background image

[079. FREEZE CONTROL] 
********************************************************************** 
Function: 
This command controls the freeze. 
 
Command: 
   01H  98H  00H  00H  01H  DATA01 CKS 
 
 

 

  Operation types 

   DATA01: 00H : Reserved 

      01H : Freeze start  

                   02H : Freeze cancel   
 
Response: At the time of a success 
   21H  98H  ID  *0H  01H  DATA01 CKS 
              
 
   
 Data Portion Contents 
   ------------------------------------------------------------------- 
   DATA01          Results 
                 00H : Normal 
                 01H : Error 
 
Response: At the time of a failure 
   A1H  98H  01H  xxH  02H  DATA01  DATA02  CKS 
                    (*1)    (*2)                      (*4)              (*3) 
 
 
 
 
097-196.WXGA MODE SETTING REQUEST 
********************************************************************** 
Function: 
This command acquires the setting of the WXGA Mode of projector. 
 
Command: 
   03H  B0H  00H  00H  01H  C3H  77H 
 
Response: At the time of a success 
   23H  B0H  01H  xxH  02H  DATA01  DATA02  CKS 
             (*1) (*2)                      (*3) 
 
   Data Portion     Contents 
   ----------------------------------------------------------------- 
   DATA01             C3H fixed 
   DATA02           Setting Value 
                      00H : OFF 
                      01H : ON 
 
Response: At the time of a failure 
   A3H  B0H  01H  xxH  02H  DATA01  DATA02  CKS 
             (*1) (*2)           (*4)       (*3) 
 
 
 
 
097-198. PIP/SIDE BY SIDE REQUEST 
********************************************************************** 
Function: 
This command acquires the setting of the PIP/SIDE BY SIDE of projector. 
 

Содержание GT5000 - XGA LCD Projector

Страница 1: ...es NP600 NP300 NP400 NP500 NP500W NP500WS NP600 NP600S Series VT VT770 Series VT70 VT37 VT47 VT480 VT57 VT570 VT575 VT670 VT676 Series VT80 VT48 VT480 VT580 Series VT90 VT49 VT490 VT590 VT595 VT695 Se...

Страница 2: ...sing the USB port on the projector A USB cable is required 3 LAN connection 3 1 LAN connection using a wired LAN card A wired LAN card and LAN cable are required 3 2 LAN connection using a wireless LA...

Страница 3: ...o No VT48 VT480 VT580 Yes No No No No No VT49 VT490 VT590 VT595 VT695 VT700 Yes No No No No No VT700 Yes No No No No No VT800 Yes No No No Yes No WT600WT 610 WT615 Yes Yes Yes Yes No No NP4000 NP4001...

Страница 4: ...Only the M300 series is compatible P350X P350W P420X Series STANDBY MODE POWER SAVING Control Command Serial port Wired LAN port Wireless LAN unit POWER ON Yes No No Yes Supported No Not supported 3 I...

Страница 5: ...edge hereafter referred to as ACK that recognizes a command and Negative Acknowledge hereafter referred to as NAK that fails to recognize a command Command Controller Projector Response ACK or NAK 4 1...

Страница 6: ...one basis Broadcast notification is recommended When the controller is connected with multiple projectors To control a certain projector use individual notification For all others broadcast notificati...

Страница 7: ...it This is data length of data portion unit byte Command This sets data length of data added to a command to send it See each command description Response This sets data length of data added to a resp...

Страница 8: ...compatible with the PC Viewer When a parameter error occurs 00H Unvalid values specified 01H Specified terminal is unavailable or cannot be selected 02H Selected language is not available When an oper...

Страница 9: ...sing a USB hub please use a self powered type not a bus powered type When using a USB hub connection to the first stage of the USB hub is recommended LAN connection Wired LAN port LAN interface Commun...

Страница 10: ...03H B1H 00H 00H 02H 07H 00H BDH 046 WXGA MODE SETTING REQUEST 03H B0H 00H 00H 01H DATA1 CKS 049 WXGA MODE SETTING SET 03H B1H 00H 00H 02H DATA1 DATA2 CKS 050 REMOTE KEY CODE 02H 0FH 00H 00H 02H 00H 00...

Страница 11: ...14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 006 RUNNING SENSE 007 COMMON DATA REQUEST 009 ERROR STATUS REQUEST 015 POWER ON 016 POWER OFF 018 INPUT SW CHANGE 020 PICTURE MUTE...

Страница 12: ...In case of NP60 series D0H In case of NP4000 4100 series 80H In case of NP905 NP901W VT800 90H 3 Checksum CKS inscription This is the value of the lower 8 bits of the results calculated in byte units...

Страница 13: ...During execution Bit 6 Selecting signal processing 0 No execution Normal condition 1 During execution Bit 5 Cooling processing 0 No execution Normal condition 1 During execution Bit 4 External contro...

Страница 14: ...During execution DATA06 Indication signal number Entry list number 1 0 199 DATA07 Type 1 of input terminal to be selected 1 01H 1 02H 2 03H 3 04H 4 05H 5 DATA08 Type 2 of input terminal to be selected...

Страница 15: ...LT180 LT80 HT GT WT VT NP1000 NP3150 NP905 NP4000 NP4100 NP62 NP64 NP3250 NP216 02H Cross Hatch x x x x x x 03H Gray Bars x x x x X 04H Raster 0 05H Raster 25 x x 06H Raster 50 x x 07H Raster 100 08H...

Страница 16: ...ing DATA68 Selecting signal processing 00H No execution Normal condition 01H During execution DATA69 Status of operation 00H Idling 04H Power On 05H Cooling 06H Idling Error occurrence Other than abov...

Страница 17: ...10H 00H 08H VT700 10H 00H 09H NP600 10H 01H 09H NP500 10H 02H 09H NP500 W 10H 03H 09H NP400 10H 04H 09H NP300 10H 00H 10H NP610 10H 01H 10H NP510 10H 02H 10H NP510W 10H 03H 10H NP410 10H 05H 10H NP310...

Страница 18: ...f a failure A0H C0H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 1 VT700 NP600 series Selected input terminal Data 07 Data08 RGB or RGB1 5 1 01H RGB 01H RGB2 5 2 02H RGB 01H Video 1 01H VIDEO 02H S Video 1 0...

Страница 19: ...ife DATA02 Error Status 2 bit0 Lamp or Lamp1 has been used beyond its limit bit1 Formatter error bit2 Lamp2 error bit3 None bit4 None bit5 None bit6 None bit7 None DATA03 Error Status 3 bit0 None bit1...

Страница 20: ...OFF Function This command switches off the main power of the projector Command 02H 01H 00H 00H 00H 03H Response At the time of a success 22H 01H 01H xxH 00H CKS 1 2 3 Response At the time of a failure...

Страница 21: ...0 LT280 does not support a DVI connector HT1000 HT410 HT510 HT1100 VT770 support Component and Viewer 1 VT470 VT470JY VT570 VT670 VT575 VT676 VT480 VT580 2 VT595 VT695 VT700 NP300 NP400 NP500 NP500W N...

Страница 22: ...2 4 3 022 SOUND MUTE ON Function This command mutes the sound Command 02H 12H 00H 00H 00H 14H Response At the time of a success 22H 12H 01H xxH 00H CKS 1 2 3 Response At the time of a failure A2H 12H...

Страница 23: ...witching 025 ONSCREEN MUTE OFF Function This command cancels the blanking of the on screen display Command 02H 15H 00H 00H 00H 17H Response At the time of a success 22H 15H 01H xxH 00H CKS 1 2 3 Respo...

Страница 24: ...e 00H Volume only DATA03 00H direct settings 01H increment decrement DATA04 lower data 8bit DATA05 upper data 8bit ex 1 volume direct setting value 20 DATA01 05H Volume DATA02 00H Volume only DATA03 0...

Страница 25: ...1 DATA02 CKS 1 2 3 Data Portion Contents DATA01 02 Results 0000H Normal 0000H Other Error Response At the time of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Command example Setting Volume...

Страница 26: ...00H Aspect Ratio 1 78 1 16 9 02H 00H Aspect Ratio Cinema 16 9 NP600 NP610 NP2200 NP62 NP64 NP215 P420 Series 02H 00H Aspect Ratio Crop 03H 00H Aspect Ratio Wide Zoom NP4000 Series NP4100 Series 03H 00...

Страница 27: ...ion Examples DATA83 DATA84 DATA85 DATA86 Lamp Timer 00H 00H 00H 00H Total 0 seconds C0H 65H 52H 00H Total 5400000 seconds 3600 1500 hours 00H E4H 57H 00H Total 5760000 seconds 3600 1600 hours Calculat...

Страница 28: ...onds Starting time for lamp usage warning message in terms of Normal mode values DATA09 DATA10 DATA11 DATA12 00H DDH 6DH 00H 7200000 second Calculator Procedure 1 Set calculator to HEX 2 Punch in DATA...

Страница 29: ...values 10H Remaining time until inhibition of lamp usage in terms of specified values 11H Remaining time until inhibition of lamp usage in terms of Normal mode values 12H Remaining time until inhibiti...

Страница 30: ...4 Function This command acquires the information on the projector lamp Command 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS 3 Data Portion Contents DATA01 Target 00H Lamp1 01H Lamp2 DATA02 Unit 4 00H...

Страница 31: ...ime 100 Lamp Use Warning Starting Time Example The case of Lamp Use Prohibited Time 2100 H A Lamp Use Warning Starting Time 2000 H Model X 100 2100 100 2000 5 2 Lamp Hour Meter This is the timer for n...

Страница 32: ...A01 07H fixed DATA02 Results 00H Normal 01H Error Response At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 046 WXGA MODE SETTING REQUEST Function This command acquires the setti...

Страница 33: ...mal 01H Error Response At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 6 Response At the time of a success ACK This returns ACK without adding data portion to the command that d...

Страница 34: ...te control key code Word type Key number DATA01 DATA02 Key name 1 01H 00H POWER 2 02H 00H POWER ON 3 03H 00H POWER OFF 4 04H 00H SOURCE AUTO 5 05H 00H AUTO 6 06H 00H MENU 7 07H 00H UP 8 08H 00H DOWN 9...

Страница 35: ...DIGITAL1 84 54H 00H DIGITAL2 85 55H 00H PC CARD 96 60H 00H BS 132 84H 00H VOLUME UP 133 85H 00H VOLUME DOWN 134 86H 00H KEYSTONE UP 135 87H 00H KEYSTONE DOWN 136 88H 00H SLIDE UP 137 89H 00H SLIDE DO...

Страница 36: ...series and NP4000 series VT60 series VT70 series VT80 series and VT90 series Command example Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H Sending the AUTO SHORT key code 02H 0FH 00H 00H...

Страница 37: ...Data Portion Contents DATA01 Same as DATA01 of the transmit data DATA02 to 05 Carbon Savings Kilogram Maximum 99999 kg DATA06 to 09 Carbon Savings Milligram Maximum 999999 mg Response At the time of a...

Страница 38: ...ustment possible FFH Selected gain is not available DATA02 Maximum adjustment value Lower ranking 8 bits DATA03 Maximum adjustment value Upper ranking 8 bits DATA04 Minimum adjustment value Lower rank...

Страница 39: ...Black Correct Position 2CH 01H Black Correct Gain 2CH 02H Black Correct Inv Gain 2DH 00H Lamp Output 2EH 00H Signal Level Auto Control 2FH 00H Signal Level R G B Gain R 2FH 01H Signal Level R G B Gain...

Страница 40: ...ce 62H 00H Digital Zoom Zoom 62H 01H Digital Zoom Horizontal Position 62H 02H Digital Zoom Vertical Position 63H 00H White Bal Dual Brightness R 63H 01H White Bal Dual Brightness G 63H 02H White Bal D...

Страница 41: ...2 3 Data Portion Contents DATA01 Results 00H Normal 01H Error Response At the time of a failure A2H 1AH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Supplement Sound mute is cancelled in the following cases...

Страница 42: ...10H 01H 09H NP500 10H 02H 09H NP500 W 10H 03H 09H NP400 10H 04H 09H NP300 10H 00H 10H NP610 10H 01H 10H NP510 10H 02H 10H NP510W 10H 03H 10H NP410 10H 05H 10H NP310 10H 07H 10H NP610S 10H 08H 10H NP5...

Страница 43: ...nse At the time of a success 20H 85H 01H xxH 10H DATA01 DATA16 CKS 1 2 3 Data Portion Contents DATA01 02 Reserved DATA03 Projector status 00H Idling 01H Power On DATA04 Cooling processing 00H No execu...

Страница 44: ...tents DATA01 Selecting signal processing 00H No execution Normal condition 01H During execution DATA02 Signal number Entry list number 1 0 199 DATA03 04 Selected input terminal Terminal name DATA03 DA...

Страница 45: ...078 4 MUTE STATUS REQUEST Function This command acquires the status of the mute of projector Command 00H 85H 00H 00H 01H 03H 89H Response At the time of a success 20H 85H 01H xxH 10H DATA01 DATA16 CKS...

Страница 46: ...not available 02H 00H Available memory reservation error 02H 02H Operating memory 02H 03H Setting not possible 02H 04H On Forced on screen mute mode 02H 06H 02H 07H No signal 02H 08H 02H 09H No PC car...

Страница 47: ...98H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 097 196 WXGA MODE SETTING REQUEST Function This command acquires the setting of the WXGA Mode of projector Command 03H B0H 00H 00H 01H C3H 77H Response At the...

Страница 48: ...E BY SIDE if DATA02 is POSITION 01H 00H TOP LEFT 01H TOP RIGHT 02H BOTTOM LEFT 03H BOTTOM RIGHT if DATA02 is SOURCE 02H 00H OFF 01H VIDEO 02H S VIDEO Response At the time of a failure A3H B0H 01H xxH...

Страница 49: ...A3H B1H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 110 AUTO FUNCTIONS EXECUTE Function This command executes the auto functions Command 03H B6H 00H 00H 01H DATA01 CKS 3 Data Portion Contents DATA01 Executi...

Страница 50: ...ilure A3H BAH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 305 1 BASE MODEL TYPE REQUEST Function This command acquires the projector type Command 00H BFH 00H 00H 01H 00H C0H Response At the time of a succes...

Страница 51: ...03H 08H 01H 10H NP4100W 01H 10H 00H 08H VT700 FFH 10H 00H 09H NP600 FFH 10H 01H 09H NP500 FFH 10H 02H 09H NP500W FFH 10H 03H 09H NP400 FFH 10H 04H 09H NP300 FFH 10H 00H 10H NP610 FFH 10H 01H 10H NP510...

Страница 52: ...Idle 04H Power On 05H Cooling 06H Idle Error Standby Other Not Support Other than above nondisclosure Internal use of code during a state transition period DATA03 Indicate Contents 00H Picture signal...

Страница 53: ...put Other Not Support DATA07 Picture Mute 00H OFF 01H ON DATA08 Sound Mute 00H OFF 01H ON DATA09 On screen mute 00H OFF 01H ON DATA10 DATA16 Reserved Response At the time of a failure A0H BFH 01H xxH...

Страница 54: ...ible 02H 04H On Forced on screen mute mode 02H 07H No signal 02H 08H 02H 0AH Memory operation failed 02H 0DH Power Off inhibited 02H 0EH Execution error 02H 0FH No operation authority 03H 00H Specifie...

Отзывы: