2-2
1. Application
This adjustment specification shall be applied to the adjustment of the LCD1550V (LA-15R02-1) /
LCD1550V-BK (LA-15R02-1-BK).
2. Adjustment conditions
2.1 Time for adjustment
Adjustment of a unit to be adjusted shall be carried out only at the time of the adjustment of the set as a whole.
2.2 Measuring instruments, jigs, and tools
The measuring instruments, jigs, and tools required at the time of the adjustment of the unit to be adjusted shall
be as specified below.
a. A signal generator that can generate an output of signal timing produced by the adjusted (*) VG-829 or
specified in [4. Setting method for the VG-829.] In this case, however, this signal generator shall be
capable of displaying all white and all black as a screen display pattern.
* The word “adjusted” shall mean that the amplitude of each signal R, G, B, which is output from the signal
generator, is maintained at 0.7Vp-p ± 0.05V when a load of 75
Ω
is connected.
b. D-SUB 15-pin signal cable
c. Video signal cable
2.3 Power-supply voltage
INPUT : 100Vac ~ 240Vac
±
10%, 47~63Hz
2.4 Aging
Not required.