SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/T120g
NEC Corporation
Revision 5.0
– February, 2017
19
4.2.8
3.5-inch Drive Cage with RAID 0/1 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
LSI MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, 12Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
N8103-181
Drive Cage/
Cable
1 to 2 Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug hard drive bays
Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable
N8154-78F
NOTE:
For supported HDD/SSD, refer to
4.3.8
for Windows Server 2008R2 or VMware.
Refer to
4.3.9
for Windows Server 2012/2012R2,
Red Hat Enterprise Linux 6 or Red Hat Enterprise Linux 7.
All drives within a RAID array should be of the same capacity.
4.2.9
3.5-inch Drive Cage with RAID 5/6 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
N8103-177
Flash Backup
Recommended
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
N8103-181
Drive Cage/
Cable
1 to 2 Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug hard drive bays
Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable
N8154-78F
NOTE:
For supported HDD/SSD, refer to
4.3.8
for Windows Server 2008R2 or VMware.
Refer to
4.3.9
for Windows Server 2012/2012R2,
Red Hat Enterprise Linux 6 or Red Hat Enterprise Linux 7.
All drives within a RAID array should be of the same capacity.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.
4.2.10 3.5-inch Drive Cages with RAID 5/6 Controller with 2 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, 12Gb/s
N8103-178
Flash Backup
Recommended
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
N8103-181
Drive Cage/
Cable
1 to 2 Required
3.5-inch Drive Cage
4 x 3.5-inch hot plug hard drive bays
Including 1 sets of 1 x Mini SAS HD to 1 x Mini SAS HD cable
N8154-78F
NOTE:
For supported HDD/SSD, refer to
4.3.8
for Windows Server 2008R2 or VMware.
Refer to
4.3.9
for Windows Server 2012/2012R2,
Red Hat Enterprise Linux 6 or Red Hat Enterprise Linux 7.
All drives within a RAID array should be of the same capacity.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of
becoming multiple hard drives failure during the RAID rebuilding process.