R120h 2M 3rd Gen User s Guide 198 Chapter 2 Preparations 3 Remove the screw and remove the ground wire terminal 4 Attach the ground wire green to the terminal 5 Remove the t...

Страница 199: ...crews on the terminal block connector 7 Connect the ground wire attached to the contact in Step 4 to the power supply unit DC with the screw as shown below Important Make sure to connect it before con...

Страница 200: ...Similarly insert the return line DC into the right slot of the terminal block connector and tighten the screw 10 After inserting the 2 lines to the terminal block connector connect it to the power su...

Страница 201: ...unit DC illuminate Express5800 R120h 2M Rear side 15 Power on the server 16 Confirm by STATUS LED or on POST screen that there are no errors related to the power supply units See Chapter 2 1 IML Error...

Страница 202: ...the front view of the front bezel into a recess on the front part of the device push the left side lever to the right set in place the left side of the device and then release the lever so that it wi...

Страница 203: ...n the specified environment Do not connect the ground wire to a gas pipe CAUTION Be sure to observe the following precautions to use the server safely Failure to observe the precautions may cause burn...

Страница 204: ...the outlet of another device with large power consumption Place near equipment that generates power noise e g contact spark at power on power off of commercial power supply through a relay Environment...

Страница 205: ...that the manufacturer s TMRA specification is not exceeded Power requirements The installation of this equipment must be performed by a qualified electrician according to the electrical standards of...

Страница 206: ...NEC and IEC 60950 1 Second edition The standard for Safety of Information Technology Equipment Connect the equipment to the secondary circuit power supply that is properly grounded The secondary circ...

Страница 207: ...ool to attach the ring tongue to the power cord wire Important The ring terminal must conform to UL certified 12 gauge Important The minimum nominal diameter for the sled of pillar or stud type termin...

Страница 208: ...ecautions to use the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety Precautions and Regulatory Notices Do not drop Do not leave...

Страница 209: ...nch drive model N8143 130 Slide Rail Kit for 2U 3 5inch Server Ball bearing type rack rail for 3 5 inch drive model no inner rail used N8143 134 Tool free Slide Rail Kit for 2U 3 5inch Server Slide ra...

Страница 210: ...uter rail RIGHT to the right Slide the inner rail to the rear side of the unit in accordance with the four protrusions on the side of the unit At this time check whether the lock located around the ce...

Страница 211: ...he same way Make sure that the rail is installed at the same height as the other rail already installed Important Confirm that the rail are securely locked so that they will not fall off Tips Although...

Страница 212: ...e outer rails Check the direction of the outer rail Since there are markings of Right and Left on the outer rail check the proper directions of right and left with it Likewise check the directions of...

Страница 213: ...tant Confirm that the rail are securely locked so that they will not fall off Tips Although the rail may be somewhat unsteady it is not defective Removing the outer rails Remove outer rails from the r...

Страница 214: ...n Express5800 R120h 2M 3rd Gen User s Guide 214 Chapter 2 Preparations 4 Push and release the unlocking lever on the rear side of the outer rail toward the outside of the rack and push the rail backwa...

Страница 215: ...rver with single person Do not drop Do not leave the server being pulled out Do not install with the cover removed Do not get your fingers caught 1 Tool free Slide Rail Kit for 2U N8143 133 134 a Inst...

Страница 216: ...included cable tie strip to the rear side of the rack attach the tie strip to the mounting hole of the outer rail as shown below 4 If you like to secure the unit to the rack with screw open the lid of...

Страница 217: ...Remove the front bezel Open the lids of the unit fixing screws on both sides of the device Then remove the fixing screws inside with Hexalobular screwdriver if the device is screwed on If the device...

Страница 218: ...re Important Always install the server with two or more persons 1 Pull out the left and right outer rails until they are completely locked to the front side 2 Hold the unit securely by two or more per...

Страница 219: ...secure the unit to the rack with screw open the lid of the edge part of the unit and fasten the Hexalobular screw inside with a Hexalobular screwdriver to secure the unit to the rack b Removal procedu...

Страница 220: ...220 Chapter 2 Preparations Open the lids of the unit fixing screws on both sides of the device Then remove the fixing screws inside with Hexalobular screwdriver if the device is screwed on If the dev...

Страница 221: ...the stopper button on the side of the rail and lift the device above the rails in the order of 1 2 3 4 to remove it from the rail Important Be careful not to get your fingers caught in the rails or le...

Страница 222: ...ause death or serious injury For details refer to Safety Precautions and Regulatory Notices Do not hold the power plug with wet hands Do not connect the ground wire to a gas pipe CAUTION Be sure to ob...

Страница 223: ...cannot be used to connect with leased line FRONT REAR Device with serial interface USB device Display unit Finally connect the provided power cord to an outlet For connecting with UPS refer to the nex...

Страница 224: ...with the UPS When the power cord is connected to a UPS change the settings from System Utility in order to link the server with the power supply from the UPS To change the settings select System Confi...

Страница 225: ...nagement arm A cable management arm can be installed to the unit for combining the multiple cables connected to the device Install the cable management arm in the following steps 1 Attach the power co...

Страница 226: ...Express5800 R120h 2M 3rd Gen User s Guide 226 Chapter 2 Preparations 3 Put multiple cables in the binding belt and secure them 4 Insert the fixed parts of the supplied cable management arm into the ou...

Страница 227: ...moving the cable management arm 1 Press the lock release button on the fixed part of the cable management arm to release the lock and pull it out forward 2 Press the lock release button on the two fix...

Страница 228: ...tion 2 Description on System Utility Describes how to set up the system 3 iLO 5 Describes iLO 5 installed in the unit 4 EXPRESSBUILDER and Starter Pack EXPRESSBUILDER helps you to install Windows and...

Страница 229: ...ptible power supply UPS make sure that the power supply control unit is turned ON Remove Front Bezel When the STATUS lamp flashes green once per second wait until the lamp lights in steady state Press...

Страница 230: ...1 Turning on the Server Express5800 R120h 2M 3rd Gen User s Guide 230 Chapter 3 Setup 8 x 3 5 inch drive model 12 x 3 5 inch drive model Power switch Power switch...

Страница 231: ...and an initialization message is displayed The message to tell initialization of a memory and a PCI device Note While the initialization messages are being displayed the screen may change several time...

Страница 232: ...attached to each option board Necessary key inputs are different depending on option boards installed so you are requested to operate according to messages 4 The OS starts when POST is completed Tips...

Страница 233: ...on Selection of Primary Boot Controller Configuration of Memory Option Selection of language Start of pre boot environment such as built in UEFI shell or EXPRESSBUILDER Regarding the details of System...

Страница 234: ...reboot the server To save your change in System Utility and exit press F12 Key F12 Save and Exit In case you cancel your change and exit press ESC Key Exit Tips To put the setting back to the default...

Страница 235: ...ntly selected key key Change the value parameter of the selected item You cannot use this key when a menu which has on the left is selected Enter key Press this key to determine the selected parameter...

Страница 236: ...ystem Utility Press Esc key to go back to the original screen F7 key The following screen is displayed To put the parameters of System Utility back to the default setting select Restore Defaults and R...

Страница 237: ...f System Utilities When saving settings after a setting change in BMC Configuration Utility of System Utilities a restart of iLO may be required In this case perform the following steps If you fail to...

Страница 238: ...lamp on the front of this product The STATUS lamp blinking in green once per second indicates that iLO is being restarted The STATUS lamp illuminating in green indicates that the restart of iLO is co...

Страница 239: ...n RBSU Workload Profile At the time of shipment Workload Profile is set to Custom Set to No C states at System Configuration BIOS Platform Configuration RBSU Power and Performance Options Minimum Proc...

Страница 240: ...he following OSs are applicable Red Hat Enterprise Linux 7 x86_64 Windows Server 2012 R2 Windows Server 2016 Windows Server 2019 VMware ESXi6 5 VMware ESXi6 7 The setting must be done in compliance wi...

Страница 241: ...Use Wake on LAN WOL Set Enabled Disabled in a and b below The setting of b is not reflected when Embedded LOM is used a System Configuration Network Device MBA Configuration Menu or NIC Configuration...

Страница 242: ...Power On in System Configuration BIOS Platform Configuration RBSU System Options Server Availability Automatic Power On To connect the UPS to the serial port set Disabled for the settings below 1 Set...

Страница 243: ...ned OFF While POST Immediately after POST Important The Serial Number and Product ID are device specific information Make a note of them and store it in a safe place Tips After completion of POST exec...

Страница 244: ...password which are required to log in are written on a slide tag attached to the controlled server 4 Execute types command and confirm the parameter on whose lead Bios is displayed 5 Select BIOS in s...

Страница 245: ...function of select command specify the parameter you confirmed in step 4 6 Execute load command to restore RBSU you backed up As the argument of select command specify the parameter you confirmed in s...

Страница 246: ...ID by referring to The server loses Serial Number and Product ID in 5 11 Problem of Others in 5 Troubleshooting in Chapter 1 of Maintenance Guide The following menus and menus under them cannot be bac...

Страница 247: ...lth System Log AHS Log Download Active Health System Log In case the support is needed AHS Log file may need to be sent to NEC or taken by maintenance staff iLO Cooperative Network Management By using...

Страница 248: ...only Pre OS only Global Team Collaboration by 6 server administrators at the maximum via IRC Recording and playback of video via IRC Recording and playback of Virtual Serial Port Remote Console of te...

Страница 249: ...wser Run POST following Chapter 3 1 1 1 POST sequence After a while the following message is displayed on the lower part of the screen Press the F9 key while the message is being displayed to launch S...

Страница 250: ...mple when Network Options is selected On the next screen use DHCP Set DHCP item to Enable or set the item under IP Address Subnet Mask Connect a LAN cable to a management specialized LAN connector to...

Страница 251: ...ion Change password without fail at the time of initial setup If you use the initial password unchanged and then you suffer unauthorized access we will not hold any responsibility at all Even if you c...

Страница 252: ...SPP automatically when installing OS SPP must be installed after installing OS Application installation Installs NEC ESMPRO RESTful Interface Tool and other applications Manuals Stores manuals for ap...

Страница 253: ...tware Components Express5800 R120h 2M 3rd Gen User s Guide 253 Chapter 3 Setup 5 Installing Software Components Continue to install software components such as OS See the instructions below Installati...

Страница 254: ...of the following methods Press and release the POWER switch This method shuts down applications and OS in the correct order before the server enters standby mode Press and hold the POWER switch for 4...

Страница 255: ...Express5800 R120h 2M 3rd Gen User s Guide 255 NEC Express5800 Series Express5800 R120h 2M Appendix 1 Specifications 2 Glossary 3 Revision Record...

Страница 256: ...uilt in 2 5 inch HDD SATA 48TB 24x 2TB SAS 57 6TB 24x 2 4TB 2 5 inch SSD SATA SSD 92 16TB 24x 3 84TB SAS SSD 23 04TB 24 960GB When an optional HDD cage is added 2 5 inch HDD SATA 60TB 30x 2TB SAS 72TB...

Страница 257: ...C Power Unit N8181 161 800W 80 PLUS Titanium power supply unit Outlet with two pole parallel earth Hot plug able Max 2 AC200 240V 10 50 60Hz 3Hz Power cable type needs to be selected AC Power Unit N81...

Страница 258: ...on Gold 6254 Processor 3 10GHz 18C 36T TDP 200W DDR4 2933 1TB Xeon Platinum 8260 Processor 2 40 GHz 24C 48T TDP 165W DDR4 2933 1TB Xeon Platinum 8268 Processor 2 90 GHz 24C 48T TDP 205W DDR4 2933 1TB...

Страница 259: ...ibed from T1 to T100 This is sometimes abbreviated as 6lobe iLO A built in controller that supports the IPMI version 2 0 protocol The controller is called as iLO5 because this server adopts a generati...

Страница 260: ...des SPP instruction manual application and other software for the server This must be installed before using OS on the server Starter Pack is provided as an optional product and ISO data on our websit...

Страница 261: ...3 Revision Record Express5800 R120h 2M 3rd Gen User s Guide 261 Chapter 4 Appendix 3 Revision Record Document Number Date Issued Description 10 201 32 101 01 July 2020 Newly created...

Страница 262: ...h 2M 3rd Gen User s Guide July 2020 NEC Corporation 7 1 Shiba 5 Chome Minato Ku Tokyo 108 8001 Japan NEC Corporation 2020 The contents of this manual may not be copied or altered without the prior wri...

Отзывы: