9-40 Upgrading Your Server
14.
Put the heat sink on CPU and fix the heat sink with four screws.
NOTE:
Be aware of direction of heat sink (see figure below).
15.
Make sure that the heat sink is level.
NOTES:
If the heat sink is not level, remove it, and then install it again. The
following probably causes the heat sink not to be level:
– The CPU is not positioned correctly.
– All screws are not completely tightened.
Do not move the secured heat sink.
Processor 1
Processor 2
(1)
(2)
(3)
(4)