SYSTEM CONFIGURATION GUIDE
–
NEC Express5800R120f-1E
NEC Corporation
Revision 6.0
– July 16, 2015
15
4.2.2 Up to four Drives with embedded SATA RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
(Standard)
Cable
Internal SATA Cable
1 x mini-SAS HD to 1 x mini-SAS HD, 1 set
(Standard)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
(Standard)
NOTE:
Supported up to 4x SATA HDD.
For supported HDD, refer to
4.3.2
4.2.3 RAID 0/1 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
LSI MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, 12Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Optional Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
NOTE: To install five drives or more, optional cable is
required.
K410-324(00)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
(Standard)
NOTE:
For Supported HDD/SSD, refer to
4.3.3
for Windows Server 2008/2008R2, Red Hat Enterprise Linux
6, Red Hat Enterprise Linux 6(x86_64) with KVM feature, or VMware.
Refer to
4.3.4
for Windows
Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature, or Red Hat
Enterprise Linux 7.
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SATA SSD and
SAS SSDs can be mixed.
4.2.4 RAID 5/6 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
N8103-177
Flash Backup
Recommended
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
(Standard)
Optional Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
NOTE: To install five drives or more, optional cable is
required.
K410-324(00)