background image

English-9

English

7.  Slide down the cable cover (

Figure D.1

). 

8.  Connect one end of the power cord to the AC inlet on the back of the monitor and the other end to the power outlet.

NOTE:  

Please refer to the 

Caution

 section of this manual for proper selection of an AC power cord.

Figure D.1

9.  Turn on the monitor with power switch on the top (Portrait) or left side (Landscape) of the monitor (

Figure E.1

). Turn on the 

computer.

NOTE:  

If you have any problems, please refer to the 

Troubleshooting

 section of this Manual.

Figure E.1

Power switch

Raise and Lower Monitor Screen

The monitor may be raised or lowered in either Portrait or Landscape mode.
To raise or lower the screen, place hands on each side of the monitor and lift or lower to the desired height (

Figure RL.1

).

NOTE: 

Handle with care when raising or lowering the monitor screen.

Figure RL.1

Содержание MD211G3-R

Страница 1: ...Medical Display MD211G3 INSTALLATION MAINTENANCE GUIDE...

Страница 2: ...nit This symbol alerts the user that important literature concerning the operation and maintenance of this unit has been included Therefore it should be read carefully in order to avoid any problems P...

Страница 3: ...REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION Power Cord Important Information CAUTION Please use the power cord provided with this monitor in accordance with the table below If a power cord...

Страница 4: ...ms is not recommended if cleaning of the air intakes from dust and textile lint in regular time intervals cannot be performed by the user maximum interval six months This device is equipped with an in...

Страница 5: ...at interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and...

Страница 6: ...ot install where the monitor will be exposed to continual vibration If monitor or glass is broken do not come in contact with the liquid crystal and handle with care To prevent damage to the LCD monit...

Страница 7: ...optimum performance allow 30 minutes for the monitor to warm up Adjust the monitor height so that the top of the screen is at or slightly below eye level Your eyes should look slightly downward when...

Страница 8: ...DisplayPort cable CD ROM x 2 Power Cord 2 Quick Reference Guide USB Cable Remember to save your original box and packing material to transport or ship the monitor 1 Dual link DVI cable 2 Type and num...

Страница 9: ...nnect the DisplayPort cable to the connector of the display controller in your system Figure A 2 Figure A 1 Figure A 2 DisplayPort cable NOTE 1 Please use a DisplayPort cable with a DisplayPort logo 2...

Страница 10: ...sub monitors can be daisy chained Figure C 1 Highest Stand Position Power cord 30 Tilt Figure C 1a A Type B Type A Type B Type Sensor Port 1 DVI D Cable DisplayPort Cable USB Upstream Port USB Downst...

Страница 11: ...switch on the top Portrait or left side Landscape of the monitor Figure E 1 Turn on the computer NOTE If you have any problems please refer to the Troubleshooting section of this Manual Figure E 1 Po...

Страница 12: ...screen place hands on each side of the monitor and turn clockwise from Landscape to Portrait or counter clockwise from Portrait to Landscape Figure R 1 To rotate the OSD menu between landscape and por...

Страница 13: ...down on a desk or table with the front sensor situated off the edge Figure S 2 5 Slide the cable cover up NOTE The cable cover is not removable 6 Place hand on the back side of the monitor and lift up...

Страница 14: ...xits any OSD sub menu Exits the OSD Control menu Shows OSD menu Shows PICTURE MODE Selects the item Changes the input source Resets the OSD back to factory settings Shows the quick screen QA test patt...

Страница 15: ...URE MODE Change to a picture mode which is most suitable for the type of content that is shown You can choose one of two possible PICTURE MODES See Advanced OSD menu Tag1 PICTURE MODE page 17 and Usin...

Страница 16: ...tor will automatically return to normal mode QA TEST Provides a quick daily visual image quality check of this diagnostic monitor by just using a button on the monitor MENU Tools LANGUAGE The OSD cont...

Страница 17: ...ves a warning when there is no Horizontal or Vertical Sync After power is turned on or when there is a change of input signal the No Signal message window will appear OUT OF RANGE This function gives...

Страница 18: ...F ERROR result in is a quick indicator of the gray level quality against the ideal DICOM curve Depending on the QA standard which is used in your country different GSDF error limits may exist Please c...

Страница 19: ...m by a monitor Gamma is defined by the relationship between the signal input voltage and the resulting intensity of the monitor s light output A perfect linear device would have a Gamma of 1 0 A Gamma...

Страница 20: ...RIGHT to select FIRST When current video input signal is not present then the monitor searches for a video signal from a different video source If a video signal is supplied by the other video source...

Страница 21: ...a screen will appear indicating the OSD controls are locked out There are three types of OSD LOCK OUT OSD LOCK OUT with no control To activate the OSD Lock Out function press SELECT then RIGHT button...

Страница 22: ...y a sensor LANDSCAPE The preferred timing is fixed to landscape orientation 2048x1536 pixels PORTRAIT The preferred timing is fixed to portrait orientation 1536x2048 pixels Note If you have any proble...

Страница 23: ...l display performance Active Display Area Landscape Horiz Vert Portrait Horiz Vert 433 2 mm 17 1 inches 324 9 mm 12 8 inches 324 9 mm 12 8 inches 433 2 mm 17 1 inches USB Hub I F Port Load Current USB...

Страница 24: ...resolutions supported directly to your computer automatically optimizing display performance Intelligent Power Manager System Provides innovative power saving methods that allow the monitor to switch...

Страница 25: ...mage NOTE As with all personal display devices NEC DISPLAY SOLUTIONS recommends using a moving screen saver at regular intervals whenever the screen is idle or turning off the monitor when not in use...

Страница 26: ...pear on screen Figure A 1 When Stand Alone Calibration is executed the message window will appear Figure A 3 and the screen becomes dark for about 10 seconds Then ZERO CALIBRATION will start automatic...

Страница 27: ...S 3 Press SELECT to go to the next section To select AUTO CALIB go to step 6 To select EXPERT CALIB go to step 7 AUTO CALIB Make sure that the USB optical sensor is connected to the sensor port 6 The...

Страница 28: ...n 5 The procedure will ask for the USB optical sensor to be placed on the center of the display panel Figure C 4 Tilt the display panel approximately 5 backward and place the USB optical sensor in the...

Страница 29: ...the advanced menu page 24 2 Select GAMMA ADJUST in the MODE selection Figure 1 3 Select the target UNIFORMITY Press SELECT to go to the next section 4 Set the target LUMINANCE cd m2 Figure 2 Press SEL...

Страница 30: ...setting is 1 or 2 Please perform AMBIENT SENSOR CALIBRATION in the following cases The usage environment has changed AMBIENT SENSOR CALIBRATION requires an illuminance meter and a telescopic luminanc...

Страница 31: ...aving measured press SELECT without changing the value 6 After the CALIBRATION SUCCEEDED message appears Figure AS 4 press SELECT You can set DATE and TIME by using control keys and press SELECT 7 To...

Страница 32: ...t Signalling DPMS Standard signal is sent to the monitor the Energy Saving mode is activated The monitor enters a single Energy Saving mode Mode Power consumption LED colour Normal Operation Approx 10...

Отзывы: