Notices and Restrictions 

 

 

 

 

Express5800/120Rg-2 

Notices and Restrictions 

 
 
 
 
 
 

 

This document describes the restrictions on Express5800/120Rg-2.  

Please read the list of notices 

below carefully to ensure that they are followed.  

 

 

List of Notices 

 Notices 

Models 

Note when using Remote Management Card (N8115-01, N8115-02) 

  When using modem for Express Report Service, use serial port A.

 

<supplement> 
When using serial port B (for example UPS), do the setting as below; 

 

In EXPRESSBUILDER menu, ”System Management Function” ->”System 
Management Setting” ->”Configuration” ->”Change”->”Common” 

   Set “Alert” and “Remote Control (WAN/Direct)” as “Disable”. 
   (Default setting is “Disable”.) 

Note for Seamless set up with SCSI HostRAID (On-Board RAID) 
Configuration 

Installation procedure is as follows  
(1)

 

When SCSI back up device is connected, take off cable connection. 

(2)

 

Start “SCSI Select™ Utility” menu in POST, set the HostRAID function on 
both of SCSI A/B as “Enable”, and do the installation. 
* Refer to the User’s Guide for how to set the HostRAID function. 

(3)

 

After finishing installation, connect back up device with cable. 

(4)

 

Start “SCSI Select™ Utility” menu in POST, set the HostRAID function on the 
channel which is connected to the SCSI back up device as “disable”.   
* Refer to the User’s Guide for HostRAID setting. 

Note when using HostRAID configuration on Windows 2000 Advanced Server 
+ SP4 (if procured, installed, and supported by customer) 

   Memory capacity should be 6GB or less. (6GB is supported.) 

120Rg-2 

Note when using LAN for Management 

  When using LAN for Management, for example Wake On LAN or the alert 

function via LAN using Remote Management Card, use LAN#1 port. LAN#2 
port should not be used as LAN for management. 

120Rg-2 

 

 If you have any questions about this document, please contact your sales representative. 

 

4  Express5800/120Rg-2 System Release Notes 