(6/104)
III. Communication specification
3. Communication Parameter
3.1 RS-232C Remote control
(1) Communication system
Asynchronous
(2) Interface
RS-232C
(3) Baud rate
9600bps
(4) Data length
8bits
(5) Parity
None
(6) Stop bit
1 bit
(7) Communication code
ASCII
3.2 LAN control
(1) Communication system
TCP/IP (Internet protocol suite)
(2) Interface
Ethernet (CSMA/CD)
(3) Communication layer
Transport layer (TCP)
* Using the payload of TCP segment.
(4) IP address
(Default) Automatic setup
* If you need to change,
Please refer
“
Network settings
”
on User
’
s manual.
(5) Port No.
7142 (Fixed)
(Note)
The monitor will disconnect the connection if no packet data is received for 15 minutes.
And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or
more.
3.3 Communication timing
The controller should wait for a reply packet before the next command is sent.
(Note)
When the following commands are sent, a controller should wait for specified period after
receiving the reply command before sending the next command.
Power On, Power Off: 15 seconds
Input, Auto Setup, Factory Reset: 10 seconds