1. Bundled Software for the Server
Express5800/R320e-E4, R320e-M4, R320f-E4, R320f-M4 Installation Guide (VMware)
77
Chapter 2 Installing Bundled Software
1.1.1
Preinclination
SNMP is used for reporting to NEC ESMPRO Manager. Provide settings for SNMP as shown below.
1.
Log in to ftSys Management Appliance as a root user.
2.
Edit the /etc/snmp/snmpd.conf.
Change the /etc/snmp/snmpd.conf, and, for ESMPRO MIB (.1.3.6.1.4.1.119.2.2.4.4), set a right of the
community in "READ WRITE".
In the example below, "READ WRITE" authority is given to all MIB (.1 subordinates) of default
community (public).
Example
Note
Refer to Help of snmpd.conf for detailed procedure. Run man command to open Help of
snmpd.conf.
3.
Check that enabled of snmpd.
# systemctl is-enabled snmpd.service
- In case of enabled, restart snmpd.
# systemctl restart snmpd.service
- In case of disabled, change the setting of snmpd, and start snmpd.
# systemctl enable snmpd.service
# systemctl start snmpd.service
4.
Allow to receive the snmp/udp port on the ft management appliance.
# firewall-cmd --permanent --add-rich-rule='rule family="ipv4" port
port="161" protocol="udp" accept'
# firewall-cmd --reload
####
# Third, create a view for us to let the group have rights to:
# name incl/excl subtree mask(optional)
#view systemview included .1.3.6.1.2.1.1
#view systemview included .1.3.6.1.2.1.25.1.1
view all included .1 80
####
# Finally, grant the group read-only access to the systemview view.
# group context sec.model sec.level prefix read write notif
#access notConfigGroup "" any noauth exact systemview none none
access notConfigGroup "" any noauth exact all all none
enabled
Modify these lines.
– Comment out the existing
description.
– Add new descriptions.
Содержание Express5800/R320f-E4