background image

SYSTEM CONFIGRATION GUIDE

 

– 

NEC Express5800/T110g-E 

NEC Corporation 

Revision 5.0 

– April 17, 2015 

29

 

 

To  use Windows  BitLocker  drive  encryption,  be  sure  to  keep  the  "recovery  password"  of  BitLocker 
function.  The  recovery  password  is  required  to  restore  data  for  hardware  replacement  during  a 
system error. 

8.3 

Internal Flash Memory 

Product Name / Description 

Part Number 

Internal Flash Memory 

Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without 
DVD media 

NOTE: 

Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the 
flash memory. 

The following operations can be performed with the flash memory: 

Installation of Windows server with express setup 

Installation of Starter Pack

—the package of NEC qualified drivers and system setting 

tools 

Installation of NEC ESMPRO Agent and Universal RAID Utility 

Performance of the Test and Diagnosis Tool 

N8115-14 

8.4 

Flash FDD 

Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. 

Product Name / Description 

Part Number 

Flash FDD 

USB flash emulating USB floppy disk, Native capacity 1.44 MB 

N8160-96 

NOTE: 

 

Up to one derive can be connected 

8.5 

Input Devices 

Product Name / Description 

Part Number 

Keyboard and Mouse Pack (US) 

1 x 104-keys White USB keyboard, 1 x USB White Optical Wheel Mouse 

(Standard  in  some 
models) 

NOTE: 

 

For keyboard and mouse packs not listed above, contact your sales representative. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Express5800/T110g-E

Страница 1: ...ide Introduction This document contains product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server April 17 2015 Revision 5 0 NEC Corporation ...

Страница 2: ...figuration 23 5 Internal Optical Drive 25 6 Internal RDX LTO Drives 26 6 1 RDX LTO Drive Selection 26 6 2 RDX LTO Configuration 26 7 PCI Card 27 7 1 Network Interface Controller 27 7 2 SAS Controller 28 7 3 Serial Port Adapter 28 8 Other Add in Components 28 8 1 Redundant Power Supply Module 28 8 2 Trusted Platform Module Kit 28 8 3 Internal Flash Memory 29 8 4 Flash FDD 29 8 5 Input Devices 29 9 ...

Страница 3: ...fered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB 4 x 8 GB Internal Storage Standard Capacity 0 GB Maximum Capacity 16 TB 4 x 4 TB Disk Controller SATA 6Gb s Integrated RAID SATA RAID 0 1 10 Standard RAID 5 6 50 60 Optional SAS RAID 0 1 5 6 10 50 60 Optional Hot Plug Supported with hot plug drive bay Optical Disk Drive Optional 5 inch Media Bays 2 Disk Drive Bays Hot plug 2 5 inch drive con...

Страница 4: ...crosoft Windows Server 2008 R2 Enterprise Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter Red Hat Enterprise Linux 5 10 or later 4 Red Hat Enterprise Linux 5 10 or later EM64T 4 Red Hat Enterprise Linux 6 5 or later 4 Red Hat Enterprise Linux 6 5 or later EM64T 4 Red Hat Enterprise...

Страница 5: ...front 2 rear 1 internal 4 USB2 0 1 front 2 rear 1 internal 2 1000BASE T LAN connector RJ 45 2 rear 1 100BASE TX LAN connector for Management RJ 45 1 rear Server Management EXPRESSSCOPE Engine 3 System Fan Standard Power Supply 1 x 400 Watt 80 PLUS Gold certified non hot plug PSU 1 2 x 450 Watt 80 PLUS Platinum certified Hot plug PSU 100 240 VAC 10 50 60 Hz 3 Hz Power Consumption Max Config Idling ...

Страница 6: ... Linux 6 5 or later EM64T 4 Red Hat Enterprise Linux 7 0 or later 4 VMware ESXi 5 1 Update 1 or later VMware ESXi 5 5 Update 1 VMware ESXi 6 0 1 Embedded SATA RAID controller is supported only on limited OS 2 Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 65K colors 3 Noise emission was measured in accordance with ISO 7779 The actual value may vary by the oper...

Страница 7: ...uration Hot Plug 3 5 inch Drive Configuration Non hot Plug 3 5 inch Drive Configuration Legend A Power Button G Drive Bay Cover Key B Power LED H Drive Bay Cover C Hard Drive Activity LED I 5 25 inch Media Bay 2 D System Status LED J 5 25 inch Media Bay 1 E USB 3 0 Connector K Optical Disk Drive F USB 2 0 Connector F USB 2 0 Connector A D C B H E F G K J I K J I K J I ...

Страница 8: ...s Hot Plug Power Supply Configuration Non hot Plug Power Supply Configuration Legend A Serial Port A Connector F USB 3 0 Connectors B VGA Connector G Management LAN Connector C BMC Reset Switch H LAN Connectors D Dump NMI Switch I PCI Slots Full Height E USB 2 0 Connectors J AC Inlet D C B A J E F G H I J ...

Страница 9: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 T110g E NEC Corporation Revision 5 0 April 17 2015 9 Dimensions mm Standard Bezel Non redundant Power Configuration Redundant Power Configuration ...

Страница 10: ... Standard components Mandatory components Expansion Slots Legend 1 PCIe 2 0 x1 x8 connector Full Height up to 168mm length 2 PCIe 2 0 x1 x8 connector Full Height up to 168mm length 3 PCIe 3 0 x16 x16 connector Full Height up to 312mm length 4 PCIe 2 0 x4 x8 connector Full Height up to 168mm length Slot 4 Slot 3 Slot 2 Slot 1 ...

Страница 11: ...ory Product Name Description Part Number Processors Required Celeron G1840 Processor Kit Intel Celeron Processor G1840 2 80 GHz 2C 2T 2 MB N8101 737F Pentium G3240 Processor Kit Intel Pentium Processor G3240 3 10 GHz 2C 2T 3 MB N8101 738F Core i3 4350 Processor Kit Intel Core i3 4350 Processor 3 60GHz 2C 4T 4 MB N8101 739F Xeon E3 1220 v3 Processor Kit Intel Xeon Processor E3 1220 v3 3 10 GHz 4C 4...

Страница 12: ...Microsoft Windows Server 2008 Standard 4 GB 4 GB HW DEP enabled App 3 5 GB HW DEP disabled Microsoft Windows Server 2008 R2 Standard 1 32 GB 32 GB Microsoft Windows Server 2008 Enterprise 64 GB 32 GB Microsoft Windows Server 2008 R2 Enterprise 1 2 TB 32 GB Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windo...

Страница 13: ...ed in a system All drives within a RAID array should be of the same capacity and rotation speed 4 1 2 Hot plug 3 5 inch Drive Non RAID RAID 5 6 50 60 0 MB Cache 1GB Cache Battery 512 MB Cache Refer to 4 2 1 Refer to 4 2 3 Refer to 4 2 5 Refer to 4 2 6 RAID 0 1 SATA SAS SATA SAS SATA SAS SATA Available Interface Embedded SATA RAID Controller Optional RAID Controller Refer to 4 2 2 SATA 512 MB Cache...

Страница 14: ...me capacity and rotation speed 4 2 2 5 inch Drive Configuration 4 2 1 Embedded SATA non RAID Controller Category Product Name Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb s SATA Standard Cable Internal SATA Cable Mini SAS to mini SAS Standard Drive Cage Required 2 5 inch Drive Cage 8 x 2 5 inch hot plug drive bays N8154 55F Drive 4 slots available SATA HDD 250GB 7 2K ...

Страница 15: ...AID Controller 0MB RAID 0 1 LSI MegaRAID SAS 9240 8i RAID0 1 10 no memory cache Int 8 PCIe 2 0 x8 SAS 6Gb s SATA 6Gb s N8103 171 Cable Internal SATA Cable Mini SAS to mini SAS Standard Internal SAS SATA Cable Mini SAS to mini SAS for 5th 8th hard drives K410 294 00 Drive Cage Required 2 5 inch Drive Cage 8 x 2 5 inch hot plug drive bays N8154 55F Drive 8 slots available SAS HDD 300GB HDD 1x 300 GB...

Страница 16: ...1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 445 600GB HDD 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 450 450GB HDD 1x 450 GB SA...

Страница 17: ... 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 450 450GB HDD 1x 450 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 451 600GB HDD 1x 600 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 522 SATA HDD 250GB 7 2K Hot Plug 2 5 inch SATA HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm N8150 452 50...

Страница 18: ...00 rpm N8150 450 450GB HDD 1x 450 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 451 600GB HDD 1x 600 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 522 SATA HDD 250GB 7 2K Hot Plug 2 5 inch SATA HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm N8150 452 500GB 7 2K Hot Plug 2 5 inch SATA HDD 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm N8150 453 1TB 7 2K Hot Plug 2 5 inch SATA HDD 1x 1 TB SATA HDD 2 5 inch ...

Страница 19: ...15 000 rpm N8150 451 600GB HDD 1x 600 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 522 SATA HDD 250GB 7 2K Hot Plug 2 5 inch SATA HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm N8150 452 500GB 7 2K Hot Plug 2 5 inch SATA HDD 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm N8150 453 1TB 7 2K Hot Plug 2 5 inch SATA HDD 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm N8150 454 SAS SSD 200GB Hot Plug 2 5 inch SA...

Страница 20: ...m N8150 458 4TB 7 2K Hot Plug 3 5 inch SATA HDD 1 x 4 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 459 NOTE Embedded SATA RAID controller is supported only on limited OS For more details please see OS Support Matrix for PCI Cards and Embedded Controllers All hard drives within a RAID array should be of the same capacity Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or mo...

Страница 21: ... SATA HDD 1 x 4 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 459 NOTE All hard drives within a RAID array should be of the same capacity 4 3 5 RAID 5 6 Controller with 512 MB Cache Category Product Name Description Part Number Storage Controller Required RAID Controller 512MB RAID 0 1 5 6 LSI MegaRAID SAS 9272 8i RAID0 1 5 6 10 50 60 512 MB Int 8 PCIe 3 0 x8 SAS 6Gb s SATA 6Gb s N8103 173 RAID BBU R...

Страница 22: ... HDD 3 5 inch 6Gb s 7 200 rpm N8150 459 NOTE All hard drives within a RAID array should be of the same capacity 4 3 7 RAID 5 6 Controller with 1GB Cache CacheVault Category Product Name Description Part Number Storage Controller Required RAID Controller 1GB RAID 0 1 5 6 LSI MegaRAID SAS 9270CV 8i with CV RAID0 1 5 6 10 50 60 1GB Cache Int 8ports PCIe 3 0 x8 6Gb s flash cache protection modules inc...

Страница 23: ...nch Drive Cage 4 x 3 5 inch non hot plug drive bays N8154 53F Drive 4 slots available 500GB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 460 1TB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 1 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 461 2TB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 2 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 462 3TB 7 2K non Hot Plug 3 5 inch ...

Страница 24: ...n hot plug drive bays N8154 53F Drive 4 slots available 500GB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 460 1TB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 1 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 461 2TB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 2 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 462 3TB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 3 TB SATA HDD 3 5...

Страница 25: ... for LSI MegaRAID SAS 9272 8i N8103 155 Cable Required RAID LED Cable K410 293 00 Cable Internal SAS SATA Cable miniSAS to 4x SingleSATA Standard Drive Cage Required 3 5 inch Drive Cage 4 x 3 5 inch non hot plug drive bays N8154 53F Drive 4 slots available 500GB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 460 1TB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 1 ...

Страница 26: ...x Internal USB3 0 to 1x USB 3 0 device K410 276 00 Drive 1 bays available Internal RDX USB N8151 105 NOTE The USB bus operates in USB 2 0 mode if the system is running with Windows Server 2008 or Red Hat Enterprise Linux 5 operating system 6 2 2 LTO Drive Category Product Name Description Part Number Controller Required SAS Controller LSI SAS9212 4i4e Host Bus Adapter 6Gbps SAS Int 4 Ext 4 7 pin S...

Страница 27: ...up to 2 adapters covering 10Gb Converged Network Adapter and 10Gb Network Adapter N8104 128 Module SFP Module 10G SR 1 x SFP Module for N8104 128 N8104 129 NIC Teaming feature NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations Windows Server 2008 support BASP Broadcom Advanced Server Program or Intel PROSet teaming while Windows Server 2012 or...

Страница 28: ...indows Server 2008 R2 Windows Serer 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 VMware NOTE NIC Teaming feature is not supported on iSCSI interfaces 7 2 SAS Controller Product Name Description Part Number SAS Controller LSI SAS9212 4i4e Host Bus Adapter 6Gb s SAS Int 4 Ext 4 7 pin SATA SFF 8088 PCIe 2 0 x8 N8103 142 7 3 Serial Port Adapter Product Name Descrip...

Страница 29: ...n be performed with the flash memory Installation of Windows server with express setup Installation of Starter Pack the package of NEC qualified drivers and system setting tools Installation of NEC ESMPRO Agent and Universal RAID Utility Performance of the Test and Diagnosis Tool N8115 14 8 4 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive Product Nam...

Страница 30: ...cessing the local drives N8115 04 NOTE Remote KVM and remote media features are not available for virtual machines 9 2 Rack Conversion Kit Product Name Description Part Number Rack Conversion Kit Convert to 4U form factor N8143 93 9 3 Dust Proof Kit The server supports the dust resistant feature Choose the following kit to install the system in dusty places Category Product Name Description Part N...

Страница 31: ...sole Remote Screen Video Capture Remote control via LAN Remote reset power on off dump Remote Power Capping BIOS BMC FW update Remote BIOS setup partial configuration only OS shutdown 3 3 Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Scheduling without UPS require NEC ESMPRO Manager 3 3 Maintenance EXPRESSSCOPE ...

Страница 32: ... 6 N8103 174 RAID Controller 1GB RAID 0 1 5 6 N8103 168 RAID Controller 1GB RAID 0 1 5 6 N8104 138 1000BASE T adapter N8104 132 Dual Port 1000BASE T Adapter N8104 133 Quad Port 1000BASE T Adapter N8104 128 10GBASE Adapter SFP 2ch Supported PCI cards and Installable Slots Slots Part Number Product Name 1 2 3 4 N8103 142 SAS Controller N8103 171 RAID Controller 0MB RAID 0 1 N8103 172 RAID Controller...

Страница 33: ... trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for technical or editorial errors or o...

Страница 34: ...pported 4 0 January 28 2015 Part number changed Flash FDD N8160 96 3 0 November 21 2014 Discontinued product deleted 2GB DDR3L 1600 UNB Memory Kit N8102 523F 2 0 October 16 2014 Discontinued product deleted RDX Cartridge 1 5TB N8153 04 Others Add Red Hat Linux 7 to the list of operating system supported Update OS support matrix 1 1 July 24 2014 Other Added a note for N8104 133 1 0 July 18 2014 Ini...